Plasduino: an inexpensive, general purpose data acquisition framework for educational experiments
Based on the Arduino development platform, Plasduino is an open-source data
acquisition framework specifically designed for educational physics
experiments. The source code, schematics and documentation are in the public
domain under a GPL license and the system, streamlined for low cost and ease of
use, can be replicated on the scale of a typical didactic lab with minimal
effort. We describe the basic architecture of the system and illustrate its
potential with some real-life examples.Comment: 11 pages, 10 figures, presented at the XCIX conference of the
Societ\`a Italiana di Fisic
XIMPOL: A new X-ray polarimetry observation-simulation and analysis framework
We present a new simulation framework, based on the python programming language and specifically developed for X-ray polarimetric applications, called XIMPOL. Starting from an arbitrary source model (including morphological, temporal, spectral and polarimetric informations), XIMPOL uses the response functions of the detector under study to produce fast and realistic observationsimulations. A Chandra-to-XIMPOL converter is also available within the framework, designed to convert a real Chandra observation into a XIMPOL simulation. The generated output files can be directly fed into the standard visualization and analysis tools, including XSPEC, which makeXIMPOL a useful tool not only for simulating observations of astronomical sources, but also to develop and test end-to-end analysis chains
ixpeobssim: a Simulation and Analysis Framework for the Imaging X-ray Polarimetry Explorer
ixpeobssim is a simulation and analysis framework, based on the Python
programming language and the associated scientific ecosystem, specifically
developed for the Imaging X-ray Polarimetry Explorer (IXPE). Given a source
model and the response functions of the telescopes, it is designed to produce
realistic simulated observations, in the form of event lists in FITS format,
containing a strict super-set of the information provided by standard IXPE
level-2 files. The core ixpeobssim simulation capabilities are complemented by
a full suite of post-processing applications, allowing for the implementation
of complex, polarization-aware analysis pipelines, and facilitating the
inter-operation with the standard visualization and analysis tools
traditionally in use by the X-ray community. We emphasize that, although a
significant part of the framework is specific to IXPE, the modular nature of
the underlying implementation makes it potentially straightforward to adapt it
to different missions with polarization capabilities.Comment: 12 pages, 6 figures. Accepted for publication on SoftwareX; source
code available at https://github.com/lucabaldini/ixpeobssi
Low energy polarization sensitivity of the Gas Pixel Detector
An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been
proposed to be included in many upcoming space missions to fill the gap of
about 30 years from the first (and to date only) positive measurement of
polarized X-ray emission from an astrophysical source. The estimated
sensitivity of the current prototype peaks at an energy of about 3 keV, but the
lack of readily available polarized sources in this energy range has prevented
the measurement of detector polarimetric performances.
In this paper we present the measurement of the Gas Pixel Detector
polarimetric sensitivity at energies of a few keV and the new, light, compact
and transportable polarized source that was devised and built to this aim.
Polarized photons are produced, from unpolarized radiation generated with an
X-ray tube, by means of Bragg diffraction at nearly 45 degrees.
The employment of mosaic graphite and flat aluminum crystals allow the
production of nearly completely polarized photons at 2.6, 3.7 and 5.2 keV from
the diffraction of unpolarized continuum or line emission. The measured
modulation factor of the Gas Pixel Detector at these energies is in good
agreement with the estimates derived from a Monte Carlo software, which was up
to now employed for driving the development of the instrument and for
estimating its low energy sensitivity. In this paper we present the excellent
polarimetric performance of the Gas Pixel Detector at energies where the peak
sensitivity is expected. These measurements not only support our previous
claims of high sensitivity but confirm the feasibility of astrophysical X-ray
photoelectric polarimetry.Comment: 15 pages, 12 figures. Accepted for publication in NIM
Imaging with the invisible light
We describe a UV photo-detector with single photon(electron) counting and
imaging capability. It is based on a CsI photocathode, a GEM charge multiplier
and a self triggering CMOS analog pixel chip with 105k pixels at 50 micron
pitch. The single photoelectron produced by the absorption of a UV photon is
drifted to and multiplied inside a single GEM hole. The coordinates of the GEM
avalanche are reconstructed with high accuracy (4 micron rms) by the pixel
chip. As a result the map of the GEM holes, arranged on a triangular pattern at
50micron pitch, is finely imaged.Comment: 6 pages, 14 figures, presented at the 11th Vienna Conference on
Instrumentation VIC 2007, submitted to Nuclear Instruments and Methods
- …