8 research outputs found

    Outcomes of COVID-19 patients treated with continuous positive airway pressure outside ICU

    Get PDF
    Aim We aim at characterizing a large population of Coronavirus 19 (COVID-19) patients with moderate-to-severe hypoxemic acute respiratory failure (ARF) receiving CPAP outside intensive care unit (ICU), and ascertaining whether the duration of CPAP application increased the risk of mortality for patients requiring intubation. Methods In this retrospective, multicentre cohort study, we included COVID-19 adult patients, treated with CPAP outside ICU for hypoxemic ARF from March 1 st to April 15th, 2020. We collected demographic and clinical data, including CPAP therapeutic goal, hospital length of stay (LOS), and 60- day in-hospital mortality. Results The study includes 537 patients with a median age of 69 (IQR, 60-76) years. Males were 391 (73%). According to predefined CPAP therapeutic goal, 397 (74%) patients were included in full treatment subgroup, and 140 (26%) in the do-not intubate (DNI) subgroup. Median CPAP duration was 4 (IQR, 1-8) days, while hospital LOS 16 (IQR, 9-27) days. Sixty-day in-hospital mortality was overall 34% (95%CI, 0.304-0.384), and 21% (95%CI, 0.169-0.249) and 73% (95%CI, 0.648-0.787) for full treatment and DNI subgroups, respectively. In the full treatment subgroup, in-hospital mortality was 42% (95%CI, 0.345-0.488) for 180 (45%) CPAP failures requiring intubation, while 2% (95%CI, 0.008- 0.035) for the remaining 217 (55%) patients who succeeded. Delaying intubation was associated with increased mortality [HR, 1.093 (95%CI, 1.010-1.184)]. Conclusions We described a large population of COVID-19 patients treated with CPAP outside ICU. Intubation delay represents a risk factor for mortality. Further investigation is needed for early identification of CPAP failures

    Esophageal Pressure Versus Gas Exchange to Set PEEP During Intraoperative Ventilation

    No full text
    BACKGROUND: Pneumoperitoneum and Trendelenburg position affect respiratory system mechanics and oxygenation during elective pelvic robotic surgery. The primary aim of this randomized pilot study was to compare the effects of a conventional low tidal volume ventilation with PEEP guided by gas exchange (VGas-guided) versus low tidal volume ventilation tailoring PEEP according to esophageal pressure (VPes-guided) on oxygenation and respiratory mechanics during elective pelvic robotic surgery. METHODS: This study was conducted in a single-center tertiary hospital between September 2017 and January 2019. Forty-nine adult patients scheduled for elective pelvic robotic surgery were screened; 28 subjects completed the full analysis. Exclusion criteria were American Society of Anesthesiologists physical status >= 3, contraindications to nasogastric catheter placement, and pregnancy. After dedicated naso/orogastric catheter insertion, subjects were randomly assigned to VGas-guided (F-IO2 and PEEP set to achieve S-pO2 > 94%) or VPes-guided (PEEP tailored to equalize end-expiratory transpulmonary pressure). Oxygenation (P-aO2/F-IO2) was evaluated (1) at randomization, after pneumoperitoneum and Trendelenburg application; (2) at 60 min; (3) at 120 min following randomization; and (4) at end of surgery. Respiratory mechanics were assessed during the duration of the study. RESULTS: Compared to VGas-guided, oxygenation was higher with VPes-guided at 60 min (388 +/- 90 vs 308 +/- 95 mm Hg, P = .02), at 120 min after randomization (400 +/- 90 vs 308 +/- 81 mm Hg, P = .008), and at the end of surgery (402 +/- 95 vs 312 +/- 95 mm Hg, P = .009). Respiratory system elastance was lower with VPes-guided compared to VGas-guided at 20 min (24.2 +/- 7.3 vs 33.4 +/- 10.7 cm H2O/L, P = .001) and 60 min (24.1 +/- 5.4 vs 31.9 +/- 8.5 cm H2O/L, P 5.006) from randomization. CONCLUSIONS: Oxygenation and respiratory system mechanics were improved when applying a ventilatory strategy tailoring PEEP to equalize expiratory transpulmonary pressure in subjects undergoing pelvic robotic surgery compared to a VGas-guided approach

    Esophageal Pressure Versus Gas Exchange to Set PEEP During Intraoperative Ventilation

    No full text
    Pneumoperitoneum and Trendelenburg position affect respiratory system mechanics and oxygenation during elective pelvic robotic surgery. The primary aim of this randomized pilot study was to compare the effects of a conventional low tidal volume ventilation with PEEP guided by gas exchange (VGas-guided) versus low tidal volume ventilation tailoring PEEP according to esophageal pressure (VPes-guided) on oxygenation and respiratory mechanics during elective pelvic robotic surgery

