2,985 research outputs found
So you're planning a baby?: a review of preconception care apps
Previous research shows couples favour online information sources when seeking support for preconception health and pregnancy planning, with mobile applications (apps) becoming increasingly popular. This study aimed to establish what smartphone apps currently exist to support couples when preparing for pregnancy. A functionality review was conducted to explore app content and an analysis of user reviews was undertaken to investigate user views towards existing apps. 25 apps were analysed, which provided information on diet, weight, alcohol, smoking and caffeine amongst others. Positive reviews mainly referred to the helpfulness of the app. Negative comments focused on the over simplification of information. Overall, user comments showed a positive response towards existing preconception care apps, but users reported concerns towards information accuracy and reliability. Further work will be undertaken to evaluate whether existing apps engage users to improve their preconception health care and whether these apps fulfils user requirements
Mechanism of faster NO scavenging by older stored red blood cells
The blood storage lesion involves morphological and biochemical changes of red blood cells (RBCs) that occur during storage. These include conversion of the biconcave disc morphology to a spherical one, decreased mean corpuscular hemoglobin concentration, varied mean corpuscular volume, reduced integrity of the erythrocyte membrane with formation of microparticles, and increased cell-free hemoglobin. We studied the extent that older stored red blood cells scavenge nitric oxide (NO) faster than fresher stored red blood cells. Using electron paramagnetic resonance spectroscopy and stopped-flow absorption spectroscopy to measure the rate of NO uptake and reaction with hemoglobin in red cells, we found that older stored red blood cells scavenge NO about 1.8 times faster than fresher ones. Based on these experimental data, we simulated NO scavenging by fresher or older stored red blood cells with a biconcave or spherical geometry, respectively, in order to explore the mechanism of NO scavenging related to changes that occur during blood storage. We found that red blood cells with a spherical geometry scavenges NO about 2 times slower than ones with a biconcave geometry, and a smaller RBC hemoglobin concentration or volume increases NO scavenging by red blood cells. Our simulations demonstrate that even the most extreme possible changes in mean corpuscular hemoglobin concentration and mean corpuscular volume that favor increased NO scavenging are insufficient to account for what is observed experimentally. Therefore, RBC membrane permeability must increase during storage and we find that the permeability is likely to increase between 5 and 70 fold. Simulations using a two-dimensional blood vessel show that even a 5-fold increase in membrane permeability to NO can reduce NO bioavailability at the smooth muscle. Background: Transfusion of older stored blood may be harmful. Results: Older stored red blood cells scavenge nitric oxide more than fresher cells. Conclusion: As stored red blood cells age, structural and biochemical changes occur that lead to faster scavenging. Significance: Increased nitric oxide scavenging by red blood cells as a function of storage age contributes to deleterious effects upon transfusion. © 2014 The Authors
Properties of Light Flavour Baryons in Hypercentral quark model
The light flavour baryons are studied within the quark model using the hyper
central description of the three-body system. The confinement potential is
assumed as hypercentral coulomb plus power potential () with power
index . The masses and magnetic moments of light flavour baryons are
computed for different power index, starting from 0.5 to 1.5. The
predicted masses and magnetic moments are found to attain a saturated value
with respect to variation in beyond the power index 1.0. Further
we computed transition magnetic moments and radiative decay width of light
flavour baryons. The results are in good agreement with known experimental as
well as other theoretical models.Comment: Accepted in Pramana J. of Physic
Learning curves and long-term outcome of simulation-based thoracentesis training for medical students
<p>Abstract</p> <p>Background</p> <p>Simulation-based medical education has been widely used in medical skills training; however, the effectiveness and long-term outcome of simulation-based training in thoracentesis requires further investigation. The purpose of this study was to assess the learning curve of simulation-based thoracentesis training, study skills retention and transfer of knowledge to a clinical setting following simulation-based education intervention in thoracentesis procedures.</p> <p>Methods</p> <p>Fifty-two medical students were enrolled in this study. Each participant performed five supervised trials on the simulator. Participant's performance was assessed by performance score (PS), procedure time (PT), and participant's confidence (PC). Learning curves for each variable were generated. Long-term outcome of the training was measured by the retesting and clinical performance evaluation 6 months and 1 year, respectively, after initial training on the simulator.</p> <p>Results</p> <p>Significant improvements in PS, PT, and PC were noted among the first 3 to 4 test trials (p < 0.05). A plateau for PS, PT, and PC in the learning curves occurred in trial 4. Retesting 6 months after training yielded similar scores to trial 5 (p > 0.05). Clinical competency in thoracentesis was improved in participants who received simulation training relative to that of first year medical residents without such experience (p < 0.05).</p> <p>Conclusions</p> <p>This study demonstrates that simulation-based thoracentesis training can significantly improve an individual's performance. The saturation of learning from the simulator can be achieved after four practice sessions. Simulation-based training can assist in long-term retention of skills and can be partially transferred to clinical practice.</p
Successful ACL reconstruction with a variant of the pes anserinus
An anatomical variant of the pes anserinus encountered during anterior cruciate ligament reconstructive surgery which has not been previously described is discussed. During routine harvesting, the sartorius fascia was incised and the semitendinosus and gracilis tendons were identified. At the distal portion, it was noted that each tendon gave off an additional tendinous slip. The slip from the semitendinosus tendon had attached to the gracilis tendon and vice versa, thereby creating a double pes anserinus. This variant was used to construct the graft, and at 1 year review the patient had returned to full sporting activities with no complications encountered
Considering the influence of coronary motion on artery-specific biomechanics using fluid-structure interaction simulation
The endothelium in the coronary arteries is subject to wall shear stress and vessel wall strain, which influences the biology of the arterial wall. This study presents vessel-specific fluid-structure interaction (FSI) models of three coronary arteries, using directly measured experimental geometries and boundary conditions. FSI models are used to provide a more physiologically complete representation of vessel biomechanics, and have been extended to include coronary bending to investigate its effect on shear and strain. FSI both without- and with-bending resulted in significant changes in all computed shear stress metrics compared to CFD (p = 0.0001). Inclusion of bending within the FSI model produced highly significant changes in Time Averaged Wall Shear Stress (TAWSS) + 9.8% LAD, + 8.8% LCx, - 2.0% RCA; Oscillatory Shear Index (OSI) + 208% LAD, 0% LCx, + 2600% RCA; and transverse wall Shear Stress (tSS) + 180% LAD, + 150% LCx and + 200% RCA (all p < 0.0001). Vessel wall strain was homogenous in all directions without-bending but became highly anisotropic under bending. Changes in median cyclic strain magnitude were seen for all three vessels in every direction. Changes shown in the magnitude and distribution of shear stress and wall strain suggest that bending should be considered on a vessel-specific basis in analyses of coronary artery biomechanics
Clinical and molecular characterization of a novel PLIN1 frameshift mutation identified in patients with familial partial lipodystrophy.
