36 research outputs found

    Perceptions on site-specific advanced practice roles for radiation therapists in Singapore : a single centre study

    Get PDF
    Perception of the radiation oncologists (ROs) and radiation therapists (RTTs) on site-specific advanced practice (SSAP) roles for RTTs, the establishment of SSAP in radiotherapy and the possible implication on current services in Singapore were assessed. Opinions of ROs and RTTs on management support, driving forces, restraints and implication upon successful establishment of SSAP were obtained. Main findings include strong RO’s support for SSAP development and RTTs' requisition for fair opportunities on role development. Other potential benefits include RTTs' career advancement, job satisfaction and retention. Enhancement of inter-professional relationship, service quality and patient satisfaction is anticipated with greater communication and collaboration

    Prevalence, associated factors and outcomes of pressure injuries in adult intensive care unit patients: the DecubICUs study

    Get PDF
    Funder: European Society of Intensive Care Medicine; doi: http://dx.doi.org/10.13039/501100013347Funder: Flemish Society for Critical Care NursesAbstract: Purpose: Intensive care unit (ICU) patients are particularly susceptible to developing pressure injuries. Epidemiologic data is however unavailable. We aimed to provide an international picture of the extent of pressure injuries and factors associated with ICU-acquired pressure injuries in adult ICU patients. Methods: International 1-day point-prevalence study; follow-up for outcome assessment until hospital discharge (maximum 12 weeks). Factors associated with ICU-acquired pressure injury and hospital mortality were assessed by generalised linear mixed-effects regression analysis. Results: Data from 13,254 patients in 1117 ICUs (90 countries) revealed 6747 pressure injuries; 3997 (59.2%) were ICU-acquired. Overall prevalence was 26.6% (95% confidence interval [CI] 25.9–27.3). ICU-acquired prevalence was 16.2% (95% CI 15.6–16.8). Sacrum (37%) and heels (19.5%) were most affected. Factors independently associated with ICU-acquired pressure injuries were older age, male sex, being underweight, emergency surgery, higher Simplified Acute Physiology Score II, Braden score 3 days, comorbidities (chronic obstructive pulmonary disease, immunodeficiency), organ support (renal replacement, mechanical ventilation on ICU admission), and being in a low or lower-middle income-economy. Gradually increasing associations with mortality were identified for increasing severity of pressure injury: stage I (odds ratio [OR] 1.5; 95% CI 1.2–1.8), stage II (OR 1.6; 95% CI 1.4–1.9), and stage III or worse (OR 2.8; 95% CI 2.3–3.3). Conclusion: Pressure injuries are common in adult ICU patients. ICU-acquired pressure injuries are associated with mainly intrinsic factors and mortality. Optimal care standards, increased awareness, appropriate resource allocation, and further research into optimal prevention are pivotal to tackle this important patient safety threat

    Evaluation of inter- and intra-observer variations in prostate gland delineation using CT-alone versus CT/TPUS

    Get PDF
    Background: This study aims to explore the role of four-dimensional (4D) transperineal ultrasound (TPUS) in the contouring of prostate gland with planning computed tomography (CT) images, in the absence of magnetic resonance imaging (MRI). Materials and methods: Five radiation oncologists (ROs) performed two rounds of prostate gland contouring (single-blinded) on CT-alone and CT/TPUS datasets obtained from 10 patients who underwent TPUS-guided external beam radiotherapy. Parameters include prostate volume, DICE similarity coefficient (DSC) and centroid position. Wilcoxon signed-rank test assessed the significance of inter-modality differences, and the intraclass correlation coefficient (ICC) reflected inter- and intra-observer reliability of parameters. Results: Inter-modality analysis revealed high agreement (based on DSC and centroid position) of prostate gland contours between CT-alone and CT/TPUS. Statistical significant difference was observed in the superior-inferior direction of the prostate centroid position (p = 0.011). All modalities yielded excellent inter-observer reliability of delineated prostate volume with ICC > 0.9, mean DSC > 0.8 and centroid position: CT-alone (ICC = 1.000) and CT/TPUS (ICC = 0.999) left-right (L/R); CT-alone (ICC = 0.999) and CT/TPUS (ICC = 0.998) anterior-posterior (A/P); CT-alone (ICC = 0.999) and CT/TPUS (ICC = 1.000) superior-inferior (S/I). Similarly, all modalities yielded excellent intra-observer reliability of delineated prostate volume, ICC > 0.9 and mean DSC > 0.8. Lastly, intra-observer reliability was excellent on both imaging modalities for the prostate centroid position, ICC > 0.9. Conclusion: TPUS does not add significantly to the amount of anatomical information provided by CT images. However, TPUS can supplement planning CT to achieve a higher positional accuracy in the S/I direction if access to CT/MRI fusion is limited

