    Determination of iodine and molybdenum in milk by quadrupole ICP-MS

    Get PDF
    A reliable method for the determination of iodine and molybdenum in milk samples, using alkaline digestion with tetramethylammonium hydroxide and hydrogen peroxide, followed by quadrupole ICP-MS analysis, has been developed and tested using certified reference materials. The use of He + O2 (1.0 ml min-1 and 0.6 ml min-1) in the collision-reaction cell of the mass spectrometer to remove 129Xe+ - initially to enable the determination of low levels of 129I - also resulted in the quantitative conversion of Mo+ to MoO2+ which enabled the molybdenum in the milk to be determined at similar mass to the iodine with the use of Sb as a common internal standard. In order to separate and pre-concentrate iodine at sub μg L-1 concentrations, a novel method was developed using a cation-exchange column loaded with Pd2+ and Ca2+ ions to selectively retain iodide followed by elution with a small volume of ammonium thiosulfate. This method showed excellent results for aqueous iodide solutions, although the complex milk digest matrix made the method unsuitable for such samples. An investigation of the iodine species formed during oxidation and extraction of milk sample digests was carried out with a view to controlling the iodine chemistry

    Coincidence laser spectroscopy (CLS) for the detection of ions in ICP-MS (ICP-MS-CLS). A feasibility study

    No full text
    This paper reports a theoretical study of the feasibility of using laser-excited ionic fluorescence in time correlation with ion counting, termed coincidence laser spectroscopy (CLS), for improved specificity in the detection of ions in ICP-MS. The technique is here named ICP-MS-CLS. A number of factors are considered including: the preferred instrumental configuration, simulation of the performance of the optical detector and correlation step in reducing background, the spectroscopy of the selected of isotopes, 10Be+, 55Fe+, 63Ni+, 90Sr+, 99Tc+, 147Pm+, 238U+, 238Pu+ and 241Am+, which might be appropriate candidates for ICP-MS-CLS detection, the laser power required to attain saturation, the effects of ion energy and energy spread on pumping efficiency, the optical abundance sensitivity for adjacent isotopes of the same element, and the detection limits obtainable under a variety of scenarios. The ICP is established as an ideal ion source for elemental mass spectrometry, but as shown here, the ion energy spread produced is too large for optimum optical pumping because the ions are Doppler shifted to an extent that not all of them would be excited efficiently by a narrow-line laser source. This necessitates the inclusion of an ion cooler into the instrumental configuration so that ions maybe brought into resonance with the laser with 100% efficiency. The calculations show that for ions with simple spectra, such as 90Sr+ which can be repetitively pumped by the laser to produce a photon burst, ICP-MS-CLS can reduce the effect of very high backgrounds, 10 6 cps on mass and 10 10 cps at adjacent mass, to low levels and improve detection limits by 2–3 orders of magnitude compared with the normal technique. Optical abundances of 10-5 –10-9 are achievable which, combined with the mass abundance sensitivity of 10-5, yields overall abundance sensitivities of 10-10–10-14. This is of the same order as techniques such as accelerator mass spectrometry (AMS) or resonance ionisation mass spectrometry (RIMS). The technique is much less efficient for ions that undergo optical trapping and emit only one photon when pumped and/or exhibit hyperfine structure which distributes the oscillator strength over several hyperfine components. These factors significantly degrade performance and indicate a requirement for further refinement in terms of using twocolour excitation, or quenching of meta-stable levels, to enable the recycling of ions for further pumping
    corecore