17 research outputs found

    Projection-to-Projection Translation for Hybrid X-ray and Magnetic Resonance Imaging

    Get PDF
    Hybrid X-ray and magnetic resonance (MR) imaging promises large potential in interventional medical imaging applications due to the broad variety of contrast of MRI combined with fast imaging of X-ray-based modalities. To fully utilize the potential of the vast amount of existing image enhancement techniques, the corresponding information from both modalities must be present in the same domain. For image-guided interventional procedures, X-ray fluoroscopy has proven to be the modality of choice. Synthesizing one modality from another in this case is an ill-posed problem due to ambiguous signal and overlapping structures in projective geometry. To take on these challenges, we present a learning-based solution to MR to X-ray projection-to-projection translation. We propose an image generator network that focuses on high representation capacity in higher resolution layers to allow for accurate synthesis of fine details in the projection images. Additionally, a weighting scheme in the loss computation that favors high-frequency structures is proposed to focus on the important details and contours in projection imaging. The proposed extensions prove valuable in generating X-ray projection images with natural appearance. Our approach achieves a deviation from the ground truth of only 6% and structural similarity measure of 0.913 ± 0.005. In particular the high frequency weighting assists in generating projection images with sharp appearance and reduces erroneously synthesized fine details

    Peak Troponin I Levels Are Associated with Functional Outcome in Intracerebral Hemorrhage

    Get PDF
    Background: Troponin I is a widely used and reliable marker of myocardial damage and its levels are routinely measured in acute stroke care. So far, the influence of troponin I elevations during hospital stay on functional outcome in patients with atraumatic intracerebral hemorrhage (ICH) is unknown. Methods: Observational single-center study including conservatively treated ICH patients over a 9-year period. Patients were categorized according to peak troponin I level during hospital stay (≤0.040, 0.041–0.500, > 0.500 ng/mL) and compared regarding baseline and hematoma characteristics. Multivariable analyses were performed to investigate independent associations of troponin levels during hospital stay with functional outcome – assessed using the modified Rankin Scale (mRS; favorable 0–3/unfavorable 4–6) – and mortality after 3 and 12 months. To account for possible confounding propensity score (PS)-matching (1: 1; caliper 0.1) was performed accounting for imbalances in baseline characteristics to investigate the impact of troponin I values on outcome. Results: Troponin elevations (> 0.040 ng/mL) during hospital stay were observed in 308 out of 745 (41.3%) patients and associated with poorer status on admission (Glasgow Coma Scale/National Institute of Health Stroke Scale). Multivariable analysis revealed troponin I levels during hospital stay to be independently associated with unfavorable outcome after 12 months (risk ratio [95% CI]: 1.030 [1.009–1.051] per increment of 1.0 ng/mL; p = 0.005), but not with mortality. After PS-matching, patients with troponin I elevation (≥0.040 ng/mL) versus those without had a significant higher rate of ­unfavorable outcome after 3 and 12 months (mRS 4–6 at 3 months: < 0.04 ng/mL: 159/265 [60.0%] versus ≥0.04 ng/mL: 199/266 [74.8%]; p < 0.001; at 12 months: < 0.04 ng/mL: 141/248 [56.9%] versus ≥0.04 ng/mL: 179/251 [71.3%]; p = 0.001). Conclusions: Troponin I elevations during hospital stay occur frequently in ICH patients and are independently associated with functional outcome after 3 and 12 months but not with mortality

    Flow-diverting stents allow efficient treatment of unruptured, intradural dissecting aneurysms of the vertebral artery: An explanatory approach using in vivo flow analysis