    Analysis of intra-fraction prostate motion and derivation of duration-dependent margins for radiotherapy using real-time 4D ultrasound

    No full text
    Background and purpose: During radiotherapy, prostate motion changes over time. Quantifying and accounting for this motion is essential. This study aimed to assess intra-fraction prostate motion and derive duration-dependent planning margins for two treatment techniques. Material and methods: A four-dimension (4D) transperineal ultrasound Clarity® system was used to track prostate motion. We analysed 1913 fractions from 60 patients undergoing volumetric-modulated arc therapy (VMAT) to the prostate. The mean VMAT treatment duration was 3.4 min. Extended monitoring was conducted weekly to simulate motion during intensity-modulated radiation therapy (IMRT) treatment (an additional seven minutes). A motion-time trend analysis was conducted and the mean intra-fraction motion between VMAT and IMRT treatments compared. Duration-dependent margins were calculated and anisotropic margins for VMAT and IMRT treatments were derived. Results: There were statistically significant differences in the mean intra-fraction motion between VMAT and the simulated IMRT duration in the inferior (0.1 mm versus 0.3 mm) and posterior (−0.2 versus −0.4 mm) directions respectively (p ≪ 0.01). An intra-fraction motion trend inferiorly and posteriorly was observed. The recommended minimum anisotropic margins are 1.7 mm/2.7 mm (superior/inferior); 0.8 mm (left/right), 1.7 mm/2.9 mm (anterior/posterior) for VMAT treatments and 2.9 mm/4.3 mm (superior/inferior), 1.5 mm (left/right), 2.8 mm/4.8 mm (anterior/posterior) for IMRT treatments. Smaller anisotropic margins were required for VMAT compared to IMRT (differences ranging from 1.2 to 1.6 mm superiorly/inferiorly, 0.7 mm laterally and 1.1–1.9 mm anteriorly/posteriorly). Conclusions: VMAT treatment is preferred over IMRT as prostate motion increases with time. Larger margins should be employed in the inferior and posterior directions for both treatment durations. Duration-dependent margins should be applied in the presence of prolonged imaging and verification time. Keywords: Prostate, Intra-fraction movement, 4D Clarity ultrasound system, Real-time tracking, Margin

    Reduction of intra-fraction prostate motion – Determining optimal bladder volume and filling for prostate radiotherapy using daily 4D TPUS and CBCT

