4 research outputs found

    Management of <em>E. coli</em> Sepsis

    Get PDF
    E. coli is the most common cause of urinary tract infections (UTIs) in humans and is a leading cause of enteric infections and systemic infections. The systemic infections include bacteremia, nosocomial pneumonia, cholecystitis, cholangitis, peritonitis, cellulitis, osteomyelitis, and infectious arthritis. E. coli is also the leading cause of neonatal meningitis

    Aortic Aneurysm: Clinical Findings, Diagnostic and Treatment

    Get PDF
    The aorta is the largest artery in the body and can have aneurysms, which are focal expansions of the vessel wall that can occur anywhere throughout the artery. These can be classified as thoracic, abdominal or thoracoabdominal aneurysms and can be caused by several etiologies, including degenerative, infectious, and genetic causes. Most aortic aneurysms are asymptomatic and are detected incidentally while looking for other primary diseases with a physical exam finding of a pulsatile mass, or with imaging such as ultrasound, computed tomography, x-rays, or magnetic resonance imaging. When symptoms are present, they are often nonspecific and occur due to inflammation, rapid expansion, compression/erosion of the aneurysm into surrounding structures, or rupture. Uncontrolled aortic aneurysms can lead to fatal outcomes, thus making proper management essential. Management can range from medical treatment to surgical repair based on location, size, rate of expansion, and presence of symptoms

    Sterilization and sanitizing of 3D-printed personal protective equipment using polypropylene and a Single Wall design

    No full text
    Abstract Background The emergence of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic during the fall of 2019 and into the spring of 2020 has led to an increased demand of disposable N95 respirators and other types of personal protective equipment (PPE) as a way to prevent virus spread and help ensure the safety of healthcare workers. The sudden demand led to rapid modification, development, and dissemination of 3D printed PPE. The goal of this study was to determine the inherent sterility and re-sterilizing ability of 3D printed PPE in order to provide sterile equipment to the healthcare field and the general public. Methods Samples of polylactic acid (PLA), thermoplastic polyurethane (TPU) (infill-based designs) and polypropylene (single-wall hollow design) were 3D printed. Samples were inoculated with E. coli for 24 h and then sanitized using various chemical solutions or heat-based methods. The samples were then incubated for 24- or 72-h in sterile LB medium at 37°C, and bacterial growth was measured by optical density at 600nm. Statistical analysis was conducted using GraphPad Prism v8.2.1. Results Significant bacterial growth was observed in all PLA and TPU based samples following re-sterilization, regardless of the methods used when compared to controls (p  0.05) observed regardless of sanitization method used. Conclusion The cost effectiveness, ease of sanitization, and reusability of 3D printed PPE, using our novel single-walled polypropylene design can help meet increased demands of PPE for healthcare workers and the general public that are needed to help decrease the viral transmission of the coronavirus disease of 2019 (COVID-19) pandemic. 3D printing also has the potential to lead to the creation and production of other sterile material items for the healthcare industry in the future. The ability to re-sterilize 3D printed PPE, as our design shows, would also contribute less to the increase in biomedical waste (BMW) being experienced by COVID-19

    Optical Density Optimization of Malaria Pan Rapid Diagnostic Test Strips for Improved Test Zone Band Intensity

    No full text
    For the last few decades, the immunochromatographic assay has been used for the rapid detection of biological markers in infectious diseases in humans and animals The assay, also known as lateral flow assay, is utilized for the detection of antigen or antibody in human infectious diseases. There are a series of steps involved in the development of these immuno-chromatographic test kits, from gold nano colloids preparation to nitrocellulose membrane coating (NCM). These tests are mostly used for qualitative assays by a visual interpretation of results. For the interpretation of the results, the color intensity of the test zone is therefore very significant. Herein, the study was performed on a malaria antigen test kit. Several studies have reported the use of gold nanoparticles (AuNPs) with varying diameters and its binding with various concentrations of protein in order to optimize tests. However, none of these studies have reported how to fix (improve) test zone band intensity (color), if different sized AuNPs were synthesized during a reaction and when conjugated equally with same amount of protein. Herein, different AuNPs with average diameter ranging from 10 nm to 50 nm were prepared and conjugated equally with protein concentration of 150 &micro;g/mL with KD = 1.0 &times; 10&minus;3. Afterwards, the developed kits&rsquo; test zone band intensity for all different sizes AuNPs was fixed to the same band level (high) by utilization of an ultraviolet-visible spectrophotometer. The study found that the same optical density (OD) has the same test zone band intensity irrespective of AuNP size. This study also illustrates the use of absorption maxima (&lambda; max) techniques to characterize AuNPs and to prevent wastage of protein while developing immunochromatographic test kits
    corecore