2 research outputs found

    The Influence of Fat Suppression Technique on Diffusion-weighted (DW) MRI in Lung Cancer

    Get PDF
    Purpose: To qualitatively and quantitatively investigate the effect of common vendor-related sequence variations in fat suppression techniques on the diagnostic performance of free-breathing DW protocols for lung imaging.Methods: 8 patients with malignant lung lesions were scanned in free breathing using two diffusion-weighted (DW) protocols with different fat suppression techniques: DWA used short-tau inversion recovery (STIR), and DWB used Spectral Adiabatic Inversion Recovery (SPAIR). Both techniques were obtained at two time points, between 1 hour and 1 week apart. Image quality was assessed using a 5-point scoring system. The number of lesions visible within lung, mediastinum and at thoracic inlet on the DW (b=800 s/mm2) images was compared. Signal-to-noise ratios (SNR) were calculated for lesions and para-spinal muscle. Repeatability of ADC values of the lesions was estimated for both protocols together and separately.Results: There was a signal void at the thoracic inlet in all patients with DWB but not with DWA. DWA images were rated significantly better than DWB images overall quality domains. (Cohens κ = 1). Although 8 more upper mediastinal/thoracic inlet lymph nodes were detected with DWA than DWB, this did not reach statistical significance (p = 0.23). Tumour ADC values were not significantly different between protocols (p=0.93), their ADC reproducibility was satisfactory (CoV=7.7%) and repeatability of each protocol separately was comparable (CoVDWA=3.7% (95% CI 2.5 7.1%) and CoVDWB=4.6% (95% CI 3.18.8%)).Conclusion: In a free-breathing DW-MRI protocol for lung, STIR fat suppression produced images of better diagnostic quality than SPAIR, while maintaining comparable SNR and providing repeatable quantitative ADC acceptable for use in a multicentre trial setting

    Repertorium für die Pharmacie 81. 1843 oder 2. Reihe 31. Band

    Get PDF
    Purpose To determine the test-retest repeatability of Apparent Diffusion Coefficient (ADC) measurements across institutions and MRI vendors, plus investigate the effect of post-processing methodology on measurement precision.Methods Thirty malignant lung lesions >2 cm in size (23 patients) were scanned on two occasions, using echo-planar-Diffusion-Weighted (DW)-MRI to derive whole-tumour ADC (b = 100, 500 and 800smm-2). Scanning was performed at 4 institutions (3 MRI vendors). Whole-tumour volumes-of-interest were copied from first visit onto second visit images and from one post-processing platform to an open-source platform, to assess ADC repeatability and cross-platform reproducibility.Results Whole-tumour ADC values ranged from 0.66-1.94x10-3mm2s-1 (mean = 1.14). Within-patient coefficient-of-variation (wCV) was 7.1% (95% CI 5.7-9.6%), limits-of-agreement (LoA) -18.0 to 21.9%. Lesions >3 cm had improved repeatability: wCV 3.9% (95% CI 2.9-5.9%); and LoA -10.2 to 11.4%. Variability for lesions 2 = 0.99; CoV 2.8% (95% CI 2.3-3.4%); and LoA -7.4 to 8.0%.Conclusion A free-breathing DW-MRI protocol for imaging malignant lung tumours achieved satisfactory within-patient repeatability and was robust to changes in post-processing software, justifying its use in multi-centre trials. For response evaluation in individual patients, a change in ADC >21.9% will reflect treatment-related change.Key points • In lung cancer, free-breathing DWI-MRI produces acceptable images with evaluable ADC measurement. • ADC repeatability coefficient-of-variation is 7.1% for lung tumours >2 cm. • ADC repeatability coefficient-of-variation is 3.9% for lung tumours >3 cm. • ADC measurement precision is unaffected by the post-processing software used. • In multicentre trials, 22% increase in ADC indicates positive treatment response
    corecore