    Theoretical Analysis of Deformation and Internal Forces of Used Piles Due to New Static-Pressure Pile Penetration

    No full text
    Evaluation of the impact of new static-pressure pile penetration on used piles is vitally important for the reutilization of the used piles. The cavity expansion theory in semi-infinite soil is adopted to obtain the displacement field of the surrounding soil caused by new pile penetration, and then the displacement is applied to the used pile based on a two-stage method to analyze the deformation and internal force of the used pile. The effects of constraint conditions of the used pile, the pile rigidity and the soil modulus on the response of the used pile are considered. Meanwhile, numerical analysis is adopted to verify the effectiveness of the theoretical method. The influence of the distance between the new and used piles and the radius of the new pile is analyzed, and the measures to reduce the influence of new pile penetration on existing piles are proposed. The results show that the form of pile end only affects the deformation near the pile end. With the increase in pile diameter, the existing pile deformation gradually increases. As the distance between the existing pile and new pile increases, the existing pile deformation decreases significantly

    A Semi-Analytical Solution for Shock Wave Pressure and Radius of Soil Plastic Zone Induced by Lightning Strikes

    No full text
    A semi-analytical solution for forecasting the soil behavior induced by lightning strikes is of great engineering significance to calculate the radius of the soil plastic zone. In this paper, a simplified two-stage method is employed to solve the shock wave pressure and the radius of the soil plastic zone. The solution is verified against experimental data. Using the present model, the major factors dominating the shock wave pressure and the radius of the soil plastic zone are investigated. The results show that (1) the radius of the soil plastic zone (rp) induced by lightning decreases monotonically with cohesion (c) and internal friction angle (φ), while c has a better effect on soil properties than φ does; (2) increasing the initial radius of the plasma channel (ri0) can reduce the pressure (P) and increasing ri0 has a nonnegligible effect on rp; with ri0 increasing by 100%, the radius of the soil plastic zone increases by 47.9–59.7%; (3) the plasma channel length (L) has a significant influence on P and rp, especially when L is at a relatively low level; (4) the rp induced by lightning decreases exponentially with attenuation coefficient (a); (5) the wavefront time is a major factor while the half-value time is a minor factor for the shock wave pressure induced by plasma explosives

    The Utilization of a Coupled Electro-Thermal-Mechanical Model of High-Voltage Electric Pulse on Rock Fracture

    No full text
    Our research proposes a unique coupled electro-thermal-mechanical model that takes electric breakdown and heterogeneity into account to show the mechanism of rock fracturing under high-voltage electropulses. Using finite element numerical software, the process of high voltage electrical pulse injection into the rock interior for breakdown is described, and the formation law of plasma channels during the electrical breakdown process is comprehensively analyzed in conjunction with the conductor particles present within the rock. On the basis of electrical, thermal, and mechanical theories, a coupled multi-physical field numerical model of rock failure under the action of high-voltage electrical pulses is developed, and a random distribution model is utilized to simulate the potential occurrence of conductor particles in the rock. Innovative numerical model indicates plasma channel creation in the rock-crushing process. Prior to the formation of the plasma channel, the temperature and stress are approximately 103 k and 10−2 MPa, respectively. Once the plasma channel is formed, the temperature and stress increase abruptly in a short time, with the temperature reaching 104 k and the stress reaching 103 MPa or higher. In addition, it is revealed that the breakdown field strength is the essential factor in plasma channel creation. The heterogeneity of the particles within the rock and the fluctuation in electrode settings are also significant variables influencing the creation of channels. The presented model contributes to a better understanding of the mechanism of rock fragmentation during high-voltage electrical pulses, which has substantial implications for oil exploration and mineral extraction

    Mechanism Analysis of Rock Failure Process under High-Voltage Electropulse: Analytical Solution and Simulation

    No full text
    This work aims to investigate and analyse the mechanism of rock failure under high-voltage electropulses in order to evaluate and increase the efficiency of high-voltage pulse technology in geological well drilling, tunnel boring, and other geotechnical engineering applications. To this end, this paper discusses the equivalent circuit of electric pulse rock breaking, the model of shock wave in electro channel plasma, and, particularly, the model of rock failure in order to disclose the rock failure process when exposed to high-voltage electropulse. This article uses granite as an example to present an analytical approach for predicting the mechanical behaviour of high-voltage electropulses and to analyse the damage that occurs. A numerical model based on equivalent circuit, shock wave model, and elasto-brittle failure criterion is developed for granite under electropulse to further examine the granite failure process. Under the conditions described in this study, and using granite as an example, the granite is impacted by a discharge device (Marx generator) with an initial voltage U0 that is 10 kV and a capacitance F that is 5 µF before it begins to degrade at about 40 µs after discharge, with the current reaching its peak at approximately 50 µs. The shock wave pressure then attains a peak at about 70 µs. Dense short cracks form around granite and the dominant cracks grow to an average length of about 20 cm at around 200 µs. The crack width dcr is predicted to be approximately 1.6 mm. This study detects dense cracks in a few centimetres surrounding the borehole, while around seven dominant cracks expand outward. The distribution of the length of the dominating cracks can be inhomogeneous because of the spatial heterogeneity of granite’s tensile strength, however the heterogeneity has an insignificant effect on the crack growth rate, total cracked area, or the number of main cracks. The mechanism of rock failure under electropulse can be well supported by the findings of numerical simulations and analytical studies