53 research outputs found

    Validating a Device for Whiplash Motion Simulation in a Porcine Model

    Get PDF
    Whiplash injury is a common outcome following minor automobile collisions. One theorizedmechanism for whiplash injury is that the rapid head and neck motions induced by a collision caninjure nerve cells in the dorsal root ganglia through pressure gradients developed in the spinalcanal and surrounding tissues. This injury mechanism has previously been studied in humancadaver and porcine models. However, the whiplash motion simulation methods in the latterstudies lacked the control necessary to explore the independent effects of head rotation andretraction on the measured spinal pressures. This project aimed to address the limitations ofprevious porcine whiplash studies by developing and validating a new whiplash motion simulationdevice to enable further study of this injury mechanism. The new proposed device consists of twoservomotors which can be programmed to precisely actuate a headplate through mechanicallinkages. For the current study, an inert surrogate model was used for preliminary testing of thedevice using a whiplash motion profile from previous porcine studies. The time scale of the motionprofile was adjusted to incrementally increase severity. The positional accuracy and repeatabilityof the device was assessed through marker tracking of the headplate and logging of the motorencoder positions. Angular rates and linear accelerations of the plate were also measured. Testingdemonstrated the strengths of the proposed device in accurately and repeatably replicatingprogrammed motion profiles. Some design modifications can potentially enable simulatingwhiplash motion severities commensurate with previous porcine whiplash studies. With futuretesting using this device, our understanding of the pressure-induced whiplash injury mechanismcan be improved, which can inform effective treatments and preventative measures for whiplashinjury

    Acquisitions et services bibliographiques

    No full text
    in conformity with the requirements fo

    Prophylactic augmentation implants in the proximal femur for hip fracture prevention: An in silico investigation of simulated sideways fall impacts

    No full text
    Femoral fractures from sideways falls in the elderly are associated with significant rates of morbidity and mortality. Approaches to prevent these catastrophic injuries include pharmacological treatments, which have limited efficacy. Prophylactic femoral augmentation systems are a promising alternative that are gaining prominence by addressing the most debilitating osteoporosis-related fracture. We have developed finite element models (FEMs) of a novel experimental sideways fall simulator for cadavers. By virtue of the range of specimens and injury outcomes, these FEMs are well-suited to the evaluation of such implants. The purpose of this study was to use the FEMs to evaluate the mechanical effectiveness of three different prophylactic femoral augmentation systems. Models of the Y-Strut® (Hyprevention®, Pessac, France), Gamma Nail® (Stryker, Kalamazoo, USA), and a simple lag screw femoral fracture implant systems were placed into FEMs of five cadaveric pelvis-femur constructs embedded in a soft tissue surrogate, which were then subject to simulated sideways falls at seven impact velocities. Femur-only FEMs were also evaluated. Peak impact forces and peak acetabular forces were examined, and failure was evaluated using a strain-based criterion. We found that the femoral augmentation systems increased the peak forces prior to fracture, but were unable to prevent fracture for severe impacts. The Gamma Nail® system consistently produced the largest strength increases relative to the unaugmented femur for all five specimens in both the pendulum-drop FEMs and the femur-only simulations. In some cases, the same implant appeared to cause fractures in the acetabulum. The femur-only FEMs showed larger force increases than the pendulum-drop simulations, which suggests that the results of the femur-only simulations may not represent sideways falls as accurately as the soft tissue-embedded pendulum-drop simulations. The results from this study demonstrate the ability to simulate a high energy phenomenon and the effect of implants in an in silico environment. The results also suggest that implants could increase the force applied to the proximal femur during impact. Fracture outcomes from the tested implants can be used to inform the design of future devices, which reaffirms the value of modelling with biofidelic considerations in the implant design process. To the authors’ knowledge, this is the first paper to use more complex biofidelic FEMs to assess prophylactic femoral augmentation methods.ISSN:1751-6161ISSN:1878-018

    The efficacy of femoral augmentation for hip fracture prevention using ceramic-based cements: A preliminary experimentally-driven finite element investigation

    No full text
    Femoral fractures due to sideways falls continue to be a major cause of concern for the elderly. Existing approaches for the prevention of these injuries have limited efficacy. Prophylactic femoral augmentation systems, particularly those involving the injection of ceramic-based bone cements, are gaining more attention as a potential alternative preventative approach. We evaluated the mechanical effectiveness of three variations of a bone cement injection pattern (basic ellipsoid, hollow ellipsoid, small ellipsoid) utilizing finite element simulations of sideways fall impacts. The basic augmentation pattern was tested with both high- and low-strength ceramic-based cements. The cement patterns were added to the finite element models (FEMs) of five cadaveric femurs, which were then subject to simulated sideways falls at seven impact velocities ranging from 1.0 m/s to 4.0 m/s. Peak impact forces and peak acetabular forces were examined, and failure was evaluated using a strain-based criterion. We found that the basic HA ellipsoid provided the highest increases in both the force at the acetabulum of the impacted femur (“acetabular force”, 55.0% ± 22.0%) and at the force plate (“impact force”, 37.4% ± 15.8%). Changing the cement to a weaker material, brushite, resulted in reduced strengthening of the femur (45.2% ± 19.4% acetabular and 30.4% ± 13.0% impact). Using a hollow version of the ellipsoid appeared to have no effect on the fracture outcome and only a minor effect on the other metrics (54.1% ± 22.3% acetabular force increase and 35.3% ± 16.0% impact force increase). However, when the outer two layers of the ellipsoid were removed (small ellipsoid), the force increases that were achieved were only 9.8% ± 5.5% acetabular force and 8.2% ± 4.1% impact force. These results demonstrate the importance of supporting the femoral neck cortex to prevent femoral fractures in a sideways fall, and provide plausible options for prophylactic femoral augmentation. As this is a preliminary study, the surgical technique, the possible effects of trabecular bone damage during the augmentation process, and the effect on the blood supply to the femoral head must be assessed further.ISSN:2296-418

    On the internal reaction forces, energy absorption, and fracture in the hip during simulated sideways fall impact.

    Get PDF
    The majority of hip fractures have been reported to occur as a result of a fall with impact to the greater trochanter of the femur. Recently, we developed a novel cadaveric pendulum-based hip impact model and tested two cadaveric femur-pelvis constructs, embedded in a soft tissue surrogate. The outcome was a femoral neck fracture in a male specimen while a female specimen had no fracture. The aim of the present study was, first, to develop a methodology for constructing and assessing the accuracy of explicit Finite Element Models (FEMs) for simulation of sideways falls to the hip based on the experimental model. Second, to use the FEMs for quantifying the internal reaction forces and energy absorption in the hip during impact. Third, to assess the potential of the FEMs in terms of separating a femoral fracture endpoint from a non-fracture endpoint. Using a non-linear, strain rate dependent, and heterogeneous material mapping strategy for bone tissue in these models, we found the FEM-derived results to closely match the experimental test results in terms of impact forces and displacements of pelvic video markers up to the time of peak impact force with errors below 10%. We found the internal reaction forces in the femoral neck on the impact side to be approximately 35% lower than the impact force measured between soft tissue and ground for both specimens. In addition, we found the soft tissue to be the component that absorbed the largest part of the energy of the tissue types in the hip region. Finally, we found surface strain patterns derived from FEM results to match the fracture location and extent based on post testing x-rays of the specimens. This is the first study with quantitative data on the energy absorption in the pelvic region during a sideways fall
    corecore