2,382 research outputs found
Outreach and support in South-London (OASIS) 2001-2020:Twenty years of early detection, prognosis and preventive care for young people at risk of psychosis
This study aims to describe twenty years of early detection, prognosis and preventive care in the Outreach and Support In South-London (OASIS) mental health service for individuals at Clinical High risk of psychosis (CHR-P). The study presents a comprehensive analysis of the 2001– 2020 activity of the OASIS team encompassing core domains: (i) service characteristics, (ii) detection, (iii) prognosis, (iv) treatment and (v) clinical research. The analyses employed descriptive statistics, population-level data, the epidemiological incidence of psychosis, Kaplan Meier failure functions and Greenwood 95% CIs and Electronic Health Records. OASIS is part of the South London and Maudsley (SLaM) NHS trust, the largest European mental health provider, serving a total urban population of 1,358,646 individuals (population aged 16-35: 454,525). Incidence of psychosis in OASIS's catchment area ranges from 58.3 to 71.9 cases per 100,000 person-years, and it is higher than the national average of 41.5 cases per 100,000 person-year. OASIS is a standalone, NHS-funded, multidisciplinary (team leader, consultant and junior psychiatrists, clinical psychologists, mental health professionals), transitional (for those aged 14-35 years) community mental health service with a yearly caseload of 140 CHR-P individuals. OASIS regularly delivers a comprehensive service promotion outreach to several local community organisations. Referrals to OASIS (2366) are made by numerous agencies; about one-third of the referrals eventually met CHR-P criteria. Overall, 600 CHR-P individuals (55.33% males, mean age 22.63 years, white ethnicity 46.44%) have been under the care of the OASIS service: 80.43% met attenuated psychotic symptoms, 18.06% brief and limited intermittent psychotic symptoms and 1.51% genetic risk and deterioration CHR-P criteria. All CHR-P individuals were offered cognitive behavioural therapy and psychosocial support; medications were used depending on individual needs. The cumulative risk of psychosis at ten years was 0.365 (95%CI 0.302-0.437). At six years follow-up, across two-third of individuals non-transitioning to psychosis, 79.24% still displayed some mental health problem, and only 20.75% achieved a complete clinical remission. Research conducted at OASIS encompassed clinical, prognostic, neurobiological and interventional studies and leveraged local, national and international infrastructures; over the past ten years, OASIS-related research attracted about £ 50 million of grant income, with 5,922 citations in the international databases. Future developments may include broadening OASIS to prevent other serious mental disorders beyond psychosis and fostering translational risk prediction and interventional research. With a twenty-years activity, OASIS’ cutting-edge quality of preventive care, combined with translational research innovations, consolidated the service as a leading reference model for evidence-based prevention of psychosis worldwide
Carcinoma ex pleomorphic adenoma: a case report and review of literature
Background: Carcinoma ex pleomorphic adenoma (CA-ex-PA) is extremely
unusual in minor salivary glands of oral cavity. CA-ex-PA is a
carcinomatous change as a primary or as a recurrence of pleomorphic
adenoma. Objective: Due to resemblance of clinical symptoms of Ca ex PA
and benign pleomorphic adenoma, it is mandatory for surgeons to keep
high degree of clinical alertness, considering the peculiarity of this
tumor. Case Report: 54-year-old male presented with swelling on left
side in the pre-auricular region from the middle of zygomatic arch to
mastoid process and from tragus of the ear up to angle of mandible.
Fine needle aspiration cytology revealed a mixture of benign and
malignant components. Total left parotidectomy with left radical neck
dissection followed by reconstruction with cervicodeltopectoral flap
was performed. Combination of chemotherapy and radiotherapy were given
to patient. Histologic examination and pre-operative fine needle
aspiration cytology confirmed the diagnosis of Carcinoma ex pleomorphic
adenoma (CA-ex-PA). Two-year follow-up of patient showed no recurrence
of the lesion. Conclusion: Due to the similarity in the clinical
symptoms of CA-ex-PA and benign pleomorphic adenoma, it is vital that
clinicians maintain a high degree of clinical vigilance, considering
the oddity of this malignancy
The cryomechanical design of MUSIC: a novel imaging instrument for millimeter-wave astrophysics at the Caltech Submillimeter Observatory
MUSIC (Multicolor Submillimeter kinetic Inductance Camera) is a new facility instrument for the Caltech Submillimeter Observatory (Mauna Kea, Hawaii) developed as a collaborative effect of Caltech, JPL, the University of Colorado at Boulder and UC Santa Barbara, and is due for initial commissioning in early 2011. MUSIC utilizes a new class of superconducting photon detectors known as microwave kinetic inductance detectors (MKIDs), an emergent technology that offers considerable advantages over current types of detectors for submillimeter and millimeter direct detection. MUSIC will operate a focal plane of 576 spatial pixels, where each pixel is a slot line antenna coupled to multiple detectors through on-chip, lumped-element filters, allowing simultaneously imaging in four bands at 0.86, 1.02, 1.33 and 2.00 mm. The MUSIC instrument is designed for closed-cycle operation, combining a pulse tube cooler with a two-stage Helium-3 adsorption refrigerator, providing a focal plane temperature of 0.25 K with intermediate temperature stages at approximately 50, 4 and 0.4 K for buffering heat loads and heat sinking of optical filters. Detector readout is achieved using semi-rigid coaxial cables from room temperature to the focal plane, with cryogenic HEMT amplifiers operating at 4 K. Several hundred detectors may be multiplexed in frequency space through one signal line and amplifier. This paper discusses the design of the instrument cryogenic hardware, including a number of features unique to the implementation of superconducting detectors. Predicted performance data for the instrument system will also be presented and discussed
