75 research outputs found
Spectral Lag Relations in GRB Pulses Detected with HETE-2
Using a pulse-fit method, we investigate the spectral lags between the
traditional gamma-ray band (50-400 keV) and the X-ray band (6-25 keV) for 8
GRBs with known redshifts (GRB 010921, GRB 020124, GRB 020127, GRB 021211, GRB
030528, GRB 040924, GRB 041006, GRB 050408) detected with the WXM and FREGATE
instruments aboard the HETE-2 satellite. We find several relations for the
individual GRB pulses between the spectral lag and other observables, such as
the luminosity, pulse duration, and peak energy (Epeak). The obtained results
are consistent with those for BATSE, indicating that the BATSE correlations are
still valid at lower energies (6-25 keV). Furthermore, we find that the photon
energy dependence for the spectral lags can reconcile the simple curvature
effect model. We discuss the implication of these results from various points
of view.Comment: 13 pages, 9 figures, accepted for the publication in PASJ (minor
corrections
Almost one year of TROPOMI/S5P total ozone column data: global ground-based validation
Póster presentado en: ATMOS 2018, celebrado en Salzburgo (Austria) del 26 al 29 de noviembre de 2018.In this work we present the validation results of almost one year of TROPOMI Near Real Time (NRTI) and OFFLine (OFFL) data against ground-based quality-assured Brewer and Dobson total ozone column (TOC) measurements deposited in the World Ozone and Ultraviolet Radiation Data Center (WOUDC). Additionally, comparisons to Brewer measurements from the European Brewer Network (EUBREWNET) and the Canadian Network are performed, as well as to twilight zenith-sky measurements obtained with ZSL-DOAS (Zenith Scattered Light Differential Optical Absorption Spectroscopy) instruments, that form part of the SAOZ network (Système d'Analyse par Observation Zénitale) of the Network for the Detection of Atmospheric Composition Change (NDACC). Through the comparison of the TROPOMI measurements to the total ozone ground-based measurements from stations that are distributed globally, as the background truth, the dependence of the new instrument on latitude, cloud properties, solar zenith and viewing angles, among others, is examined. Validation results show that the mean bias and the standard deviation of the percentage difference between TROPOMI and QA ground TOC meet the product requirements
Validation of ACE and OSIRIS ozone and NO2 measurements using ground-based instruments at 80 degrees N
The Optical Spectrograph and Infra-Red Imager System (OSIRIS) and the Atmospheric Chemistry Experiment (ACE) have been taking measurements from space since 2001 and 2003, respectively. This paper presents intercomparisons between ozone and NO2 measured by the ACE and OSIRIS satellite instruments and by ground-based instruments at the Polar Environment Atmospheric Research Laboratory (PEARL), which is located at Eureka, Canada (80A degrees N, 86A degrees W) and is operated by the Canadian Network for the Detection of Atmospheric Change (CANDAC). The ground-based instruments included in this study are four zenith-sky differential optical absorption spectroscopy (DOAS) instruments, one Bruker Fourier transform infrared spectrometer (FTIR) and four Brewer spectrophotometers. Ozone total columns measured by the DOAS instruments were retrieved using new Network for the Detection of Atmospheric Composition Change (NDACC) guidelines and agree to within 3.2%. The DOAS ozone columns agree with the Brewer spectrophotometers with mean relative differences that are smaller than 1.5%. This suggests that for these instruments the new NDACC data guidelines were successful in producing a homogenous and accurate ozone dataset at 80A degrees N. Satellite 14-52 km ozone and 17-40 km NO2 partial columns within 500 km of PEARL were calculated for ACE-FTS Version 2.2 (v2.2) plus updates, ACE-FTS v3.0, ACE-MAESTRO (Measurements of Aerosol Extinction in the Stratosphere and Troposphere Retrieved by Occultation) v1.2 and OSIRIS SaskMART v5.0x ozone and Optimal Estimation v3.0 NO2 data products. The new ACE-FTS v3.0 and the validated ACE-FTS v2.2 partial columns are nearly identical, with mean relative differences of 0.0 +/- 0.2% and -0.2 +/- 0.1% for v2.2 minus v3.0 ozone and NO2, respectively. Ozone columns were constructed from 14-52 km satellite and 0-14 km ozonesonde partial columns and compared with the ground-based total column measurements. The satellite-plus-sonde measurements agree with the ground-based ozone total columns with mean relative differences of 0.1-7.3%. For NO2, partial columns from 17 km upward were scaled to