4 research outputs found
The OnControl bone marrow biopsy technique is superior to the standard manual technique for hematologists-in-training: a prospective, randomized comparison
The purpose of this study was to compare a novel bone marrow device with the standard marrow needle in a prospective, randomized study in a teaching hospital employing hematologists-in-training. The new device, the OnControl Bone Marrow (OBM) Biopsy System, utilizes a battery-powered drill to insert the needle. Fifty-four bone marrows (27 standard and 27 OBM) were performed by 11 fellows under the observation and supervision of 3 attending hematologists and 1 research technologist. The primary endpoint of the study, the mean length of the marrow biopsy specimens, a surrogate for marrow quality, was determined by a pathologist in a blinded manner. The mean length of the marrow biopsy specimens was significantly longer (56%) for the OBM group (15.3 mm) than for the standard bone marrow (SBM) group (9.8 mm), P<0.003. An objectively determined secondary endpoint; mean procedure time, skin-to-skin; also favored the OBM group (175 s) versus the SBM group (292 s), P<0.007. Several subjective secondary endpoints also favored the OBM group. Only minor adverse events were encountered in the OBM and SBM study groups. It was concluded that bone marrow procedures (BMPs) performed by hematologists-in-training were significantly faster and superior in quality when performed with the OBM compared to the SBM. These data suggest that the OBM may be considered a new standard of care for adult hematology patients. OBM also appears to be a superior method for training hematology fellows
Powered bone marrow biopsy procedures produce larger core specimens, with less pain, in less time than with standard manual devices
Bone marrow sampling remains essential in the evaluation of hematopoietic and many non-hematopoietic disorders. One common limitation to these procedures is the discomfort experienced by patients. To address whether a Powered biopsy system could reduce discomfort while providing equivalent or better results, we performed a randomized trial in adult volunteers. Twenty-six subjects underwent bilateral biopsies with each device. Core samples were obtained in 66.7% of Manual insertions; 100% of Powered insertions (P=0.002). Initial mean biopsy core lengths were 11.1±4.5 mm for the Manual device; 17.0±6.8 mm for the Powered device (P<0.005). Pathology assessment for the Manual device showed a mean length of 6.1±5.6 mm, width of 1.0±0.7 mm, and volume of 11.0±10.8 mm3. Powered device measurements were mean length of 15.3±6.1 mm, width of 2.0±0.3 mm, and volume of 49.1±21.5 mm3 (P<0.001). The mean time to core ejection was 86 seconds for Manual device; 47 seconds for the Powered device (P<0.001). The mean second look overall pain score was 33.3 for the Manual device; 20.9 for the Powered (P=0.039). We conclude that the Powered biopsy device produces superior sized specimens, with less overall pain, in less time
Recommended from our members
Rotary powered device for bone marrow aspiration and biopsy yields excellent specimens quickly and efficiently
Recently, a new FDA-cleared battery powered bone marrow biopsy system was developed to allow operators access to the bone marrow space quickly and efficiently. A pre-clinical evaluation of the device (OnControl, Vidacare Corporation, San Antonio, TX, USA) on anesthetized pigs was conducted, in addition to a clinical evaluation in hematology clinic patients requiring a bone marrow biopsy. Twenty-six samples were collected from the swine model. No cellular artifact or thermal damage was reported in any of the samples obtained. For the clinical evaluation of the device, 16 patients were recruited. Mean time from needle contact with skin to needle removal was 38.5 +/− 13.94 seconds. No complications were reported. In this study, the manual and powered samples were equivalent in specimen quality. In the patients evaluated, the device was safe, easy to use and the mean procedural time was significantly faster than previously reported with a manual technique