19,826 research outputs found

    A NuSTAR observation of the fast symbiotic nova V745 Sco in outburst

    Get PDF
    The fast recurrent nova V745 Sco was observed in the 3-79 keV X-rays band with NuSTAR 10 days after the optical discovery. The measured X-ray emission is consistent with a collisionally ionized optically thin plasma at temperature of about 2.7 keV. A prominent iron line observed at 6.7 keV does not require enhanced iron in the ejecta. We attribute the X-ray flux to shocked circumstellar material. No X-ray emission was observed at energies above 20 keV, and the flux in the 3-20 keV range was about 1.6 ×\times 10−11^{-11} erg cm−2^{-2} s−1^{-1}. The emission measure indicates an average electron density of order of 107^7 cm−3^{-3}. The X-ray flux in the 0.3-10 keV band almost simultaneously measured with Swift was about 40 times larger, mainly due to the luminous central supersoft source emitting at energy below 1 keV. The fact that the NuSTAR spectrum cannot be fitted with a power law, and the lack of hard X-ray emission, allow us to rule out Comptonized gamma rays, and to place an upper limit of the order of 10−11^{-11} erg cm−2^{-2} s−1^{-1} on the gamma-ray flux of the nova on the tenth day of the outburst.Comment: in press in Monthly Notices of the Royal Astronomical Society, 201

    A design study of hydrazine and biowaste resistojets

    Get PDF
    A generalized modeling program was adapted in BASIC on a personal computer to compare the performance of four types of biowaste resistojets and two types of hydrazine augmenters. Analyzed biowaste design types were: (1) an electrically conductive ceramic heater-exchanger of zirconia; (2) a truss heater of platinum in cross flow; (3) an immersed bicoiled tubular heater-exchanger; and (4) a nonexposed, refractory metal, radiant heater in a central cavity within a heat exchanger case. Concepts 2 and 3 are designed to have an efficient, stainless steel outer pressure case. The hydrazine design types are: (5) an immersed bicoil heater exchanger and (6) a nonexposed radiant heater now with a refractory metal case. The ceramic biowaste resistojet has the highest specific impulse growth potential at 2000 K of 192.5 (CO2) and 269 s (H2O). The bicoil produces the highest augmenter temperature of 1994 K for a 2073 K heater giving 317 s at .73 overall efficiency. Detailed temperature profiles of each of the designs are shown. The scaled layout drawings of each are presented with recommended materials and fabrication methods

    Resolving the large scale spectral variability of the luminous Seyfert 1 galaxy 1H 0419-577: Evidence for a new emission component and absorption by cold dense matter

    Full text link
    An XMM-Newton observation of the luminous Seyfert 1 galaxy 1H 0419-577 in September 2002, when the source was in an extreme low-flux state, found a very hard X-ray spectrum at 1-10 keV with a strong soft excess below ~1 keV. Comparison with an earlier XMM-Newton observation when 1H 0419-577 was `X-ray bright' indicated the dominant spectral variability was due to a steep power law or cool Comptonised thermal emission. Four further XMM-Newton observations, with 1H 0419-577 in intermediate flux states, now support that conclusion, while we also find the variable emission component in intermediate state difference spectra to be strongly modified by absorption in low ionisation matter. The variable `soft excess' then appears to be an artefact of absorption of the underlying continuum while the `core' soft emission can be attributed to recombination in an extended region of more highly ionised gas. We note the wider implications of finding substantial cold dense matter overlying (or embedded in) the X-ray continuum source in a luminous Seyfert 1 galaxy.Comment: 34 pages, 15 figures, submitted to Ap

    An XMM-Newton observation of the Narrow Line Seyfert 1 Galaxy, Markarian 896

    Get PDF
    XMM-Newton observations of the NLS1 Markarian 896 are presented. Over the 2-10 keV band, an iron emission line, close to 6.4 keV, is seen. The line is just resolved and has an equivalent width of ~170 eV. The broad-band spectrum is well modelled by a power law slope of gamma ~ 2.03, together with two blackbody components to fit the soft X-ray excess. Using a more physical two-temperature Comptonisation model, a good fit is obtained for an input photon distribution of kT ~ 60eV and Comptonising electron temperatures of ~0.3 and 200 keV. The soft excess cannot be explained purely through the reprocessing of a hard X-ray continuum by an ionised disc reflector.Comment: 6 pages, 4 figures, accepted by MNRA

    Freak observers and the measure of the multiverse

    Get PDF
    I suggest that the factor pjp_j in the pocket-based measure of the multiverse, Pj=pjfjP_j=p_j f_j, should be interpreted as accounting for equilibrium de Sitter vacuum fluctuations, while the selection factor fjf_j accounts for the number of observers that were formed due to non-equilibrium processes resulting from such fluctuations. I show that this formulation does not suffer from the problem of freak observers (also known as Boltzmann brains).Comment: 6 pages, no figures; references adde

    A search for thermal X-ray signatures in Gamma-Ray Bursts I: Swift bursts with optical supernovae

    Full text link
    The X-ray spectra of Gamma-Ray Bursts can generally be described by an absorbed power law. The landmark discovery of thermal X-ray emission in addition to the power law in the unusual GRB 060218, followed by a similar discovery in GRB 100316D, showed that during the first thousand seconds after trigger the soft X-ray spectra can be complex. Both the origin and prevalence of such spectral components still evade understanding, particularly after the discovery of thermal X-ray emission in the classical GRB 090618. Possibly most importantly, these three objects are all associated with optical supernovae, begging the question of whether the thermal X-ray components could be a result of the GRB-SN connection, possibly in the shock breakout. We therefore performed a search for blackbody components in the early Swift X-ray spectra of 11 GRBs that have or may have associated optical supernovae, accurately recovering the thermal components reported in the literature for GRBs 060218, 090618 and 100316D. We present the discovery of a cooling blackbody in GRB 101219B/SN2010ma, and in four further GRB-SNe we find an improvement in the fit with a blackbody which we deem possible blackbody candidates due to case-specific caveats. All the possible new blackbody components we report lie at the high end of the luminosity and radius distribution. GRB 101219B appears to bridge the gap between the low-luminosity and the classical GRB-SNe with thermal emission, and following the blackbody evolution we derive an expansion velocity for this source of order 0.4c. We discuss potential origins for the thermal X-ray emission in our sample, including a cocoon model which we find can accommodate the more extreme physical parameters implied by many of our model fits.Comment: 16 pages, 6 figures, accepted for MNRA
    • …
    corecore