noon using a photochemical model. Mean relative differences between OSIRIS, ACE-FTS and ground-based NO2 measurements do not exceed 20%. ACE-MAESTRO measures more NO2 than the other instruments, with mean relative differences of 25-52%. Seasonal variation in the differences between NO2 partial columns is observed, suggesting that there are systematic errors in the measurements and/or the photochemical model corrections. For ozone spring-time measurements, additional coincidence criteria based on stratospheric temperature and the location of the polar vortex were found to improve agreement between some of the instruments. For ACE-FTS v2.2 minus Bruker FTIR, the 2007-2009 spring-time mean relative difference improved from -5.0 +/- 0.4% to -3.1 +/- 0.8% with the dynamical selection criteria. This was the largest improvement, likely because both instruments measure direct sunlight and therefore have well-characterized lines-of-sight compared with scattered sunlight measurements. For NO2, the addition of a +/- 1A degrees latitude coincidence criterion improved spring-time intercomparison results, likely due to the sharp latitudinal gradient of NO2 during polar sunrise. The differences between satellite and ground-based measurements do not show any obvious trends over the missions, indicating that both the ACE and OSIRIS instruments continue to perform well
An unprecedented arctic ozone depletion event during spring 2020 and its impacts across Europe
The response of the ozone column across Europe to the extreme 2020 Arctic ozone depletion was examined by analyzing ground-based observations at 38 European stations. The ozone decrease at the northernmost site, Ny-Ålesund (79°N) was about 43% with respect to a climatology of more than 30 years. The magnitude of the decrease declined by about 0.7% deg−1 moving south to reach nearly 15% at 40°N. In addition, it was found that the variations of the ozone column at each of the selected stations in March-May were similar to those observed at Ny-Ålesund but with a delay increasing to about 20 days at mid-latitudes with a gradient of approximately 0.5 days deg−1. The distributions of reconstructed ozone column anomalies over a sector covering a large European area show decreasing ozone that started from the north at the beginning of April 2020 and spread south. Such behavior was shown to be similar to that observed after the Arctic ozone depletion in 2011. Stratospheric dynamical patterns in March–May 2011 and during 2020 suggested that the migration of ozone-poor air masses from polar areas to the south after the vortex breakup caused the observed ozone responses. A brief survey of the ozone mass mixing ratios at three stratospheric levels showed the exceptional strength of the 2020 episode. Despite the stronger and longer-lasting Arctic ozone loss in 2020, the analysis in this work indicates a similar ozone response at latitudes below 50°N to both 2011 and 2020 phenomena
Robotic Living Donor Right Hepatectomy: A Systematic Review and Meta-Analysis
The introduction of robotics in living donor liver transplantation has been revolutionary. We aimed to examine the safety of robotic living donor right hepatectomy (RLDRH) compared to open (ODRH) and laparoscopic (LADRH) approaches. A systematic review was carried out in Medline and six additional databases following PRISMA guidelines. Data on morbidity, postoperative liver function, and pain in donors and recipients were extracted from studies comparing RLDRH, ODRH, and LADRH published up to September 2020; PROSPERO (CRD42020214313). Dichotomous variables were pooled as risk ratios and continuous variables as weighted mean differences. Four studies with a total of 517 patients were included. In living donors, the postoperative total bilirubin level (MD: −0.7 95%CI −1.0, −0.4), length of hospital stay (MD: −0.8 95%CI −1.4, −0.3), Clavien–Dindo complications I–II (RR: 0.5 95%CI 0.2, 0.9), and pain score at day > 3 (MD: −0.6 95%CI −1.6, 0.4) were lower following RLDRH compared to ODRH. Furthermore, the pain score at day > 3 (MD: −0.4 95%CI −0.8, −0.09) was lower after RLDRH when compared to LADRH. In recipients, the postoperative AST level was lower (MD: −0.5 95%CI −0.9, −0.1) following RLDRH compared to ODRH. Moreover, the length of stay (MD: −6.4 95%CI −11.3, −1.5) was lower after RLDRH when compared to LADRH. In summary, we identified low- to unclear-quality evidence that RLDRH seems to be safe and feasible for adult living donor liver transplantation compared to the conventional approaches. No postoperative deaths were reported
Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries.
