6,154 research outputs found
Measurement of secondary particle production induced by particle therapy ion beams impinging on a PMMA target
Particle therapy is a technique that uses accelerated charged ions for cancer treatment and combines a high irradiation precision with a high biological effectiveness in killing tumor cells [1]. Informations about the secondary particles emitted in the interaction of an ion beam with the patient during a treatment can be of great interest in order to monitor the dose deposition. For this purpose an experiment at the HIT (Heidelberg Ion-Beam Therapy Center) beam facility has been performed in order to measure fluxes and emission profiles of secondary particles produced in the interaction of therapeutic beams with a PMMA target. In this contribution some preliminary results about the emission profiles and the energy spectra of the detected secondaries will be presente
Response of microchannel plates to single particles and to electromagnetic showers
We report on the response of microchannel plates (MCPs) to single
relativistic particles and to electromagnetic showers. Particle detection by
means of secondary emission of electrons at the MCP surface has long been
proposed and is used extensively in ion time-of-flight mass spectrometers. What
has not been investigated in depth is their use to detect the ionizing
component of showers. The time resolution of MCPs exceeds anything that has
been previously used in calorimeters and, if exploited effectively, could aid
in the event reconstruction at high luminosity colliders. Several prototypes of
photodetectors with the amplification stage based on MCPs were exposed to
cosmic rays and to 491 MeV electrons at the INFN-LNF Beam-Test Facility. The
time resolution and the efficiency of the MCPs are measured as a function of
the particle multiplicity, and the results used to model the response to
high-energy showers.Comment: Paper submitted to NIM
Response of microchannel plates in ionization mode to single particles and electromagnetic showers
Hundreds of concurrent collisions per bunch crossing are expected at future
hadron colliders. Precision timing calorimetry has been advocated as a way to
mitigate the pileup effects and, thanks to their excellent time resolution,
microchannel plates (MCPs) are good candidate detectors for this goal. We
report on the response of MCPs, used as secondary emission detectors, to single
relativistic particles and to electromagnetic showers. Several prototypes, with
different geometries and characteristics, were exposed to particle beams at the
INFN-LNF Beam Test Facility and at CERN. Their time resolution and efficiency
are measured for single particles and as a function of the multiplicity of
particles. Efficiencies between 50% and 90% to single relativistic particles
are reached, and up to 100% in presence of a large number of particles. Time
resolutions between 20ps and 30ps are obtained.Comment: 20 pages, 9 figures. Paper submitted to NIM
Performance of a Tungsten-Cerium Fluoride Sampling Calorimeter in High-Energy Electron Beam Tests
A prototype for a sampling calorimeter made out of cerium fluoride crystals
interleaved with tungsten plates, and read out by wavelength-shifting fibres,
has been exposed to beams of electrons with energies between 20 and 150 GeV,
produced by the CERN Super Proton Synchrotron accelerator complex. The
performance of the prototype is presented and compared to that of a Geant4
simulation of the apparatus. Particular emphasis is given to the response
uniformity across the channel front face, and to the prototype's energy
resolution.Comment: 6 pages, 6 figures, Submitted to NIM
Characterization of a detector for β− radio-guided surgery
This paper reports a new device for the radio-guided surgery technique exploiting β− emitters. A specific intraoperative β− detecting probe based on a low-density organic crystal, the diphenylbutadiene-doped para-therphenyl, coupled by optical fibres to a photomultiplier, was developed. A portable readout electronics was designed to provide the surgeons with multi real-time feedback. The
aspects related to the applicability of the device, in particular the perception of the spatial resolution of the probe and the comprehension time necessary to the operator
to interpret the system response were investigated. Preliminary promising results support the possibility of using this innovative probe in cancer surgery
Secondary radiation measurements for charged particle therapy monitoring: fragmentation of therapeutic He, C and O ion beams impinging on a PMMA target
In Charged Particle Therapy (CPT), besides protons, there has been recently a growing interest in 4He, 12C and 16O beams. The secondary radiation produced in the interaction of those beams with a patient could be potentially used for on‐line monitoring of range uncertainties in order to fully exploit the advantages of those light ions resulting from increased Radio Biological Effectiveness, reduced multiple scattering and Oxygen Enhancement Ratio. The study and precise characterization of secondary radiation (beta+, prompt gamma, charged fragments) is the cornerstone of any R&D activity aiming for online monitoring development and purpose of the analysis presented here
Secondary radiation measurements for charged particle therapy monitoring: fragmentation of therapeutic He, C and O ion beams impinging on a PMMA target
In Charged Particle Therapy (CPT), besides protons, there has been recently a growing interest in 4He, 12C and 16O beams. The secondary radiation produced in the interaction of those beams with a patient could be potentially used for on‐line monitoring of range uncertainties in order to fully exploit the advantages of those light ions resulting from increased Radio Biological Effectiveness, reduced multiple scattering and Oxygen Enhancement Ratio. The study and precise characterization of secondary radiation (beta+, prompt gamma, charged fragments) is the cornerstone of any R&D activity aiming for online monitoring development and purpose of the analysis presented here
Radiation hardness qualification of PbWO4 scintillation crystals for the CMS Electromagnetic Calorimeter
This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2010 IOPEnsuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered
The CMS ECAL Barrel HV system
The CMS electromagnetic calorimeter (ECAL) comprises 75848 scintillating lead tungstate crystals. 61200 crystals are contained in the ECAL Barrel section and are read out by avalanche photodiode (APD) with internal gain of about 50. This gain is achieved with a high voltage (HV) of about 400 Volts. The gain stability requirement implies a supply voltage stable to within 0.01%. We describe our experience with the installed Barrel HV power supply system, which has been used for data taking since 2008
Search for Branons at LEP
We search, in the context of extra-dimension scenarios, for the possible
existence of brane fluctuations, called branons. Events with a single photon or
a single Z-boson and missing energy and momentum collected with the L3 detector
in e^+ e^- collisions at centre-of-mass energies sqrt{s}=189-209$ GeV are
analysed. No excess over the Standard Model expectations is found and a lower
limit at 95% confidence level of 103 GeV is derived for the mass of branons,
for a scenario with small brane tensions. Alternatively, under the assumption
of a light branon, brane tensions below 180 GeV are excluded
- …