    No full text
    Background and purpose: Inconsistent bladder and rectal volumes have been associated with motion uncertainties during prostate radiotherapy. This study investigates the impact of these volumes to determine the optimal bladder volume. Materials and methods: 60 patients from two Asian hospitals were recruited prospectively. 1887 daily cone-beam computed tomography (CBCT) images were analysed. Intra-fraction motion of the prostate was monitored real-time using a four-dimension transperineal ultrasound (4D TPUS) Clarity® system. The impact of planned bladder volume, adequacy of daily bladder filling, and rectum volume on mean intra-fraction motion of the prostate was analysed. Patients’ ability to comply with the full bladder hydration protocol and level of frustration was assessed using a questionaire. Acute side effects were assessed using the Common Terminology Criteria for Adverse Events (CTCAE) version 3.0 and quality of life (QoL) assessed using the International Prostate Symptom Score (IPSS). Results: The mean (SD) bladder and rectum volumes achieved during daily treatment were 139.7 cm3 (82.4 cm3) and 53.3 cm3 (18 cm3) respectively. Mean (SD) percentage change from planned CT volumes in bladder volume was reduced by 8.2% (48.7%) and rectum volume was increased by 12.4% (42.2%). Linear Mixed effect model analysis revealed a reduction in intra-fraction motion in both the Sup/Inf (p = 0.008) and Ant/Post (p = 0.0001) directions when the daily bladder was filled between 82 and 113% (3rd Quartiles) of the planned CT volumes. A reduction in intra-fraction motion of the prostate in the Ant/Post direction (z-plane) (p = 0.03) was observed when the planned bladder volume was greater than 200 ml. Patients complied well with the hydration protocol with minimal frustration (mean (SD) scores of 2.1 (1.4) and 1.8 (1.2) respectively). There was a moderate positive correlation (0.496) between mean bladder volume and IPSS reported post-treatment urinary straining (p = 0.001). Conclusions: A planned bladder volume >200 cm3 and daily filling between 82 and 113%, reduced intra-fraction motion of the prostate. The hydration protocol was well tolerated. Keywords: Prostate radiotherapy, Full bladder hydration protocol, Intra-fraction motion, 4D TPUS clarity, Real-time trackin

    An assessment of the magnitude of intra-fraction movement of head-and-neck IMRT cases and its implication on the action-level of the imaging protocol.

    No full text
    BACKGROUND AND PURPOSE: A planning margin ⩽3mm is employed in some head-and-neck IMRT cases due to the proximity of critical structures. This study aims to explore the need to redefine the action-level in the head-and-neck imaging protocol in consideration of the intra-fraction movement. MATERIAL AND METHODS: This is a local study of 18 patients treated using the same immobilisation system and setup protocol. Post-treatment orthogonal pair of kilovoltage X-ray images was acquired on the first three days of treatment. 106 sets of pre- and post-treatment kV X-ray images acquired over 53 fractions were analysed against the treatment planning DRR for calculation of intra-fraction movement. RESULTS: Individual mean intra-fraction movement in all directions ranged from -1.8 to 1.1mm. Population mean (median) intra-fraction movement in the x-, y-, and z-planes were -0.1mm (0mm), -0.3mm (-0.3mm) and -0.2mm (-0.2mm) respectively. Intra-fraction movement in all three dimensions, x-, y- and z-planes were considered statistically significant (p<0.05). 7 out of 53 fractions (13.2%) were highlighted as the combined magnitude of the intra-fraction motion with the uncorrected pre-treatment setup errors had exceeded the boundaries of given margins. CONCLUSIONS: 3mm-AL was not adequate to account for intra-fraction movement when the CTV-PTV margin was ⩽3mm and should be excluded from the routine imaging protocol and daily image-guided radiotherapy should be employed. Adjusting the action-level to 2mm would allow a more confident approach in delivery of the prescribed dose in head-and-neck IMRT cases

    A Deep Learning-Based Automated CT Segmentation of Prostate Cancer Anatomy for Radiation Therapy Planning-A Retrospective Multicenter Study

    No full text
    A commercial deep learning (DL)-based automated segmentation tool (AST) for computed tomography (CT) is evaluated for accuracy and efficiency gain within prostate cancer patients. Thirty patients from six clinics were reviewed with manual- (MC), automated- (AC) and automated and edited (AEC) contouring methods. In the AEC group, created contours (prostate, seminal vesicles, bladder, rectum, femoral heads and penile bulb) were edited, whereas the MC group included empty datasets for MC. In one clinic, lymph node CTV delineations were evaluated for interobserver variability. Compared to MC, the mean time saved using the AST was 12 min for the whole data set (46%) and 12 min for the lymph node CTV (60%), respectively. The delineation consistency between MC and AEC groups according to the Dice similarity coefficient (DSC) improved from 0.78 to 0.94 for the whole data set and from 0.76 to 0.91 for the lymph nodes. The mean DSCs between MC and AC for all six clinics were 0.82 for prostate, 0.72 for seminal vesicles, 0.93 for bladder, 0.84 for rectum, 0.69 for femoral heads and 0.51 for penile bulb. This study proves that using a general DL-based AST for CT images saves time and improves consistency
    corecore