    Mechanical Ventilation Guided by Uncalibrated Esophageal Pressure May Be Potentially Harmful

    No full text
    Esophageal balloon calibration was proposed in acute respiratory failure patients to improve esophageal pressure assessment. In a clinical setting characterized by a high variability of abdominal load and intrathoracic pressure (i.e., pelvic robotic surgery), the authors hypothesized that esophageal balloon calibration could improve esophageal pressure measurements. Accordingly, the authors assessed the impact of esophageal balloon calibration compared to conventional uncalibrated approach during pelvic robotic surgery

    Diaphragmatic Kinetics Assessment by Tissue Doppler Imaging and Extubation Outcome: An Observational Study

    No full text
    BACKGROUND: The assessment of diaphragmatic kinetics through tissue Doppler imaging (dTDI) was recently proposed as a means to describe diaphragmatic activity in both healthy individuals and intubated patients undergoing weaning from mechanical ventilation. Our primary aim was to investigate whether the diaphragmatic excursion velocity measured with dTDI at the end of a spontaneous breathing trial (SBT) was different in subjects successfully extubated versus those who passed the trial but exhibited extubation failure within 48 h after extubation.METHODS: We enrolled 100 adult subjects, all of whom had successfully passed a 30-min SBT conducted in CPAP of 5 cm H2O. In cases of extubation failure within 48 h after liberation from invasive mechanical ventilation, subjects were re-intubated or supported through noninvasive ventilation. dTDI was performed at the end of the SBT to assess excursion, velocity, and acceleration.RESULTS: Extubation was successful in 79 subjects, whereas it failed in 21 subjects. The median (interquartile range [IQR]) inspiratory peak excursion velocity (3.1 [IQR 2.0-4.3] vs 1.8 [1.3-2.6] cm/s, P < .001), mean velocity (1.6 [IQR 1.2-2.4] vs 1.1 [IQR 0.8-1.4] cm/s, P < .001), and acceleration (8.8 [IQR 5.0-17.8] vs 4.2 [IQR 2.4-8.0] cm/s2, P = .002) were all significantly higher in subjects who failed extubation compared with those who were successfully extubated. Similarly, the median expiratory peak relaxation velocity (2.6 [IQR 1.9-4.5] vs 1.8 [IQR 1.2-2.5] cm/s, P < .001), mean velocity (1.1 [IQR 0.7-1.7] vs 0.9 [IQR 0.6-1.0] cm/s, P = .002), and acceleration (11.2 [IQR 9.1-19.0] vs 7.1 [IQR 4.6-12.0] cm/s2, P = .004) were also higher in the subjects who failed extubation.CONCLUSIONS: In our setting, at the end of SBT, subjects who developed extubation failure within 48 h after extubation experienced a greater diaphragmatic activation compared with subjects who were successfully extubated. (ClinicalTrials.gov registration NCT03962322.)

    Early extubation with immediate non-invasive ventilation versus standard weaning in intubated patients for coronavirus disease 2019: a retrospective multicenter study

    No full text
    In patients intubated for hypoxemic acute respiratory failure (ARF) related to novel coronavirus disease (COVID-19), we retrospectively compared two weaning strategies, early extubation with immediate non-invasive ventilation (NIV) versus standard weaning encompassing spontaneous breathing trial (SBT), with respect to IMV duration (primary endpoint), extubation failures and reintubations, rate of tracheostomy, intensive care unit (ICU) length of stay and mortality (additional endpoints). All COVID-19 adult patients, intubated for hypoxemic ARF and subsequently extubated, were enrolled. Patients were included in two groups, early extubation followed by immediate NIV application, and conventionally weaning after passing SBT. 121 patients were enrolled and analyzed, 66 early extubated and 55 conventionally weaned after passing an SBT. IMV duration was 9 [6-11] days in early extubated patients versus 11 [6-15] days in standard weaning group (p\u2009=\u20090.034). Extubation failures [12 (18.2%) vs. 25 (45.5%), p\u2009=\u20090.002] and reintubations [12 (18.2%) vs. 22 (40.0%) p\u2009=\u20090.009] were fewer in early extubation compared to the standard weaning groups, respectively. Rate of tracheostomy, ICU mortality, and ICU length of stay were no different between groups. Compared to standard weaning, early extubation followed by immediate NIV shortened IMV duration and reduced the rate of extubation failure and reintubation
    corecore