84 research outputs found

    Mapping the optical absorption of a substrate-transferred crystalline AlGaAs coating at 1.5 µm

    Get PDF
    The sensitivity of 2nd and 3rd generations of interferometric gravitational wave detectors will be limited by thermal noise of the test-mass mirrors and highly reflective coatings. Recently developed crystalline coatings show a promising thermal noise reduction compared to presently used amorphous coatings. However, stringent requirements apply to the optical properties of the coatings as well. We have mapped the optical absorption of a crystalline AlGaAs coating which is optimized for high reflectivity for a wavelength of 1064nm. The absorption was measured at 1550nm where the coating stack transmits approximately 70% of the laser light. The measured absorption was lower than (30.2 +/- 11.1)ppm which is equivalent to (3.6 +/- 1.3)ppm for a coating stack that is highly reflective at 1530nm. While this is a very promising low absorption result for alternative low--loss coating materials, further work will be necessary to reach the requirements of <1ppm for future gravitational wave detectors. Jessica Steinlechner, Iain W Martin, Angus Bell, Garrett Cole, Jim Hough, Steven Penn, Sheila Rowan, Sebastian Steinlechne

    Bulk Crystal Growth of Piezoelectric PMN-PT Crystals Using Gradient Freeze Technique for Improved SHM Sensors

    Get PDF
    There has been a growing interest in recent years in lead based perovskite ferroelectric and relaxor ferroelectric solid solutions because of their excellent dielectric, piezoelectric and electrostrictive properties that make them very attractive for various sensing, actuating and structural health monitoring (SHM) applications. We are interested in the development of highly sensitive and efficient PMN-PT sensors based on large single crystals for the structural health monitoring of composite materials that may be used in future spacecrafts. Highly sensitive sensors are needed for detection of defects in these materials because they often tend to fail by distributed and interacting damage modes and much of the damage occurs beneath the top surface of the laminate and not detectable by visual inspection. Research is being carried out for various combinations of solid solutions for PMN-PT piezoelectric materials and bigger size crystals are being sought for improved sensor applications. Single crystals of this material are of interest for sensor applications because of their high piezoelectric coefficient (d33 greater than 1700 pC/N) and electromechanical coefficients (k33 greater than 0.90). For comparison, the commonly used piezoelectric ceramic lead zirconate titanate (PZT) has a d33 of about 600 pC/N and electromechanical coefficients k33 of about 0.75. At the present time, these piezoelectric relaxor crystals are grown by high temperature flux growth method and the size of these crystals are rather small (~3x4x5 mm(exp 3). In the present paper, we have attempted to grow bulk single crystals of PMN-PT in a 2 inch diameter platinum crucible and successfully grown a large size crystal of 67%PMN-33%PT using the vertical gradient freeze technique with no flux. Piezoelectric properties of the grown crystals are investigated. PMN-PT plates show excellent piezoelectric properties. Samples were poled under an applied electric field of 5 kV/cm. Dielectric properties at a frequency of 1 kHz are examined. The grown PMN-PT crystals show typical relaxor dielectric properties. Additionally, the thermal properties of the sample are tested. The results are in good agreement with those found in the literature and some are reported for the first time

    Explorando la Cultura Mayangna de Nicaragua a través del FODA

    Get PDF
    Una exploración en una de las naciones indígenas de América Central utilizando la técnica FODA que usualmente se emplea en el área de negocios. Los autores han visitado a la población Mayangna y han leído sobre ellos como parte del proceso de empatía. Lo están haciendo con la esperanza de eventualmente crear un programa culturalmente sensible para ayudar al liderazgo Mayangna a lograr los objetivos que establecieron para su nación y para sus comunidades. Esta es una región especial de un país especial y alejada de los destinos turísticos típicos. A través del trabajo con la Universidad de las Regiones Autónomas de la Costa Caribe Nicaragüense (URACCAN), se obtuvieron presentaciones y acceso a la Nación Sumu - Mayangna. El documento es una exploración de lo que se ha aprendido hasta la fecha de octubre 201

    Pendulum Mode Thermal Noise in Advanced Interferometers: A comparison of Fused Silica Fibers and Ribbons in the Presence of Surface Loss

