6 research outputs found

    Comparative study of the corrosion behavior of peripheral stents in an accelerated corrosion model: experimental in vitro study of 28 metallic vascular endoprostheses

    Get PDF
    PURPOSEClinical cases of stent-fractures show that corrosion behavior might play a role in these fractures. Implanted in vivo, especially in combination with other implanted foreign materials, these metallic products are exposed to special conditions, which can cause a process of corrosion. Here, we aimed to test the corrosion potential of stents made of different materials in an in vitro setting.METHODSA total of 28 peripheral stents of different materials (nitinol, cobalt-chromium-nickel, tantalum, V4A) and surface treatments (electropolish, mechanical polish, no polish) were tested in vitro. Corrosion was accelerated by applying a constant voltage of 3.5 V and amperage of 1.16 mA in 0.9% NaCl.RESULTSNitinol stents showed the lowest susceptibility to corrosion and the longest period without damage. The Memotherm II® (BARD Angiomed®) was the only stent that showed neither macroscopic nor microscopic damages. The worst performing material was cobalt-chromium-nickel, which showed corrosion damages about ten times earlier compared to nitinol. Considering the reasons for termination of the test, nitinol stents primarily showed length deficits, while V4A and tantalum stents showed fractures. Cobalt-chromium-nickel stents had multiple fractures or a complete lysis in equal proportions. When placed in direct contact, nitinol stents showed best corrosion resistance, regardless of what material they were combined with. In terms of polishing treatments, electropolished stents performed the best, mechanical-polished stents and those without polishing treatment followed.CONCLUSIONThe analysis of corrosion behavior may be useful to select the right stent fulfilling the individual needs of the patient within a large number of different stents

    Structured reporting of x-rays for atraumatic shoulder pain: advantages over free text?

    Get PDF
    Background: To analyse structured and free text reports of shoulder X-ray examinations evaluating the quality of reports and potential contributions to clinical decision-making. Methods: We acquired both standard free text and structured reports of 31 patients with a painful shoulder without history of previous trauma who received X-ray exams. A template was created for the structured report based on the template ID 0000154 (Shoulder X-ray) from radreportorg using online software with clickable decision trees with concomitant generation of structured semantic reports. All reports were evaluated regarding overall quality and key features: content, information extraction and clinical relevance. Results: Two experienced orthopaedic surgeons reviewed and rated structured and free text reports of 31 patients independently. The structured reports achieved significantly higher median ratings in all key features evaluated (P< 0.001), including facilitation of information extraction (P< 0.001) and better contribution to subsequent clinical decision-making (P<0.001). The overall quality of structured reports was significantly higher than in free text report (P< 0.001). Conclusions: A comprehensive structured template may be a useful tool to assist in clinical decision-making and is, thus, recommended for the reporting of degenerative changes regarding X-ray examinations of the shoulder

    Outcome and Safety after 103 Radioembolizations with Yttrium-90 Resin Microspheres in 73 Patients with Unresectable Intrahepatic Cholangiocarcinoma—An Evaluation of Predictors

    No full text
    Trans-arterial radioembolization (TARE) is increasingly evaluated for unresectable intrahepatic cholangiocarcinoma (ICC). Not all ICC patients benefit equally well from TARE. Therefore, we sought to evaluate variables predicting progression-free survival (PFS) and overall survival (OS). Patients with non-resectable ICC underwent TARE and were treated with 90Y resin microspheres. Baseline characteristics, biochemical/clinical toxicities, and response were examined for impact on PFS and OS. A total of 103 treatments were administered to 73 patients without major complications or toxicity. Mean OS was 18.9 months (95% confidence intervals (CI); 13.9–23.9 months). Mean and median PFS were 10.1 months (95% CI; 7.9–12.2) and 6.4 months (95% CI; 5.20–7.61), respectively. Median OS and PFS were significantly prolonged in patients with baseline cholinesterase (CHE) ≥ 4.62 kU/L (OS: 14.0 vs. 5.5 months; PFS: 6.9 vs. 3.2 months; p &lt; 0.001). Patients with a tumor burden ≤ 25% had a significantly longer OS (15.2 vs. 6.6 months; p = 0.036). Median PFS was significantly longer for patients with multiple TARE cycles (24.4 vs. 5.8 months; p = 0.04). TARE is a considerable and safe option for unresectable ICC. CA-19-9, CHE, and tumor burden have predictive value for survival in patients treated with TARE. Multiple TARE treatments might further improve survival; this has to be confirmed by further studies

    Computed Tomography of the Head : A Systematic Review on Acquisition and Reconstruction Techniques to Reduce Radiation Dose.

    Get PDF
    In 1971, the first computed tomography (CT) scan was performed on a patient's brain. Clinical CT systems were introduced in 1974 and dedicated to head imaging only. New technological developments, broader availability, and the clinical success of CT led to a steady growth in examination numbers. Most frequent indications for non-contrast CT (NCCT) of the head include the assessment of ischemia and stroke, intracranial hemorrhage and trauma, while CT angiography (CTA) has become the standard for first-line cerebrovascular evaluation; however, resulting improvements in patient management and clinical outcomes come at the cost of radiation exposure, increasing the risk for secondary morbidity. Therefore, radiation dose optimization should always be part of technical advancements in CT imaging but how can the dose be optimized? What dose reduction can be achieved without compromising diagnostic value, and what is the potential of the upcoming technologies artificial intelligence and photon counting CT? In this article, we look for answers to these questions by reviewing dose reduction techniques with respect to the major clinical indications of NCCT and CTA of the head, including a brief perspective on what to expect from current and future developments in CT technology with respect to radiation dose optimization

    Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies

    No full text
    Abstract This study aimed to systematically evaluate the impact of dose reduction on image quality and confidence for intervention planning and guidance regarding computed tomography (CT)-based intervertebral disc and vertebral body biopsies. We retrospectively analyzed 96 patients who underwent multi-detector CT (MDCT) acquired for the purpose of biopsies, which were either derived from scanning with standard dose (SD) or low dose (LD; using tube current reduction). The SD cases were matched to LD cases considering sex, age, level of biopsy, presence of spinal instrumentation, and body diameter. All images for planning (reconstruction: “IMR1”) and periprocedural guidance (reconstruction: “iDose4”) were evaluated by two readers (R1 and R2) using Likert scales. Image noise was measured using attenuation values of paraspinal muscle tissue. The dose length product (DLP) was statistically significantly lower for LD scans regarding the planning scans (SD: 13.8 ± 8.2 mGy*cm, LD: 8.1 ± 4.4 mGy*cm, p  0.05). Image noise was similar between SD and LD scans performed for planning of the interventional procedures (SD: 14.62 ± 2.83 HU vs. LD: 15.45 ± 3.22 HU, p = 0.24). Use of a LD protocol for MDCT-guided biopsies along the spine is a practical alternative, maintaining overall image quality and confidence. Increasing availability of model-based iterative reconstruction in clinical routine may facilitate further radiation dose reductions
    corecore