BACKGROUND: As global initiatives increase patient access to surgical treatments, there remains a need to understand the adverse effects of surgery and define appropriate levels of perioperative care. METHODS: We designed a prospective international 7-day cohort study of outcomes following elective adult inpatient surgery in 27 countries. The primary outcome was in-hospital complications. Secondary outcomes were death following a complication (failure to rescue) and death in hospital. Process measures were admission to critical care immediately after surgery or to treat a complication and duration of hospital stay. A single definition of critical care was used for all countries. RESULTS: A total of 474 hospitals in 19 high-, 7 middle- and 1 low-income country were included in the primary analysis. Data included 44 814 patients with a median hospital stay of 4 (range 2-7) days. A total of 7508 patients (16.8%) developed one or more postoperative complication and 207 died (0.5%). The overall mortality among patients who developed complications was 2.8%. Mortality following complications ranged from 2.4% for pulmonary embolism to 43.9% for cardiac arrest. A total of 4360 (9.7%) patients were admitted to a critical care unit as routine immediately after surgery, of whom 2198 (50.4%) developed a complication, with 105 (2.4%) deaths. A total of 1233 patients (16.4%) were admitted to a critical care unit to treat complications, with 119 (9.7%) deaths. Despite lower baseline risk, outcomes were similar in low- and middle-income compared with high-income countries. CONCLUSIONS: Poor patient outcomes are common after inpatient surgery. Global initiatives to increase access to surgical treatments should also address the need for safe perioperative care. STUDY REGISTRATION: ISRCTN5181700
A simplified (modified) Duke Activity Status Index (M-DASI) to characterise functional capacity: A secondary analysis of the Measurement of Exercise Tolerance before Surgery (METS) study
Background
Accurate assessment of functional capacity, a predictor of postoperative morbidity and mortality, is essential to improving surgical planning and outcomes. We assessed if all 12 items of the Duke Activity Status Index (DASI) were equally important in reflecting exercise capacity.
Methods
In this secondary cross-sectional analysis of the international, multicentre Measurement of Exercise Tolerance before Surgery (METS) study, we assessed cardiopulmonary exercise testing and DASI data from 1455 participants. Multivariable regression analyses were used to revise the DASI model in predicting an anaerobic threshold (AT) >11 ml kg −1 min −1 and peak oxygen consumption (VO 2 peak) >16 ml kg −1 min −1, cut-points that represent a reduced risk of postoperative complications.
Results
Five questions were identified to have dominance in predicting AT>11 ml kg −1 min −1 and VO 2 peak>16 ml.kg −1min −1. These items were included in the M-DASI-5Q and retained utility in predicting AT>11 ml.kg −1.min −1 (area under the receiver-operating-characteristic [AUROC]-AT: M-DASI-5Q=0.67 vs original 12-question DASI=0.66) and VO 2 peak (AUROC-VO2 peak: M-DASI-5Q 0.73 vs original 12-question DASI 0.71). Conversely, in a sensitivity analysis we removed one potentially sensitive question related to the ability to have sexual relations, and the ability of the remaining four questions (M-DASI-4Q) to predict an adequate functional threshold remained no worse than the original 12-question DASI model. Adding a dynamic component to the M-DASI-4Q by assessing the chronotropic response to exercise improved its ability to discriminate between those with VO 2 peak>16 ml.kg −1.min −1 and VO 2 peak<16 ml.kg −1.min −1.
Conclusions
The M-DASI provides a simple screening tool for further preoperative evaluation, including with cardiopulmonary exercise testing, to guide perioperative management
- …