30 research outputs found
Microvolt T-Wave Alternans and the Risk of Death or Sustained Ventricular Arrhythmias in Patients With Left Ventricular Dysfunction
ObjectivesThis study hypothesized that microvolt T-wave alternans (MTWA) improves selection of patients for implantable cardioverter-defibrillator (ICD) prophylaxis, especially by identifying patients who are not likely to benefit.BackgroundMany patients with left ventricular dysfunction are now eligible for prophylactic ICDs, but most eligible patients do not benefit; MTWA testing has been proposed to improve patient selection.MethodsOur study was conducted at 11 clinical centers in the U.S. Patients were eligible if they had a left ventricular ejection fraction (LVEF) ≤0.40 and lacked a history of sustained ventricular arrhythmias; patients were excluded for atrial fibrillation, unstable coronary artery disease, or New York Heart Association functional class IV heart failure. Participants underwent an MTWA test and then were followed for about two years. The primary outcome was all-cause mortality or non-fatal sustained ventricular arrhythmias.ResultsIschemic heart disease was present in 49%, mean LVEF was 0.25, and 66% had an abnormal MTWA test. During 20 ± 6 months of follow-up, 51 end points (40 deaths and 11 non-fatal sustained ventricular arrhythmias) occurred. Comparing patients with normal and abnormal MTWA tests, the hazard ratio for the primary end point was 6.5 at two years (95% confidence interval 2.4 to 18.1, p < 0.001). Survival of patients with normal MTWA tests was 97.5% at two years. The strong association between MTWA and the primary end point was similar in all subgroups tested.ConclusionsAmong patients with heart disease and LVEF ≤0.40, MTWA can identify not only a high-risk group, but also a low-risk group unlikely to benefit from ICD prophylaxis
Designing comparative effectiveness trials of surgical ablation for atrial fibrillation: Experience of the Cardiothoracic Surgical Trials Network
ObjectiveSince the introduction of the cut-and-sew Cox maze procedure for atrial fibrillation, there has been substantial innovation in techniques for ablation. Use of alternative energy sources for ablation simplified the procedure and has resulted in dramatic increase in the number of patients with atrial fibrillation treated by surgical ablation. Despite its increasingly widespread adoption, there is lack of rigorous clinical evidence to establish this procedure as an effective clinical therapy.MethodsThis article describes a comparative effectiveness randomized trial, supported by the Cardiothoracic Surgical Clinical Trials Network, of surgical ablation with left atrial appendage closure versus left atrial appendage closure alone in patients with persistent and long-standing persistent atrial fibrillation undergoing mitral valve surgery. Nested within this trial is a further randomized comparison of 2 different lesions sets: pulmonary vein isolation and the full maze lesion set.ResultsThis article addresses trial design challenges, including how best to characterize the target population, operationalize freedom from atrial fibrillation as a primary end point, account for the impact of antiarrhythmic drugs, and measure and analyze secondary end points, such as postoperative atrial fibrillation load.ConclusionsThis article concludes by discussing how insights that emerge from this trial may affect surgical practice and guide future research in this area
Recommended from our members
Probability of atrial fibrillation after ablation: Using a parametric nonlinear temporal decomposition mixed effects model
Atrial fibrillation is an arrhythmic disorder where the electrical signals of the heart become irregular. The probability of atrial fibrillation (binary response) is often time varying in a structured fashion, as is the influence of associated risk factors. A generalized nonlinear mixed effects model is presented to estimate the time-related probability of atrial fibrillation using a temporal decomposition approach to reveal the pattern of the probability of atrial fibrillation and their determinants. This methodology generalizes to patient-specific analysis of longitudinal binary data with possibly time-varying effects of covariates and with different patient-specific random effects influencing different temporal phases. The motivation and application of this model is illustrated using longitudinally measured atrial fibrillation data obtained through weekly trans-telephonic monitoring from an NIH sponsored clinical trial being conducted by the Cardiothoracic Surgery Clinical Trials Network
High-dose ondansetron reduces activation of interoceptive and sensorimotor brain regions
