24 research outputs found

    Safe chest tube placement in a patient with tension pneumothorax receiving rivaroxaban therapy for non-valvular atrial fibrillation

    No full text
    The number of patients treated with direct oral anticoagulants is increasing worldwide. Although bleeding complications associated with direct oral anticoagulants are lower than those associated with vitamin K antagonists, the increased number of patients treated with these anticoagulants suggests that a higher absolute number of patients are at risk. Tube thoracostomy is an invasive procedure with a high risk of bleeding. To date, among direct oral anticoagulants, only dabigatran has a well-studied antidote to reverse its effects during emergency procedure or surgery. This report describes a case in which emergency placement of a tube thoracostomy, in a patient with type 2 respiratory failure due to left tension pneumothorax and receiving the anticoagulant rivaroxaban, in the pharmacokinetics phase with greater anticoagulant effect, did not result in bleeding greater than that typically encountered during such interventions. The procedure ended successfully with no acute complications

    His-bundle pacing to treat an unusual case of chest pain after pacemaker implant

    No full text
    A 63-year-old man with hypertension and 3-vessel coronary artery disease previously treated with coronary artery bypass graft was admitted to our emergency room complaining of chest pain. He had undergone pacemaker implant 5 months before due to paroxysmal advanced atrioventricular block. Electrocardiography and troponin testing were unremarkable. Echocardiography and chest X-ray ruled out lead displacement and perforation. Interrogation showed normal parameters [right atrium: impedance 550 Ohm bipolar, sensing 2.4 mV bipolar; threshold 0.50 V/0.4 ms bipolar; right ventricle (RV): impedance 580 Ohm bipolar, sensing > 25 mV bipolar; threshold 1.5 V/0.4 ms bipolar and 0.4 V/0.4 ms unipolar]. Pain was evoked only during RV pacing. An electrophysiology study demonstrated painful RV pacing from multiple sites. We hypothesized that pain was associated with pacing-induced dyssynchrony. His-bundle pacing (HBP) was considered as a solution. We achieved HBP with a bipolar fixed-screw catheter connected to a cardiac resynchronization therapy pacemaker generator. During HBP above threshold (4.00 V/1.00 ms) the patient did not complain of any pain. He was discharged 3 days later pain-free with His-bundle lead amplitude set at 5.00 V/1.00 ms. After 6 months the patient was asymptomatic, with the device showing normal functioning. This is the first clinical experience of painful RV pacing treated with HBP. Learning objective: Painful right ventricular pacing in the absence of perforation is a rare but potentially underdiagnosed condition. Ventricular dyssynchrony could represent the underlying mechanism. Physiological electromechanical activation achieved via His-bundle pacing could represent an effective therapeutic option

    Standard versus strict stability criteria in radiofrequency paroxysmal atrial fibrillation ablation using ablation index

    No full text
    Purpose: To compare the outcome of paroxysmal atrial fibrillation (AF) ablation via pulmonary vein isolation using Ablation Index (AI) with strict or standard stability criteria. Methods: We enrolled 130 consecutive naive patients affected by paroxysmal AF who underwent PVI at two high-volume centers. AI target was ≥380 at the posterior wall and ≥500 at the anterior wall. Strict versus standard stability criteria were set for Group 1 (65 patients) and Group 2 (65 patients), respectively. We compared those strategies with a historical cohort of 72 consecutive patients treated at same centers in the VISITALY study, using average force ≥10 g and strict stability criteria as target parameters. Interlesion distance target was <6 mm. Recurrence was defined as any AF, atrial tachycardia (AT) or atrial flutter (AFL) during the 12 months after ablation, excluding a 90-days blanking period. Results: Procedure duration (224.05 ± 47.21 vs. 175.61 ± 51.29 min; p <.001), fluoroscopy time (11.85 ± 4.38 vs. 10.46 ± 6.49 min; p =.019) and pericardial effusion rate (9.23% vs. 0%; p =.01) were higher in Group 1 than in Group 2. Freedom from AF/AT/AFL at 12 months was not significantly different (Group 1: 86.15%; Group 2: 90.77%; p =.42). Compared to VISITALY study, there were not significant differences in terms of recurrences. Conclusion: A strategy of PVI using AI with standard stability criteria performed the best in terms of procedure efficiency and safety. Twelve-months arrhythmia-free survival rate was comparable with other strategies pursuing an interlesion distance target <6 mm, regardless of the use of AI

    Leadless pacing in the elderly: Never too old for something new

    No full text
    Rates of cardiac pacemaker implantation rise with age, and, meanwhile, elderly patient may be at great risk of complications, as pneumothorax, lead perforation, or pocket dehiscence. The use of leadless pacemaker could overcome peri- and post-procedural complications related to the presence of transvenous leads and pocket. The study aims to investigate feasibility and outcomes of Micra Transcatheter Pacing System (M-TPS) implantation in elderly, which represents a challenge for conventional cardiac pacing. Between May 2014 and July 2019, 109 patients (88 males, mean age 77.71±9.68 years) underwent M-TPS implantation at our Center, targeting a non-apical site of delivery when feasible. Study population was divided into two groups according to age (group 1 <79 years vs group 2 group 2 380 years). The outcome evaluation included electrical performance at hospital discharge, and during follow-up. In 46/109 cases (34 males, 73.91%) M-TPS was implanted in patients older than 80 years. There were no statistically significant differences between groups for demographics characteristics, except for age. The procedure was performed via the right femoral access in 102/109 cases and was successful in all cases, with no device-related events. No differences were observed between groups in procedure duration, single device delivery, electrical performance at implant and at 12 month F-U. MTP-S implant is an effective and safe procedure in elderly patients, with similar electrical performance and outcome compared with younger patients at mid-term follow-up

    Role of pre-procedural CT imaging on catheter ablation in patients with atrial fibrillation: procedural outcomes and radiological exposure

    No full text
    Background: Cardiac computed tomography (CT) is commonly used to study left atrial (LA) and pulmonary veins (PVs) anatomy before atrial fibrillation (AF) ablation. The aim of the study was to determine the impact of pre-procedural cardiac CT with 3D reconstruction on procedural outcomes and radiological exposure in patients who underwent radiofrequency catheter ablation (RFA) of AF. Methods: In this registry, 493 consecutive patients (age 62 ± 8 years, 70% male) with paroxysmal (316) or persistent (177) AF who underwent first procedure of RFA were included. A pre-procedural CT scan was obtained in 324 patients (CT group). Antral pulmonary vein isolation was performed in all patients using an open-irrigation-tip catheter with a 3D electroanatomical navigation system. Procedural outcome, including radiological exposure, and clinical outcomes were compared among patients who underwent RFA with (CT group) and without (no CT group) pre-procedural cardiac CT. Results: Acute PV isolation was obtained in all patients, with a comparable overall complication rate between CT and no CT group (4.3% vs 3%, p = 0.7). No differences were observed about mean duration of the procedure (231 ± 60 vs 233 ± 58 min, p = 0.7) and fluoroscopy time (13 ± 10 vs 13 ± 8 min, p = 0.6) among groups. Cumulative radiation dose resulted significantly higher in the CT group compared with no CT group (8.9 ± 24 vs 4.8 ± 15 mSv, P = 0.02). At 1 year, freedom from AF/atrial tachycardia were comparable among groups (CT group, 227/324 (70%), vs no CT group,119/169 (70%), p = ns). Conclusions: Pre-procedural CT does not improve safety and efficacy of AF ablation, increasing significantly the cumulative radiological exposure
    corecore