1,374 research outputs found
The role of magnetoplasmons in Casimir force calculations
In this paper we review the role of magneto plasmon polaritons in the Casimir
force calculations. By applying an external constant magnetic field a strong
optical anisotropy is induced on two parallel slabs reducing the reflectivity
and thus the Casimir force. As the external magnetic field increases, the
Casimir force decreases. Thus, with an an external magnetic field the Casimir
force can be controlled.The calculations are done in the Voigt configuration
where the magnetic field is parallel to the slabs. In this configuration the
reflection coefficients for TE and TM modes do not show mode conversion.Comment: contribution to QFEXT09, Norman, Oklahoma 200
Analysis of Indoor Radon Distribution Within a Room By Means of Computational Fluid Dynamics (CFD) Simulation
Radon gas is recognized by international organizations such as the United States Environmental Protection Agency (US-EPA) as the main contributor of radiation environmental to which human beings are exposed. Therefore, the evaluation of indoor radon concentration is a matter of public interest. The emanation and the income of the gas inside a room will generate a negative impact on the quality of the air when the place is not properly ventilated. Understanding how this gas will be distributed inside the room will allow to predict the spatial and temporal variations of radon levels and identify these parameters will provide important information that researchers can be used for calculate radiation dose exposure. Consequently, this studies can prevent a health risk for the people that live or work within the room. Currently, several researchers use the technique called Computational Fluid Dynamics (CFD) to simulate the distribution of gas radon, making use of the various commercial programs that exist in the market. In this work, three simulations were developed in rooms that have a similar geometry but different dimensions, in order to observe how the gas is distributed inside a closed space and to analyze how this distribution varies when the volume of the place is increased. The results show that as the volume of the site increases the radon is mitigated more rapidly and therefore has lower levels of concentration of this gas, as long as the level of radon emanation is kept constant
Van der Waals torque induced by external magnetic fields
We present a method for inducing and controlling van der Waals torques
between two parallel slabs using a constant magnetic field. The torque is
calculated using the Barash theory of dispersive torques. In III-IV
semiconductors such as , the effect of an external magnetic field is to
induce an optical anisotropy, in an otherwise isotropic material, that will in
turn induce a torque.
The calculations of the torque are done in the Voigt configuration, with the
magnetic field parallel to the surface of the slabs. As a case study we
consider a slab made of calcite and a second slab made of . In the
absence of magnetic field there is no torque. As the magnetic field increases,
the optical anisotropy of increases and the torque becomes different
from zero, increasing with the magnetic field. The resulting torque is of the
same order of magnitude as that calculated using permanent anisotropic
materials when the magnetic fields is close to 1 T.Comment: to appear in Journal of Applied Physic
Pull-in control due to Casimir forces using external magnetic fields
We present a theoretical calculation of the pull-in control in capacitive
micro switches actuated by Casimir forces, using external magnetic fields. The
external magnetic fields induces an optical anisotropy due to the excitation of
magneto plasmons, that reduces the Casimir force. The calculations are
performed in the Voigt configuration, and the results show that as the magnetic
field increases the system becomes more stable. The detachment length for a
cantilever is also calculated for a cantilever, showing that it increases with
increasing magnetic field. At the pull-in separation, the stiffness of the
system decreases with increasing magnetic field.Comment: accepted for publication in App. Phys. Let
Optimization of the Position of the CR-39 Polycarbonate Sheet Inside the Solid State Track Detector “Measuring Device” Through Computational Fluid Dynamics Technique
The “measuring device” is one of the most reliable, efficient and economic indoor radon dosimeters that exist. This device was developed by the Proyecto de Aplicaciones de la Dosimetría (PAD) at the Physics Institute of UNAM (IF-UNAM) and consists of a transparent rigid plastic cup, a CR-39 polycarbonate sheet and a standard size metal clip that is used to hold the polycarbonate in the center of the cup. The cup is wrapped and covered with a low-density polyurethane protector in order to prevent the detector from being irradiated by ionizing particles found in the environment. In this work, an analysis was carried out that allowed to understand how the radon concentration on the polycarbonate sheet varies when its height is changed with respect to the base of the plastic cup, in order to understand what position increase the probability of interaction between radon and the surface of the detector. For the development of this work, four computational simulations were performed with the technique called Computational Fluid Dynamics (CFD). The results shows that as the CR-39 is positioned more closed to the base of the cup, the probability of interaction of the radon and the detector increase. Based on these results it is concluded that, when there is a limit in the time in which a measuring device can be placed in the zone where it is desired to quantify indoor radon, it is recommended to collocated the CR-39 at 1 cm with respect to the base of the cup