    No full text
    Object Our study aimed to evaluate the efficiency of flow-diverting stents (FDS) in treating unruptured, intradural dissecting aneurysms of the vertebral artery (VADAs). Additionally, the effect of FDS on the aneurysmal flow pattern was investigated by performing in vivo flow analysis using parametric color coding (PCC). Methods We evaluated 11 patients with unruptured, intradural VADAs, treated with FDS. Pre- and postinterventional DSA-series were postprocessed by PCC, and time-density curves were calculated. The parameters aneurysmal inflow-velocity, outflow-velocity and relative time-to-peak (rTTP) were calculated. Pre- and postinterventional values were compared and correlated with the occlusion rate after six months. Results Follow-up DSA detected 10 aneurysms occluded, meaning an occlusion rate of 91%. No procedure-related morbidity and mortality was found. Flow analyses revealed a significant reduction of aneurysmal inflow- velocity and prolongation of rTTP after FDS deployment. Concerning aneurysm occlusion, the postinterventional outflow-velocity turned out to be a marginally statistically significant predictor. A definite threshold value (–0.7 density change/s) could be determined for the outflow-velocity that allows prediction of complete aneurysm occlusion with high sensitivity and specificity (100%). Conclusions Using FDS can be considered an efficient and safe therapy option in treating unruptured, intradural VADA. From in vivo flow analyses the postinterventional aneurysmal outflow-velocity turned out to be a potential predictor for later complete aneurysm occlusion. Here, it might be possible to determine a threshold value that allows prediction of aneurysm occlusion with high specificity and sensitivity. As fast, applicable and easy-to-handle tool, PCC could be used for procedural monitoring and might contribute to further treatment optimization

    Accuracy of Dose-Saving Artificial-Intelligence-Based 3D Angiography (3DA) for Grading of Intracranial Artery Stenoses: Preliminary Findings

    No full text
    Background and purpose: Based on artificial intelligence (AI), 3D angiography (3DA) is a novel postprocessing algorithm for “DSA-like” 3D imaging of cerebral vasculature. Because 3DA requires neither mask runs nor digital subtraction as the current standard 3D-DSA does, it has the potential to cut the patient dose by 50%. The object was to evaluate 3DA’s diagnostic value for visualization of intracranial artery stenoses (IAS) compared to 3D-DSA. Materials and methods: 3D-DSA datasets of IAS (nIAS = 10) were postprocessed using conventional and prototype software (Siemens Healthineers AG, Erlangen, Germany). Matching reconstructions were assessed by two experienced neuroradiologists in consensus reading, considering image quality (IQ), vessel diameters (VD1/2), vessel-geometry index (VGI = VD1/VD2), and specific qualitative/quantitative parameters of IAS (e.g., location, visual IAS grading [low-/medium-/high-grade] and intra-/poststenotic diameters [dintra-/poststenotic in mm]). Using the NASCET criteria, the percentual degree of luminal restriction was calculated. Results: In total, 20 angiographic 3D volumes (n3DA = 10; n3D-DSA = 10) were successfully reconstructed with equivalent IQ. Assessment of the vessel geometry in 3DA datasets did not differ significantly from 3D-DSA (VD1: r = 0.994, p = 0.0001; VD2:r = 0.994, p = 0.0001; VGI: r = 0.899, p = 0.0001). Qualitative analysis of IAS location (3DA/3D-DSA:nICA/C4 = 1, nICA/C7 = 1, nMCA/M1 = 4, nVA/V4 = 2, nBA = 2) and the visual IAS grading (3DA/3D-DSA:nlow-grade = 3, nmedium-grade = 5, nhigh-grade = 2) revealed identical results for 3DA and 3D-DSA, respectively. Quantitative IAS assessment showed a strong correlation regarding intra-/poststenotic diameters (rdintrastenotic = 0.995, pdintrastenotic = 0.0001; rdpoststenotic = 0.995, pdpoststenotic = 0.0001) and the percentual degree of luminal restriction (rNASCET 3DA = 0.981; pNASCET 3DA = 0.0001). Conclusions: The AI-based 3DA is a resilient algorithm for the visualization of IAS and shows comparable results to 3D-DSA. Hence, 3DA is a promising new method that allows a considerable patient-dose reduction, and its clinical implementation would be highly desirable

