10,601 research outputs found

    Intrinsic point defects in silica for fiber optics applications

    Get PDF
    Due to its unique properties, amorphous silicon dioxide (a-SiO2 ) or silica is a key material in many technological fields, such as high-power laser systems, telecommunications, and fiber optics. In recent years, major efforts have been made in the development of highly transparent glasses, able to resist ionizing and non-ionizing radiation. However the widespread application of many silica-based technologies, particularly silica optical fibers, is still limited by the radiation-induced formation of point defects, which decrease their durability and transmission efficiency. Although this aspect has been widely investigated, the optical properties of certain defects and the correlation between their formation dynamics and the structure of the pristine glass remains an open issue. For this reason, it is of paramount importance to gain a deeper understanding of the structure–reactivity relationship in a-SiO2 for the prediction of the optical properties of a glass based on its manufacturing parameters, and the realization of more efficient devices. To this end, we here report on the state of the most important intrinsic point defects in pure silica, with a particular emphasis on their main spectroscopic features, their atomic structure, and the effects of their presence on the transmission properties of optical fibers

    Fiber Bragg Grating sensors for deformation monitoring of GEM foils in HEP detectors

    Full text link
    Fiber Bragg Grating (FBG) sensors have been so far mainly used in high energy physics (HEP) as high precision positioning and re-positioning sensors and as low cost, easy to mount, radiation hard and low space- consuming temperature and humidity devices. FBGs are also commonly used for very precise strain measurements. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide Gas Electron Multiplier (GEM) foils of the GE1/1 chambers of the Compact Muon Solenoid (CMS) experiment at Large Hadron Collider (LHC) of CERN. A network of FBG sensors has been used to determine the optimal mechanical tension applied and to characterize the mechanical stress applied to the foils. The preliminary results of the test performed on a full size GE1/1 final prototype and possible future developments will be discussed.Comment: Four pages, seven figures. Presented by Michele Caponero at IWASI 2015, Gallipoli (Italy

    Cms gem detector material study for the hl-lhc

    Get PDF
    A study on the Gaseous Electron Multiplier (GEM) foil material is performed to determine the moisture diffusion rate, moisture saturation level and the effects on its mechanical properties. The study is focused on the foil contact with ambient air and moisture to determine the value of the diffusion coefficient of water in the foil material. The presence of water inside the detector foil can determine the changes in its mechanical and electrical properties. A simulated model is developed with COMSOL Multiphysics v. 4.3 [1] by taking into account the real GEM foil (hole dimensions, shapes and material), which describes the adsorption of water. This work describes the model, its experimental verification, the water diffusion within the entire sheet geometry of the GEM foil, thus gaining concentration profiles and the time required to saturate the system and the effects on the mechanical properties

    Properties of potential eco-friendly gas replacements for particle detectors in high-energy physics

    Get PDF
    Gas detectors for elementary particles require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. This work studies properties of potential eco-friendly gas replacements by computing the physical and chemical parameters relevant for use as detector media, and suggests candidates to be considered for experimental investigation

    Properties of potential eco-friendly gas replacements for particle detectors in high-energy physics

    Full text link
    Modern gas detectors for detection of particles require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. This review studies properties of potential eco-friendly gas candidate replacements.Comment: 38 pages, 9 figures, 8 tables. To be submitted to Journal of Instrumentatio

    Candidate eco-friendly gas mixtures for MPGDs

    Get PDF
    Modern gas detectors for detection of particles require F-based gases for optimal performance.Recent regulations demand the use of environmentally unfriendly F-based gases t o be limited or banned. This review studies properties of potential eco-friendly gas candidate replacements

    A study of gas contaminants and interaction with materials in RPC closed loop systems

    Full text link
    Resistive Plate Counters (RPC) detectors at the Large Hadron Collider (LHC) experiments use gas recirculation systems to cope with large gas mixture volumes and costs. In this paper a long-term systematic study about gas purifiers, gas contaminants and detector performance is discussed. The study aims at measuring the lifetime of purifiers with unused and used cartridge material along with contaminants release in the gas system. During the data-taking the response of several RPC double-gap detectors was monitored in order to characterize the correlation between dark currents, filter status and gas contaminants

    Prolonged activity of a recombinant manganese superoxide dismutase through a formulation of polymeric multi-layer nanoassemblies targeting cancer cells

    Get PDF
    A new isoform of human manganese superoxide dismutase (SOD) has been recently isolated and obtained in a synthetic recombinant form and termed rMnSOD. As compared to other SODs, this isoform exhibits a dramatically improved cellular uptake and an intense antioxidant and antitumoral activity. Unfortunately, its use is severely hampered as this active pharmaceutical ingredient (API) in solution suffers from remarkable instability, which realizes as an interplay of unfolding and aggregation phenomena. This leads the API to be ineffective after three weeks only when stored at 4◦C. A formulation strategy was undertaken to mitigate this instability. This was based on the incorporation of the API in hyaluronic acid and its layer-by-layer deposition over a chitosan-n-acetyl cysteine- monolayer nanoemulsion (NE) and its subsequent coverage with a further external interface of a chitosan-n-acetyl cysteine. The obtained constructs were tested over a selected panel of healthy and cancerous cell lines. The undertaken formulation strategy enhanced the API’s effect in vitro already at time zero, maintaining the efficacy of this anticancer agent until up to 30 weeks when stored at 4◦C

    Differences in pigment circadian rhythmicity in green- and red-leafed tree species in the sun and shade

    Get PDF
    Light flux and quality are crucial factor for setting endogenous plant circadian rhythms. Evaluating the daily rhythmicity of leaf chlorophyll content is an effective method to monitor the plant physiological endogenous clock in response to environmental signals such as light availability/quality. Here, we used a leaf-clip sensor to monitor diurnal rhythms in the content of chlorophyll and flavonoids such as flavonols and anthocyanins in three green- (Ailanthus altissima, Tilia platyphyllos and Platanus x acerifolia) and two red-leafed (Acer platanoides cv. Crimson King and Prunus cerasifera var. pissardii) tree species, adapted to sun (L) or shade (S). Significant differences in chlorophyll content (Chl) and its variations during the day were observed among treatments in all the analyzed species. S-plants had more Chl than L-plants irrespective of leaf color, and Chl variations were more distinct during the day than in L-plants. In particular, contents were lowest in the morning (9:00) and in the middle of the day (at 12:00 and 15:00), and the highest at dusk (21:00). The less evident trends in Chl variation in L-plants were attributed to a decrease in Chl content in high light, which likely masked any increases in the shaded counterparts during the afternoon. Daily flavonol levels did not vary no notably during the day. In sun-exposed red leaves, anthocyanins partially screened mesophyll cells from incident light, and its levels were similar to the Chl dynamics in the shaded counterparts. This study provides new bases for further work on endogenous rhythms of plant pigments and improves our understanding of plant physiology in the context of day/night rhythmicity
    • …
    corecore