    Get PDF
    The use of fused-silica ribbons as suspensions in gravitational wave interferometers can result in significant improvements in pendulum mode thermal noise. Surface loss sets a lower bound to the level of noise achievable, at what level depends on the dissipation depth and other physical parameters. For LIGO II, the high breaking strength of pristine fused silica filaments, the correct choice of ribbon aspect ratio (to minimize thermoelastic damping), and low dissipation depth combined with the other achievable parameters can reduce the pendulum mode thermal noise in a ribbon suspension well below the radiation pressure noise. Despite producing higher levels of pendulum mode thermal noise, cylindrical fiber suspensions provide an acceptable alternative for LIGO II, should unforeseen problems with ribbon suspensions arise.Comment: Submitted to Physics Letters A (Dec. 14, 1999). Resubmitted to Physics Letters A (Apr. 3, 2000) after internal (LSC) review process. PACS - 04.80.Nn, 95.55.Ym, 05.40.C

    Titania-doped tantala/silica coatings for gravitational-wave detection

    Get PDF
    Reducing thermal noise from optical coatings is crucial to reaching the required sensitivity in next generation interferometric gravitational-wave detectors. Here we show that adding TiO2 to Ta2O5 in Ta2O5/SiO2 coatings reduces the internal friction and in addition present data confirming it reduces thermal noise. We also show that TiO2-doped Ta2O5/SiO2 coatings are close to satisfying the optical absorption requirements of second generation gravitational-wave detectors

    Mirror coating solution for the cryogenic Einstein telescope

    Get PDF
    Planned, cryogenic gravitational-wave detectors will require improved coatings with a strain thermal noise reduced by a factor of 25 compared to Advanced LIGO. In this article, we present investigations of HfO2 doped with SiO2 as a new coating material for future detectors. Our measurements show an extinction coefficient of k=6×10−6 and a mechanical loss of ϕ=3.8×10−4 at 10,K, which is a factor of 2 below that of SiO2, the currently used low refractive-index coating material. These properties make HfO2 doped with SiO2 ideally suited as a low-index partner material for use with a-Si in the lower part of a multimaterial coating. Based on these results we present a multimaterial coating design which, for the first time, can simultaneously meet the strict requirements on optical absorption and thermal noise of the cryogenic Einstein Telescope

    Thermal noise in interferometric gravitational wave detectors due to dielectric optical coatings

    Full text link
    We report on thermal noise from the internal friction of dielectric coatings made from alternating layers of Ta2O5 and SiO2 deposited on fused silica substrates. We present calculations of the thermal noise in gravitational wave interferometers due to optical coatings, when the material properties of the coating are different from those of the substrate and the mechanical loss angle in the coating is anisotropic. The loss angle in the coatings for strains parallel to the substrate surface was determined from ringdown experiments. We measured the mechanical quality factor of three fused silica samples with coatings deposited on them. The loss angle of the coating material for strains parallel to the coated surface was found to be (4.2 +- 0.3)*10^(-4) for coatings deposited on commercially polished slides and (1.0 +- 0.3)*10^{-4} for a coating deposited on a superpolished disk. Using these numbers, we estimate the effect of coatings on thermal noise in the initial LIGO and advanced LIGO interferometers. We also find that the corresponding prediction for thermal noise in the 40 m LIGO prototype at Caltech is consistent with the noise data. These results are complemented by results for a different type of coating, presented in a companion paper.Comment: Submitted to LSC (internal) review Sept. 20, 2001. To be submitted to Phys. Lett.

    Optical coatings for gravitational wave detection

    Get PDF
    Gravitational waves are a prediction of Einstein's General Theory of Relativity. Astrophysical events like supernova and binary neutron star inspirals are predicted to create potentially detectable waves. The Laser Interferometer Gravitational-wave Observatory (LIGO) is an experiment to detect these waves using Michelson interferometers with 4 km long arms. The effect of gravitational waves, even on an interferometer with such a long baseline, is extremely, with mirror displacements around 10^(-18)m. Reducing noise is thus a primary design criterion. For the next generation interferometers now being designed, thermal noise from the optical coatings of the interferometer mirrors could prove a problematic limiting noise source. Reducing the mechanical loss of these coatings to improve thermal noise, while preserving the sub-ppm optical absorption, low scatter, and high reflectivity needed in the interferometer is an important area of research

    The Search for Gravitational Waves

    Full text link
    Experiments aimed at searching for gravitational waves from astrophysical sources have been under development for the last 40 years, but only now are sensitivities reaching the level where there is a real possibility of detections being made within the next five years. In this article a history of detector development will be followed by a description of current detectors such as LIGO, VIRGO, GEO 600, TAMA 300, Nautilus and Auriga. Preliminary results from these detectors will be discussed and related to predicted detection rates for some types of sources. Experimental challenges for detector design are introduced and discussed in the context of detector developments for the future.Comment: 21 pages, 7 figures, accepted J. Phys. B: At. Mol. Opt. Phy
    • …
    corecore