    Prognostic Accuracy of CTP Summary Maps in Patients with Large Vessel Occlusive Stroke and Poor Revascularization after Mechanical Thrombectomy&mdash;Comparison of Three Automated Perfusion Software Applications

    No full text
    Background: Innovative automated perfusion software solutions offer support in the management of acute stroke by providing information about the infarct core and penumbra. While the performance of different software solutions has mainly been investigated in patients with successful recanalization, the prognostic accuracy of the hypoperfusion maps in cases of futile recanalization has hardly been validated. Methods: In 39 patients with acute ischemic stroke (AIS) due to large vessel occlusion (LVO) in the anterior circulation and poor revascularization (thrombolysis in cerebral infarction (TICI) 0-2a) after mechanical thrombectomy (MT), hypoperfusion analysis was performed using three different automated perfusion software solutions (A: RAPID, B: Brainomix e-CTP, C: Syngo.via). The hypoperfusion volumes (HV) as Tmax &gt; 6 s were compared with the final infarct volumes (FIV) on follow-up CT 36&ndash;48 h after futile recanalization. Bland&ndash;Altman analysis was applied to display the levels of agreement and to evaluate systematic differences. Based on the median hypoperfusion intensity ratio (HIR, volumetric ratio of tissue with a Tmax &gt; 10 s and Tmax &gt; 6 s) patients were dichotomized into high- and low-HIR groups. Subgroup analysis with favorable (&lt;0.6) and unfavorable (&ge;0.6) HIR was performed with respect to the FIV. HIR was correlated to clinical baseline and outcome parameters using Pearson&rsquo;s correlation. Results: Overall, there was good correlation without significant differences between the HVs and the FIVs with package A (r = 0.78, p &lt; 0.001) being slightly superior to B and C. However, levels of agreement were very wide for all software applications in Bland-Altman analysis. In cases of large infarcts exceeding 150 mL the performance of the automated software solutions generally decreased. Subgroup analysis revealed the FIV to be generally underestimated in patients with HIR &ge; 0.6 (p &lt; 0.05). In the subgroup with favorable HIR, however, there was a trend towards an overestimation of the FIV. Nevertheless, packages A and B showed good correlation between the HVs and FIVs without significant differences (p &gt; 0.2), while only package C significantly overestimated the FIV (&minus;54.6 &plusmn; 56.0 mL, p = 0.001). The rate of modified Rankin Scale (mRS) 0&ndash;3 after 3 months was significantly higher in favorable vs. unfavorable HIR (42.1% vs. 13.3%, p = 0.02). Lower HIR was associated with higher Alberta Stroke Program Early CT Score (ASPECTS) at presentation and on follow-up imaging, lower risk of malignant edema, and better outcome (p &lt; 0.05). Conclusion: Overall, the performance of the automated perfusion software solutions to predict the FIV after futile recanalization is good, with decreasing accuracy in large infarcts exceeding 150 mL. However, depending on the HIR, FIV can be significantly over- and underestimated, with Syngo showing the widest range. Our results indicate that the HIR can serve as valuable parameter for outcome predictions and facilitate the decision whether or not to perform MT in delicate cases

    Pulsed Arterial Spin Labeling and Segmented Brain Volumetry in the Diagnostic Evaluation of Frontotemporal Dementia, Alzheimer’s Disease and Mild Cognitive Impairment