Optimization of MKID Noise Performance Via Readout Technique for Astronomical Applications
Detectors employing superconducting microwave kinetic inductance detectors (MKIDs) can be read out by measuring changes in either the resonator frequency or dissipation. We will discuss the pros and cons of both methods, in particular, the readout method strategies being explored for the Multiwavelength Sub/millimeter Inductance Camera (MUSIC) to be commissioned at the CSO in 2010. As predicted theoretically and observed experimentally, the frequency responsivity is larger than the dissipation responsivity, by a factor of 2-4 under typical conditions. In the absence of any other noise contributions, it should be easier to overcome amplifier noise by simply using frequency readout. The resonators, however, exhibit excess frequency noise which has been ascribed to a surface distribution of two-level fluctuators sensitive to specific device geometries and fabrication techniques. Impressive dark noise performance has been achieved using modified resonator geometries employing interdigitated capacitors (IDCs). To date, our noise measurement and modeling efforts have assumed an onresonance readout, with the carrier power set well below the nonlinear regime. Several experimental indicators suggested to us that the optimal readout technique may in fact require a higher readout power, with the carrier tuned somewhat off resonance, and that a careful systematic study of the optimal readout conditions was needed. We will present the results of such a study, and discuss the optimum readout conditions as well as the performance that can be achieved relative to BLIP
Optics for MUSIC: a new (sub)millimeter camera for the Caltech Submillimeter Observatory
We will present the design and implementation, along with calculations and some measurements of the performance, of the room-temperature and cryogenic optics for MUSIC, a new (sub)millimeter camera we are developing for the Caltech Submm Observatory (CSO). The design consists of two focusing elements in addition to the CSO primary and secondary mirrors: a warm off-axis elliptical mirror and a cryogenic (4K) lens. These optics will provide a 14 arcmin field of view that is diffraction limited in all four of the MUSIC observing bands (2.00, 1.33, 1.02, and 0.86 mm). A cold (4K) Lyot stop will be used to define the primary mirror illumination, which will be maximized while keeping spillover at the sub 1% level. The MUSIC focal plane will be populated with broadband phased antenna arrays that efficiently couple to factor of (see manuscript) 3 in bandwidth, and each pixel on the focal plane will be read out via a set of four lumped element filters that define the MUSIC observing bands (i.e., each pixel on the focal plane simultaneously observes in all four bands). Finally, a series of dielectric and metal-mesh low pass filters have been implemented to reduce the optical power load on the MUSIC cryogenic stages to a quasi-negligible level while maintaining good transmission in-band
MKID multicolor array status and results from DemoCam
We present the results of the latest multicolor Microwave Kinetic Inductance Detector (MKID) focal plane arrays in the submillimeter. The new detectors on the arrays are superconducting resonators which combine a coplanar waveguide section with an interdigitated capacitor, or IDC. To avoid out-of-band pickup by the capacitor, a stepped-impedance filter is used to prevent radiation from reaching the absorptive aluminum section of the resonator. These arrays are tested in the preliminary demonstration instrument, DemoCam, a precursor to the Multicolor Submillimeter Inductance Camera, MUSIC. We present laboratory results of the responsivity to light both in the laboratory and at the Caltech Submillimeter Observatory. We assess the performance of the detectors in filtering out-of-band radiation, and find the level of excess load and its effect on detector performance. We also look at the array design characteristics, and the implications for the optimization of sensitivities expected by MUSIC
MUSIC for sub/millimeter astrophysics
MUSIC (the Multiwavelength Submillimeter kinetic Inductance Camera) is an instrument being developed for the Caltech Submillimeter Observatory by Caltech, JPL, the University of Colorado, and UCSB. MUSIC uses microwave kinetic inductance detectors (MKIDs) - superconducting micro-resonators - as photon detectors. The readout is almost entirely at room temperature and is highly multiplexed. MUSIC will have 576 spatial pixels in four bands at 850, 1100, 1300 and 2000 microns. MUSIC is scheduled for deployment at the CSO in the winter of 2010/2011. We present an overview of the camera design and readout and describe the current status of the instrument and some results from the highly successful May/June 2010 observing run at the CSO with the prototype camera, which verified the performance of the complete system (optics, antennas/filters, resonators, and readout) and produced the first simultaneous 3-color observations with any MKID camera
