336 research outputs found

    Ecal X5 Gif User Manual

    Get PDF
    This note describes the ECAL Gamma Irradiation Facility (GIF) set-up and how to identify and handle the different parts. It provides an action check list in order to avoid damage to the apparatus and to use it effectively. It describes the set-up in January 2000. A web version which will be updated when needed is available on CMS LAPP team site on LAPP web page at http://wwwlapp.in2p3.fr/cms/GIFUSERMANUAL-X5.html

    A new experiment to search for the invisible decay of the orthopositronium

    Full text link
    We propose an experiment to search for invisible decays of orthopositronium (o-Ps) with a 90% confidence sensitivity in the branching ratio as low as 10−810^{-8}. Evidence for this decay mode would unambigously signal new physics: either the existence of extra--dimensions or fractionally charged particles or new light gauge bosons. The experimental approach and the detector components of the proposed experiment are described.Comment: Based on a talk given at Workshop on Positronium Physics, Zurich, Switzerland, 30-31 May 200

    A facility for the test of large area muon chambers at high rates

    Get PDF
    Operation of large area muon detectors at the future Large Hadron Collider (LHC) will be characterized by large sustained hit rates over the whole area, reaching the range of kHz/\scm. We describe a dedicated test zone built at CERN to test the performance and the aging of the muon chambers currently under development. A radioactive source delivers photons causing the sustained rate of random hits, while a narrow beam of high energy muons is used to directly calibrate the detector performance. A system of remotely controlled lead filters serves to vary the rate of photons over four orders of magnitude, to allow the study of performance as a function of rate

    Encoding difficulty promotes postlearning changes in sleep spindle activity during napping

    Full text link
    Learning-dependent increases in sleep spindle density have been reported during nocturnal sleep immediately after the learning session. Here, we investigated experience-dependent changes in daytime sleep EEG activity after declarative learning of unrelated word pairs. At weekly intervals, 13 young male volunteers spent three 24 h sessions in the laboratory under carefully controlled homeostatic and circadian conditions. At approximately midday, subjects performed either one of two word-pair learning tasks or a matched nonlearning control task, in a counterbalanced order. The two learning lists differed in the level of concreteness of the words used, resulting in an easier and a more difficult associative encoding condition, as confirmed by performance at immediate cued recall. Subjects were then allowed to sleep for 4 h; afterward, delayed cued recall was tested. Compared with the control condition, sleep EEG spectral activity in the low spindle frequency range and the density of low-frequency sleep spindles (11.25-13.75 Hz) were both significantly increased in the left frontal cortex after the difficult but not after the easy encoding condition. Furthermore, we found positive correlations between these EEG changes during sleep and changes in memory performance between pre-nap and post-nap recall sessions. These results indicate that, like during nocturnal sleep, daytime sleep EEG oscillations including spindle activity are modified after declarative learning of word pairs. Furthermore, we demonstrate here that the nature of the learning material is a determinant factor for sleep-related alterations after declarative learning

    Study of the ηπo\eta\pi^o system in the mass range up to 1200 MeV

    Full text link
    The reaction π−p→ηπon\pi^-p \to \eta\pi^o n has been studied with GAMS-2000 spectrometer in the secondary 38 GeV/c π−\pi^--beam of the IHEP U-70 accelerator. Partial wave analysis of the reaction has been performed in the ηπo\eta\pi^o mass range up to 1200 MeV. The a0(980)a_0(980)-meson is seen as a sharp peak in S-wave. The tt-dependence of a0(980)a_0(980) production cross section has been studied. Dominant production of the a0(980)a_0(980) at a small transfer momentum tt confirms the hypothesis of Achasov and Shestakov about significant contribution of the ρ2\rho_2 exchange (IGJPC=1+2−−I^GJ^{PC}=1^+2^{--}) in the mechanism of a0(980)a_0(980) meson production in tt-channel of the reaction.Comment: 4 pages, 3 figures, talk given at HADRON'9

    Biomimetic Magnetic Nanocarriers Drive Choline Kinase Alpha Inhibitor inside Cancer Cells for Combined Chemo-Hyperthermia Therapy

    Get PDF
    Choline kinase a1 (ChoKa1) has become an excellent antitumor target. Among all the inhibitors synthetized, the new compound Ff35 shows an excellent capacity to inhibit ChoKa1 activity. However, soluble Ff35 is also capable of inhibiting choline uptake, making the inhibitor not selective for ChoKa1. In this study, we designed a new protocol with the aim of disentangling whether the Ff35 biological action is due to the inhibition of the enzyme and/or to the choline uptake. Moreover, we offer an alternative to avoid the inhibition of choline uptake caused by Ff35, since the coupling of Ff35 to novel biomimetic magnetic nanoparticles (BMNPs) allows it to enter the cell through endocytosis without interacting with the choline transporter. This opens the possibility of a clinical use of Ff35. Our results indicate that Ff35-BMNPs nanoassemblies increase the selectivity of Ff35 and have an antiproliferative effect. Also, we demonstrate the effectiveness of the tandem Ff35-BMNPs and hyperthermia.This research was funded by the Ministerio de EconomĂ­a y Competitividad (CGL2013-46612 and CGL2016-76723 projects), RamĂłn y Cajal programme (RYC-2014-16901) and the Fondo Europeo de Desarrollo Regional (FEDER). Also, this research was aided by the Andalusian regional government (CTS-236)

    Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter

    Get PDF
    This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPEnsuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered

    Sleepiness at the wheel across Europe: a survey of 19 countries

    Get PDF
    The European Sleep Research Society aimed to estimate the prevalence, determinants and consequences of falling asleep at the wheel. In total, 12 434 questionnaires were obtained from 19 countries using an anonymous online questionnaire that collected demographic and sleep‐related data, driving behaviour, history of drowsy driving and accidents. Associations were quantified using multivariate logistic regression. The average prevalence of falling asleep at the wheel in the previous 2 years was 17%. Among respondents who fell asleep, the median prevalence of sleep‐related accidents was 7.0% (13.2% involved hospital care and 3.6% caused fatalities). The most frequently perceived reasons for falling asleep at the wheel were poor sleep in the previous night (42.5%) and poor sleeping habits in general (34.1%). Falling asleep was more frequent in the Netherlands [odds ratio = 3.55 (95% confidence interval: 1.97; 6.39)] and Austria [2.34 (1.75; 3.13)], followed by Belgium [1.52 (1.28; 1.81)], Portugal [1.34 (1.13, 1.58)], Poland [1.22 (1.06; 1.40)] and France [1.20 (1.05; 1.38)]. Lower odds were found in Croatia [0.36 (0.21; 0.61)], Slovenia [0.62 (0.43; 0.89)] and Italy [0.65 (0.53; 0.79)]. Individual determinants of falling asleep were younger age; male gender [1.79 (1.61; 2.00)]; driving ≄20 000 km year [2.02 (1.74; 2.35)]; higher daytime sleepiness [7.49 (6.26; 8.95)] and high risk of obstructive sleep apnea syndrome [3.48 (2.78; 4.36) in men]. This Pan European survey demonstrates that drowsy driving is a major safety hazard throughout Europe. It emphasizes the importance of joint research and policy efforts to reduce the burden of sleepiness at the wheel for European drivers
    • 

    corecore