Dielectric relaxation of DNA aqueous solutions
We report on a detailed characterization of complex dielectric response of
Na-DNA aqueous solutions by means of low-frequency dielectric spectroscopy (40
Hz - 110 MHz). Results reveal two broad relaxation modes of strength
20<\Delta\epsilon_LF<100 and 5<\Delta\epsilon_HF<20, centered at 0.5
kHz<\nu_LF<70 kHz and 0.1 MHz<\nu_HF<15 MHz. The characteristic length scale of
the LF process, 50<L_LF<750nm, scales with DNA concentration as
c_DNA^{-0.29\pm0.04} and is independent of the ionic strength in the low added
salt regime. Conversely, the measured length scale of the LF process does not
vary with DNA concentration but depends on the ionic strength of the added salt
as I_s^{-1} in the high added salt regime. On the other hand, the
characteristic length scale of the HF process, 3<L_HF<50 nm, varyes with DNA
concentration as c_DNA^{-0.5} for intermediate and large DNA concentrations. At
low DNA concentrations and in the low added salt limit the characteristic
length scale of the HF process scales as c_DNA^{-0.33}. We put these results in
perspective regarding the integrity of the double stranded form of DNA at low
salt conditions as well as regarding the role of different types of counterions
in different regimes of dielectric dispersion. We argue that the free DNA
counterions are primarily active in the HF relaxation, while the condensed
counterions play a role only in the LF relaxation. We also suggest theoretical
interpretations for all these length scales in the whole regime of DNA and salt
concentrations and discuss their ramifications and limitations.Comment: 15 pages, 9 figure
Microfluidic Impedance Spectroscopy as a Tool for Quantitative Biology and Biotechnology
A microfluidic device that is able to perform dielectric spectroscopy is developed. The device consists of a measurement chamber that is 250 μm thick and 750 μm radius. Around 1000 cells fit inside the chamber assuming average quantities for cell radius and volume fraction. This number is about 1000 folds lower than the capacity of conventional fixtures. A T-cell leukemia cell line Jurkat is tested using the microfluidic device. Measurements of deionized water and salt solutions are utilized to determine parasitic effects and geometric capacitance of the device. Physical models, including Maxwell-Wagner mixture and double shell models, are used to derive quantities for sub-cellular units. Clausius-Mossotti factor of Jurkat cells is extracted from the impedance spectrum. Effects of cellular heterogeneity are discussed and parameterized. Jurkat cells are also tested with a time domain reflectometry system for verification of the microfluidic device. Results indicate good agreement of values obtained with both techniques. The device can be used as a unique cell diagnostic tool to yield information on sub-cellular units. (C) 2012 American Institute of Physics
Electric-field-induced alignment of electrically neutral disk-like particles: modelling and calculation
This work reveals a torque from electric field to electrically neutral flakes that are suspended in a higher electrical conductive matrix. The torque tends to rotate the particles toward an orientation with its long axis parallel to the electric current flow. The alignment enables the anisotropic properties of tiny particles to integrate together and generate desirable macroscale anisotropic properties. The torque was obtained from thermodynamic calculation of electric current free energy at various microstructure configurations. It is significant even when the electrical potential gradient becomes as low as 100 v/m. The changes of electrical, electroplastic and thermal properties during particles alignment were discussed
Voltage-programmable liquid optical interface
Recently, there has been intense interest in photonic devices based on microfluidics, including displays and refractive tunable microlenses and optical beamsteerers, that work using the principle of electrowetting. Here, we report a novel approach to optical devices in which static wrinkles are produced at the surface of a thin film of oil as a result of dielectrophoretic forces. We have demonstrated this voltage-programmable surface wrinkling effect in periodic devices with pitch lengths of between 20 and 240 µm and with response times of less than 40 µs. By a careful choice of oils, it is possible to optimize either for high-amplitude sinusoidal wrinkles at micrometre-scale pitches or more complex non-sinusoidal profiles with higher Fourier components at longer pitches. This opens up the possibility of developing rapidly responsive voltage-programmable, polarization-insensitive transmission and reflection diffraction devices and arbitrary surface profile optical devices
Biophysical Characteristics Reveal Neural Stem Cell Differentiation Potential
Distinguishing human neural stem/progenitor cell (huNSPC) populations that will predominantly generate neurons from those that produce glia is currently hampered by a lack of sufficient cell type-specific surface markers predictive of fate potential. This limits investigation of lineage-biased progenitors and their potential use as therapeutic agents. A live-cell biophysical and label-free measure of fate potential would solve this problem by obviating the need for specific cell surface markers
Results of matching valve and root repair to aortic valve and root pathology
ObjectiveFor patients with aortic root pathology and aortic valve regurgitation, aortic valve replacement is problematic because no durable bioprosthesis exists, and mechanical valves require lifetime anticoagulation. This study sought to assess outcomes of combined aortic valve and root repair, including comparison with matched bioprosthesis aortic valve replacement.MethodsFrom November 1990 to January 2005, 366 patients underwent modified David reimplantation (n = 72), root remodeling (n = 72), or valve repair with sinotubular junction tailoring (n = 222). Active follow-up was 99% complete, with a mean of 5.6 ± 4.0 years (maximum 17 years); follow-up for vital status averaged 8.5 ± 3.6 years (maximum 19 years). Propensity-adjusted models were developed for fair comparison of outcomes.ResultsThirty-day and 5-, 10-, and 15-year survivals were 98%, 86%, 74%, and 58%, respectively, similar to that of the US matched population and better than that after bioprosthesis aortic valve replacement. Propensity-score–adjusted survival was similar across procedures (P > .3). Freedom from reoperation at 30 days and 5 and 10 years was 99%, 92%, and 89%, respectively, and was similar across procedures (P > .3) after propensity-score adjustment. Patients with tricuspid aortic valves were more likely to be free of reoperation than those with bicuspid valves at 10 years (93% vs 77%, P = .002), equivalent to bioprosthesis aortic valve replacement and superior after 12 years. Bioprostheses increasingly deteriorated after 7 years, and hazard functions for reoperation crossed at 7 years.ConclusionsValve preservation (rather than replacement) and matching root procedures have excellent early and long-term results, with increasing survival benefit at 7 years and fewer reoperations by 12 years. We recommend this procedure for experienced surgical teams
- …