Perilipin 1 is a lipid droplet coat protein predominantly expressed in adipocytes, where it inhibits basal and facilitates stimulated lipolysis. Loss-of-function mutations in the PLIN1 gene were recently reported in patients with a novel subtype of familial partial lipodystrophy, designated as FPLD4. We now report the identification and characterization of a novel heterozygous frameshift mutation affecting the carboxy-terminus (439fs) of perilipin 1 in two unrelated families. The mutation cosegregated with a similar phenotype including partial lipodystrophy, severe insulin resistance and type 2 diabetes, extreme hypertriglyceridemia, and nonalcoholic fatty liver disease in both families. Poor metabolic control despite maximal medical therapy prompted two patients to undergo bariatric surgery, with remarkably beneficial consequences. Functional studies indicated that expression levels of the mutant protein were lower than wild-type protein, and in stably transfected preadipocytes the mutant protein was associated with smaller lipid droplets. Interestingly, unlike the previously reported 398 and 404 frameshift mutants, this variant binds and stabilizes ABHD5 expression but still fails to inhibit basal lipolysis as effectively as wild-type perilipin 1. Collectively, these findings highlight the physiological need for exquisite regulation of neutral lipid storage within adipocyte lipid droplets, as well as the possible metabolic benefits of bariatric surgery in this serious disease.Wellcome TrustThis is the author accepted manuscript. The final version is available from the American Diabetes Association via http://dx.doi.org/10.2337/db14-010
Transient peak-strain matching partially recovers the age-impaired mechanoadaptive cortical bone response
Mechanoadaptation maintains bone mass and architecture; its failure underlies age-related decline in bone strength. It is unclear whether this is due to failure of osteocytes to sense strain, osteoblasts to form bone or insufficient mechanical stimulus. Mechanoadaptation can be restored to aged bone by surgical neurectomy, suggesting that changes in loading history can rescue mechanoadaptation. We use non-biased, whole-bone tibial analyses, along with characterisation of surface strains and ensuing mechanoadaptive responses in mice at a range of ages, to explore whether sufficient load magnitude can activate mechanoadaptation in aged bone. We find that younger mice adapt when imposed strains are lower than in mature and aged bone. Intriguingly, imposition of short-term, high magnitude loading effectively primes cortical but not trabecular bone of aged mice to respond. This response was regionally-matched to highest strains measured by digital image correlation and to osteocytic mechanoactivation. These data indicate that aged bone’s loading response can be partially recovered, non-invasively by transient, focal high strain regions. Our results indicate that old murine bone does respond to load when the loading is of sufficient magnitude, and bones’ age-related adaptation failure may be due to insufficient mechanical stimulus to trigger mechanoadaptation
Comparison of spontaneous with controlled mode of ventilation in tonsillectomy
Methods: This randomized study compares spontaneous versus controlled ventilation in 60 ASA I and II patients undergoing tonsillectomy as regards haemodynamic stability, recovery characteristics, intra- and immediate postoperative complications and surgical impressions.Results: The patients in the balanced anaesthesia (B) group showed less haemodynamic variability compared to baseline after tracheal intubation, mouth gag application and removal and incision. Two patients had dysrhythmias in the B group compared to six in the spontaneous breathing (S) group. Six patients in the S group had a rise in endtidal carbon dioxide concentration above 7.8 kPa (60 mmHg). Recovery scores were higher in the B group at 10 and 20 min into recovery. The surgical impression of bleeding and jaw relaxation was similar with both groups. The incidence of postoperative nausea and vomiting and agitation was higher in the S group but did not achieve statistical significance.CONCLUSION: Use of balanced anaesthesia offered more haemodynamic stability and a rapid recovery
The Role of Health Systems Factors in Facilitating Access to Psychotropic Medicines: A Cross-Sectional Analysis of the WHO-AIMS in 63 Low- and Middle-Income Countries
In a cross-sectional analysis of WHO-AIMS data, Ryan McBain and colleagues investigate the associations between health system components and access to psychotropic drugs in 63 low and middle income countries
- …