2 research outputs found
Comparison of Gamma Index Passing Rate in Several Treatment Planning System Algorithms
The verification of dose calculation algorithm in a new Treatment Planning System (TPS) can be evaluated by comparing the passing rate of the gamma index analysis of the evaluated algorithm and the clinically implemented algorithms. In the present investigation, the gamma index passing rates was investigated as the reference data in the verification of the new three-dimensional TPS. The algorithms which are used in this study are Pencil Beam Convolution (PBC) version 11.0.31 and Anisotropic Analytical Algorithm (AAA) version 11.0.31 in Eclipse v.11 TPS, and Fast Convolution (FC), Adaptive Convolution (AC), and Collapsed-Cone Convolution (CCC) in Pinnacle3 v.7.6c TPS. The 6 MV X-ray beam configurations were varied in the depth of measurement points, field sizes, source-to-surface distances, and wedge angles. The dose measurement was done using MatriXX Evolution and PTW 2D-array seven29. Then, OmniPro ImRT and Verisoft 3.1 software were chosen to analyze the gamma index from varied gamma criteria (3 %/3mm, 2 %/3mm, 3 %/2mm, and 2 %/2mm). Overall, the passing rate of AAA is the highest rate obtained of all algorithms. For gamma criterion of 2 %/2mm, the passing rate of AAA was 93.18 % ± 7.21 %, the passing rate of PBC was 89.76 % ± 7.21 %, and the passing rate of convolution algorithms was 76.84 % ± 11.10 %
Determination of the Dosimetric Characteristics of BATAN’s 125I Source for Brachytherapy: An Experimental Study
125I brachytherapysources withlowphotonenergies have beenwidelyusedin treatingtumors.Accordingto American Association of Physicists in Medicine Task Group No. 43 (AAPMTG-43)recommendations,dosimetric characteristic ofthe newbrachytherapysources shouldbe determined before clinical use.Inthis study, dosimetric characteristic of 125Imanufacturedby BATAN have been determined through measurement by using Thermoluminescent Dosemeter (TLD) andgafchromic XR- QA2film.The radial dosefunctionmeasurements were performedat distances rangingfrom0.5to10cmfromthe source center.The anisotropyfunctions were measuredat distances of2,3,and5cmfromthe source center forangles ranging from0to 90degree inallquadrants.The results indicated that a doserate constants measured with TLD and film are 1.05± 8 % cGy.h-1.U-1and1.01±8 % cGy.h-1.U-1, respectively.The radial dosefunctiondecreasesalongwith the increasingdistance from source andmeetsthe 5thorderpolynomial equation. The anisotropyfunction resultshows thattheanisotropyindosedistributionincreasesalongthe source axis.Thismeasurement data areinagreementwith the previousstudy on EGSnrc Monte Carloresult andhave a similar patternwithIsoAidandGMS BT-125 commercial125Isource