A Modeling Approach for Measuring the Performance of a Human-AI Collaborative Process
Despite the unabated growth of algorithmic decision-making in organizations, there is a growing consensus that numerous situations will continue to require humans in the loop. However, the blending of a formal machine and bounded human rationality also amplifies the risk of what is known as local rationality. Therefore, it is crucial, especially in a data-abundant environment that characterizes algorithmic decision-making, to devise means to assess performance holistically. In this paper, we propose a simulation-based model to address the current lack of research on quantifying algorithmic interventions in a broader organizational context. Our approach allows the combining of causal modeling and data science algorithms to represent decision settings involving a mix of machine and human rationality to measure performance. As a testbed, we consider the case of a fictitious company trying to improve its forecasting process with the help of a machine learning approach. The example demonstrates that a myopic assessment obscures problems that only a broader framing reveals. It highlights the value of a systems view since the effects of the interplay between human and algorithmic decisions can be largely unintuitive. Such a simulation-based approach can be an effective tool in efforts to delineate roles for humans and algorithms in hybrid contexts
Analysis and characterization of neutron scattering of a Linear Accelerator (LINAC) on medical applications.
In several theoretical and experimental studies, the topic of the undesirable generation of photoneutrons in rooms where a linear accelerator (LINAC) operates has been discussed. When energies above 10 MeV are used to produce X-rays and give radiotherapy treatment to patients resulting in additional radiation to patients. Accordingly, an analysis and characterization of the neutron scattering distribution on different zones in a treatment room contributes to evaluate the radiological health risk to patients, technical and other workers involved in treatment. For the evaluation, a device developed at the PAD-IFUNAM formed by a CR-39 detector enclosed by two 3mm thick acrylic plates was employed. To avoid environmental contamination, the CR-39 and the acrylics plates are enclosed in a round plastic box. Sixteen of these devices were settled in different places inside the treatment room, where a linear accelerator is used. The results show a significant concentration of neutron scattering in areas near the head of irradiation. The recommendation will be to evaluate the neutron scattering concentration in all rooms that’s operates a LINAC in order to verify the radiological health risk and to mitigate the neutron scattering when concentration levels are to high like those in our case, in order to avoid unnecessary exposition to patients and personnel in general
The Indoor Radon Concentration within the Tunnels of the Cholula Pyramid Through a Nuclear Tracks Methodology
Global organizations, including the World Health Organization (WHO), the Environmental Protection Agency of the United States (US-EPA) and the European Atomic Energy Community (EURATOM) recognize that radon gas as one of the main contributors to environmental radiation exposure for humans. Accordingly, a study and analysis of the indoors radon concentrate in the Cholula Pyramid contributes to understand the Radon dynamic inside of the Pyramid tunnels and to evaluate the radiological health risk to visitors, archaeologists, anthropologists and persons who spend extended periods inside the Pyramid. In this paper, the radon measurements along the Pyramid tunnels are presented. The Nuclear Track Methodology (NTM) was chosen for the measurements, using a close end-cup device developed at the Dosimetry Application Project (DAP) of the Physics Institute UNAM, following very well established protocols for the chemical etching and reading with the Counting Analysis Digital Imaging System (CADIS). The Cholula Pyramid consists of eight stages of constructions, each built in different periods of time. Cholula Pyramid is recognized as the pyramid with the largest base in the World, with 400 meters per side and 65 meters high. The tunnels of the pyramid were built in 1931 by architect Ignacio Marquina, with the aim of exploring and studying the structure. The results show an important indoor radon concentration in the measured tunnels, several times higher than levels recommended by United States Environmental Protection Agency (US-EPA). The recommendation will be to mitigate the radon concentration levels, in order to avoid unnecessary exposition to the people
- …