Integrated Transcriptomics, Metabolomics, and Lipidomics Profiling in Rat Lung, Blood, and Serum for Assessment of Laser Printer-Emitted Nanoparticle Inhalation Exposure-Induced Disease Risks
settings Open AccessArticle Integrated Transcriptomics, Metabolomics, and Lipidomics Profiling in Rat Lung, Blood, and Serum for Assessment of Laser Printer-Emitted Nanoparticle Inhalation Exposure-Induced Disease Risks by Nancy Lan Guo 1,*,Tuang Yeow Poh 2,Sandra Pirela 3,Mariana T. Farcas 4,Sanjay H. Chotirmall 2,Wai Kin Tham 5,Sunil S. Adav 5,Qing Ye 1,Yongyue Wei 6,Sipeng Shen 2,David C. Christiani 2,Kee Woei Ng 3,7,8,Treye Thomas 9,Yong Qian 4 andPhilip Demokritou 3 1 West Virginia University Cancer Institute/School of Public Health, West Virginia University, Morgantown, WV 26506, USA 2 Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore 308232, Singapore 3 Center for Nanotechnology and Nanotoxicology, Department of Environmental Health, T. H. Chan School of Public Health, Harvard University, Boston, MA 02115, USA 4 Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA 5 Singapore Phenome Centre, Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore 636921, Singapore 6 Key Lab for Modern Toxicology, Department of Epidemiology and Biostatistics and Ministry of Education (MOE), School of Public Health, Nanjing Medical University, Nanjing 210029, China 7 School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798, Singapore 8 Environmental Chemistry and Materials Centre, Nanyang Environment & Water Research Institute, Singapore 637141, Singapore 9 Office of Hazard Identification and Reduction, U.S. Consumer Product Safety Commission, Rockville, MD 20814, USA * Author to whom correspondence should be addressed. Int. J. Mol. Sci. 2019, 20(24), 6348; https://doi.org/10.3390/ijms20246348 Received: 2 December 2019 / Revised: 12 December 2019 / Accepted: 13 December 2019 / Published: 16 December 2019 (This article belongs to the Special Issue Advances in Nanostructured Materials between Pharmaceutics and Biomedicine) Download PDF Browse Figures Review Reports Cite This Paper Abstract Laser printer-emitted nanoparticles (PEPs) generated from toners during printing represent one of the most common types of life cycle released particulate matter from nano-enabled products. Toxicological assessment of PEPs is therefore important for occupational and consumer health protection. Our group recently reported exposure to PEPs induces adverse cardiovascular responses including hypertension and arrythmia via monitoring left ventricular pressure and electrocardiogram in rats. This study employed genome-wide mRNA and miRNA profiling in rat lung and blood integrated with metabolomics and lipidomics profiling in rat serum to identify biomarkers for assessing PEPs-induced disease risks. Whole-body inhalation of PEPs perturbed transcriptional activities associated with cardiovascular dysfunction, metabolic syndrome, and neural disorders at every observed time point in both rat lung and blood during the 21 days of exposure. Furthermore, the systematic analysis revealed PEPs-induced transcriptomic changes linking to other disease risks in rats, including diabetes, congenital defects, auto-recessive disorders, physical deformation, and carcinogenesis. The results were also confirmed with global metabolomics profiling in rat serum. Among the validated metabolites and lipids, linoleic acid, arachidonic acid, docosahexanoic acid, and histidine showed significant variation in PEPs-exposed rat serum. Overall, the identified PEPs-induced dysregulated genes, molecular pathways and functions, and miRNA-mediated transcriptional activities provide important insights into the disease mechanisms. The discovered important mRNAs, miRNAs, lipids and metabolites may serve as candidate biomarkers for future occupational and medical surveillance studies. To the best of our knowledge, this is the first study systematically integrating in vivo, transcriptomics, metabolomics, and lipidomics to assess PEPs inhalation exposure-induced disease risks using a rat model
Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera
We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is designed to have a 14', diffraction-limited field-of-view instrumented with 2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04, 1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies, galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own and nearby galaxies. MUSIC uses broadband superconducting phased-array slot-dipole antennas to form beams, lumpedelement on-chip bandpass filters to define spectral bands, and microwave kinetic inductance detectors to sense incoming light. The focal plane is fabricated in 8 tiles consisting of 72 spatial pixels each. It is coupled to the telescope via an ambient-temperature ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the image of the primary mirror formed by the ellipsoidal mirror. Dielectric and metal-mesh filters are used to block thermal infrared and out-ofband radiation. The instrument uses a pulse tube cooler and ^(3)He/^(3)He/^(4)He closed-cycle cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates Earth's magnetic field. Each focal plane tile is read out by a single pair of coaxes and a HEMT amplifier. The readout system consists of 16 copies of custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We focus on recent updates on the instrument design and results from the commissioning of the full camera in 2012
- …