    No full text
    Background: Previous studies suggest that brain atrophy can not only be defined by its morphological extent, but also by the cerebral blood flow (CBF) within a certain area of the brain, including white and gray matter. The aim of this study is to investigate known atrophy patterns in different forms of dementia and to compare segmented brain volumetrics and pulsed arterial spin labeling (pASL) data to explore the correlation between brain maps with atrophy and this non-contrast-enhanced brain-perfusion method. Methods: Our study comprised 17 patients with diagnosed cognitive impairment (five Alzheimer’s disease = AD, five frontotemporal dementia = FTD, seven mild cognitive impairment = MCI) and 19 healthy control subjects (CO). All patients and controls underwent 4D-pASL brain-perfusion MR imaging and T1w MPRAGE. The data were assessed regarding relative brain volume on the basis of 286 brain regions, and absolute and relative cerebral blood flow (CBF/rCBF) were derived from pASL data in the corresponding brain regions. Mini-Mental State Examination (MMSE) was performed to assess cognitive functions. Results: FTD patients demonstrated significant brain atrophy in 43 brain regions compared to CO. Patients with MCI showed significant brain atrophy in 18 brain regions compared to CO, whereas AD patients only showed six brain regions with significant brain atrophy compared to CO. There was good correlation of brain atrophy and pASL perfusion data in five brain regions of patients with diagnosed FTD, especially in the superior temporal gyrus (r = 0.900, p = 0.037), the inferior frontal white matter (pars orbitalis; r = 0.968, p = 0.007) and the thalami (r = 0.810, p = 0.015). Patients with MCI demonstrated a correlation in one brain region (left inferior fronto-occipital fasciculus; r = 0.786, p = 0.036), whereas patients with diagnosed AD revealed no correlation. Conclusions: pASL can detect affected brain regions in cognitive impairment and corresponds with brain atrophy, especially for patients suffering from FTD and MCI. However, there was no correlation of perfusion alterations and brain atrophy in AD. pASL perfusion might thus represent a promising tool for noninvasive brain-perfusion evaluation in specific dementia subtypes as a complimentary imaging-based bio marker in addition to brain volumetry

    DSC Brain Perfusion Using Advanced Deconvolution Models in the Diagnostic Work-Up of Dementia and Mild Cognitive Impairment: A Semiquantitative Comparison with HMPAO-SPECT-Brain Perfusion

    No full text
    Background: SPECT (single-photon emission-computed tomography) is used for the detection of hypoperfusion in cognitive impairment and dementia but is not widely available and related to radiation dose exposure. We compared the performance of DSC (dynamic susceptibility contrast) perfusion using semi- and fully adaptive deconvolution models to HMPAO-SPECT (99mTc-hexamethylpropyleneamine oxime-SPECT). Material and Methods: Twenty-seven patients with dementia of different subtypes including frontotemporal dementia (FTD) and mild cognitive impairment (MCI) received a multimodal diagnostic work-up including DSC perfusion at a clinical 3T high-field scanner and HMPAO-SPECT. Nineteen healthy control individuals received DSC perfusion. For calculation of the hemodynamic parameter maps, oscillation-index standard truncated singular value decomposition (oSVD, semi-adaptive) as well as Bayesian parameter estimation (BAY, fully adaptive) were performed. Results: Patients showed decreased cortical perfusion in the left frontal lobe compared to controls (relative cerebral blood volume corrected, rBVc: 0.37 vs. 0.27, p = 0.048, adjusted for age and sex). Performance of rBVc (corrected for T1 effects) was highest compared to SPECT for detection of frontal hypoperfusion (sensitivity 83%, specificity 80% for oSVD and BAY, area under curve (AUC) = 0.833 respectively, p < 0.05) in FTD and MCI. For nonleakage-corrected rBV and for rBF (relative cerebral blood flow), sensitivity of frontal hypoperfusion was above 80% for oSVD and for BAY (rBV: sensitivity 83%, specificity 75%, AUC = 0.908 for oSVD and 0.917 for BAY, p < 0.05 respectively; rBF: sensitivity 83%, specificity 65%, AUC = 0.825, p < 0.05 for oSVD). Conclusion: Advanced deconvolution DSC can reliably detect pathological perfusion alterations in FTD and MCI. Hence, this widely accessible technique has the potential to improve the diagnosis of dementia and MCI as part of an interdisciplinary multimodal imaging work-up. Advances in knowledge: Advanced DSC perfusion has a high potential in the work-up of suspected dementia and correlates with SPECT brain perfusion results in dementia and MCI
    corecore