Several psychiatric disorders involve abnormalities of interoception and associated neural circuitry centered on the insula. The development of interventions modulating interoceptive circuits could lead to novel treatment approaches for these disorders. The 5-HT3 receptor antagonist ondansetron is a good candidate for the modulation of interoceptive circuits, as 5-HT3 receptors are located abundantly on sensory pathways and ondansetron has shown some clinical utility in disorders characterized by sensory and interoceptive abnormalities. The present study tested the ability of three different doses of ondansetron to engage neural regions involved in interoception to determine the drug's utility as a therapeutic agent to target circuit abnormalities in patients. Fifty-three healthy subjects were randomized to receive a single 8-mg (n = 18), 16-mg (n = 17), or 24-mg (n = 18) dose of ondansetron and placebo before MRI scanning on separate days. Subjects performed an fMRI task previously shown to engage interoceptive circuitry in which they viewed videos depicting body movements/sensation and control videos. The results revealed a highly significant relationship between dosage and activation in bilateral insula, somatosensory and premotor regions, cingulate cortex, and temporal cortex for control but not body-focused videos. These effects were driven by a robust reduction in activation for ondansetron compared to placebo for the 24-mg group, with weaker effects for the 16-mg and 8-mg groups. In conclusion, high-dose ondansetron reduces activation of several areas important for interoception, including insula and sensorimotor cortical regions. This study reveals the potential utility of this drug in modulating hyperactivity in these regions in patients
Rapid and Longer-Term Antidepressant Effects of Repeated Ketamine Infusions in Treatment-Resistant Major Depression
<p>Background: Ketamine is reported to have rapid antidepressant effects; however, there is limited understanding of the time-course of ketamine effects beyond a single infusion. A previous report including 10 participants with treatment-resistant major depression (TRD) found that six ketamine infusions resulted in a sustained antidepressant effect. In the current report, we examined the pattern and durability of antidepressant effects of repeated ketamine infusions in a larger sample, inclusive of the original.</p><p>Methods: Participants with TRD (n = 24) underwent a washout of antidepressant medication followed by a series of up to six IV infusions of ketamine (.5 mg/kg) administered open-label three times weekly over a 12-day period. Participants meeting response criteria were monitored for relapse for up to 83 days from the last infusion.</p><p>Results: The overall response rate at study end was 70.8%. There was a large mean decrease in Montgomery-Asberg Depression Rating Scale score at 2 hours after the first ketamine infusion (18.9 +/- 6.6, p <.001), and this decrease was largely sustained for the duration of the infusion period. Response at study end was strongly predicted by response at 4 hours (94% sensitive, 71% specific). Among responders, median time to relapse after the last ketamine infusion was 18 days.</p><p>Conclusions: Ketamine was associated with a rapid antidepressant effect in TRD that was predictive of a sustained effect. Future controlled studies will be required to identify strategies to maintain an antidepressant response among patients who benefit from a course of ketamine.</p>
Recommended from our members
Biatrial maze procedure versus pulmonary vein isolation for atrial fibrillation during mitral valve surgery: New analytical approaches and end points
To use novel statistical methods for analyzing the effect of lesion set on (long-standing) persistent atrial fibrillation (AF) in the Cardiothoracic Surgical Trials Network trial of surgical ablation during mitral valve surgery (MVS).
Two hundred sixty such patients were randomized to MVS + surgical ablation or MVS alone. Ablation was randomized between pulmonary vein isolation and biatrial maze. During 12 months postsurgery, 228 patients (88%) submitted 7949 transtelephonic monitoring (TTM) recordings, analyzed for AF, atrial flutter (AFL), or atrial tachycardia (AT). As previously reported, more ablation than MVS-alone patients were free of AF or AF/AFL at 6 and 12 months (63% vs 29%; P < .001) by 72-hour Holter monitoring, without evident difference between lesion sets (for which the trial was underpowered).
Estimated freedom from AF/AFL/AT on any transmission trended higher after biatrial maze than pulmonary vein isolation (odds ratio, 2.31; 95% confidence interval, 0.95-5.65; P = .07) 3 to 12 months postsurgery; estimated AF/AFL/AT load (ie, proportion of TTM strips recording AF/AFL/AT) was similar (odds ratio, 0.90; 95% confidence interval, 0.57-1.43; P = .6). Within 12 months, estimated prevalence of AF/AFL/AT by TTM was 58% after MVS alone, and 36% versus 23% after pulmonary vein isolation versus biatrial maze (P < .02).
Statistical modeling using TTM recordings after MVS in patients with (long-standing) persistent AF suggests that a biatrial maze is associated with lower AF/AFL/AT prevalence, but not a lower load, compared with pulmonary vein isolation. The discrepancy between AF/AFL/AT prevalence assessed at 2 time points by Holter monitoring versus weekly TTM suggests the need for a confirmatory trial, reassessment of definitions for failure after ablation, and validation of statistical methods for assessing atrial rhythms longitudinally