11 research outputs found

    Regarding “Graft patency is not the only clinical predictor of success after exclusion and bypass of popliteal artery aneurysms”

    Get PDF

    Morphology Of Current Of Injury Does Not Predict Long Term Active Fixation ICD Lead Performance

    Get PDF
    Background: Currents of injury (COI) have been associated with improved lead performance during perioperative measurements in pacemaker and ICD implants. Their relevance on long term lead stability remains unclear.Methods: Unipolar signals were recorded immediately after active fixation ICD lead positioning, blinded to the implanting surgeon. Signals were assigned to prespecified COI types by two independent investigators. Sensing, pacing as well as changes requiring surgical intervention were prospectively investigated for 3 months.Results: 105 consecutive ICD lead implants were studied. All could be assigned to a particular COI with 48 type 1, 43 type 2 and 14 type 3 signals. Pacing impedance at implant was 703.8±151.6 Ohm with a significant COI independent drop within the first week. Sensing was 10.6mV± 3.7mV and pacing threshold at implant was 0.8±0.3mV at 0.5ms at implant. There was no significant difference between COI groups at implant and during a 3 months follow up regarding sensing, pacing nor surgical revisions.Conclusions: Three distinct patterns of unipolar endocardial potentials were observed in active fixation ICD lead implant, but COI morphology did not predict lead performance after 3 months

    Practice of neuromonitoring in open and endovascular thoracoabdominal aortic repair—an international expert-based modified Delphi consensus study

    Full text link
    OBJECTIVES: Spinal cord injury is detrimental for patients undergoing open or endovascular thoracoabdominal aortic aneurysm (TAAA) repair. The aim of this survey and of the modified Delphi consensus was to gather information on current practices and standards in neuroprotection in patients undergoing open and endovascular TAAA.METHODS: The Aortic Association conducted an international online survey on neuromonitoring in open and endovascular TAAA repair. In a first round an expert panel put together a survey on different aspects of neuromonitoring. Based on the answers from the first round of the survey, 18 Delphi consensus questions were formulated.RESULTS: A total of 56 physicians completed the survey. Of these, 45 perform open and endovascular TAAA repair, 3 do open TAAA repair and 8 do endovascular TAAA repair. At least 1 neuromonitoring or protection modality is utilized during open TAAA surgery. Cerebrospinal fluid (CSF) drainage was used in 97.9%, near infrared spectroscopy in 70.8% and motor evoked potentials or somatosensory evoked potentials in 60.4%. Three of 53 centres do not utilize any form of neuromonitoring or protection during endovascular TAAA repair: 92.5% use CSF drainage; 35.8%, cerebral or paravertebral near infrared spectroscopy; and 24.5% motor evoked potentials or somatosensory evoked potentials. The utilization of CSF drainage and neuromonitoring varies depending on the extent of the TAAA repair.CONCLUSIONS: The results of this survey and of the Delphi consensus show that there is broad consensus on the importance of protecting the spinal cord to avoid spinal cord injury in patients undergoing open TAAA repair. Those measures are less frequently utilized in patients undergoing endovascular TAAA repair but should be considered, especially in patients who require extensive coverage of the thoracoabdominal aorta
    corecore