19,826 research outputs found
A NuSTAR observation of the fast symbiotic nova V745 Sco in outburst
The fast recurrent nova V745 Sco was observed in the 3-79 keV X-rays band
with NuSTAR 10 days after the optical discovery. The measured X-ray emission is
consistent with a collisionally ionized optically thin plasma at temperature of
about 2.7 keV. A prominent iron line observed at 6.7 keV does not require
enhanced iron in the ejecta. We attribute the X-ray flux to shocked
circumstellar material. No X-ray emission was observed at energies above 20
keV, and the flux in the 3-20 keV range was about 1.6 10 erg
cm s. The emission measure indicates an average electron density
of order of 10 cm.
The X-ray flux in the 0.3-10 keV band almost simultaneously measured with
Swift was about 40 times larger, mainly due to the luminous central supersoft
source emitting at energy below 1 keV. The fact that the NuSTAR spectrum cannot
be fitted with a power law, and the lack of hard X-ray emission, allow us to
rule out Comptonized gamma rays, and to place an upper limit of the order of
10 erg cm s on the gamma-ray flux of the nova on the
tenth day of the outburst.Comment: in press in Monthly Notices of the Royal Astronomical Society, 201
A design study of hydrazine and biowaste resistojets
A generalized modeling program was adapted in BASIC on a personal computer to compare the performance of four types of biowaste resistojets and two types of hydrazine augmenters. Analyzed biowaste design types were: (1) an electrically conductive ceramic heater-exchanger of zirconia; (2) a truss heater of platinum in cross flow; (3) an immersed bicoiled tubular heater-exchanger; and (4) a nonexposed, refractory metal, radiant heater in a central cavity within a heat exchanger case. Concepts 2 and 3 are designed to have an efficient, stainless steel outer pressure case. The hydrazine design types are: (5) an immersed bicoil heater exchanger and (6) a nonexposed radiant heater now with a refractory metal case. The ceramic biowaste resistojet has the highest specific impulse growth potential at 2000 K of 192.5 (CO2) and 269 s (H2O). The bicoil produces the highest augmenter temperature of 1994 K for a 2073 K heater giving 317 s at .73 overall efficiency. Detailed temperature profiles of each of the designs are shown. The scaled layout drawings of each are presented with recommended materials and fabrication methods
Resolving the large scale spectral variability of the luminous Seyfert 1 galaxy 1H 0419-577: Evidence for a new emission component and absorption by cold dense matter
An XMM-Newton observation of the luminous Seyfert 1 galaxy 1H 0419-577 in
September 2002, when the source was in an extreme low-flux state, found a very
hard X-ray spectrum at 1-10 keV with a strong soft excess below ~1 keV.
Comparison with an earlier XMM-Newton observation when 1H 0419-577 was `X-ray
bright' indicated the dominant spectral variability was due to a steep power
law or cool Comptonised thermal emission. Four further XMM-Newton observations,
with 1H 0419-577 in intermediate flux states, now support that conclusion,
while we also find the variable emission component in intermediate state
difference spectra to be strongly modified by absorption in low ionisation
matter. The variable `soft excess' then appears to be an artefact of absorption
of the underlying continuum while the `core' soft emission can be attributed to
recombination in an extended region of more highly ionised gas. We note the
wider implications of finding substantial cold dense matter overlying (or
embedded in) the X-ray continuum source in a luminous Seyfert 1 galaxy.Comment: 34 pages, 15 figures, submitted to Ap
An XMM-Newton observation of the Narrow Line Seyfert 1 Galaxy, Markarian 896
XMM-Newton observations of the NLS1 Markarian 896 are presented. Over the
2-10 keV band, an iron emission line, close to 6.4 keV, is seen. The line is
just resolved and has an equivalent width of ~170 eV. The broad-band spectrum
is well modelled by a power law slope of gamma ~ 2.03, together with two
blackbody components to fit the soft X-ray excess. Using a more physical
two-temperature Comptonisation model, a good fit is obtained for an input
photon distribution of kT ~ 60eV and Comptonising electron temperatures of ~0.3
and 200 keV. The soft excess cannot be explained purely through the
reprocessing of a hard X-ray continuum by an ionised disc reflector.Comment: 6 pages, 4 figures, accepted by MNRA
Freak observers and the measure of the multiverse
I suggest that the factor in the pocket-based measure of the
multiverse, , should be interpreted as accounting for equilibrium
de Sitter vacuum fluctuations, while the selection factor accounts for
the number of observers that were formed due to non-equilibrium processes
resulting from such fluctuations. I show that this formulation does not suffer
from the problem of freak observers (also known as Boltzmann brains).Comment: 6 pages, no figures; references adde
A search for thermal X-ray signatures in Gamma-Ray Bursts I: Swift bursts with optical supernovae
The X-ray spectra of Gamma-Ray Bursts can generally be described by an
absorbed power law. The landmark discovery of thermal X-ray emission in
addition to the power law in the unusual GRB 060218, followed by a similar
discovery in GRB 100316D, showed that during the first thousand seconds after
trigger the soft X-ray spectra can be complex. Both the origin and prevalence
of such spectral components still evade understanding, particularly after the
discovery of thermal X-ray emission in the classical GRB 090618. Possibly most
importantly, these three objects are all associated with optical supernovae,
begging the question of whether the thermal X-ray components could be a result
of the GRB-SN connection, possibly in the shock breakout. We therefore
performed a search for blackbody components in the early Swift X-ray spectra of
11 GRBs that have or may have associated optical supernovae, accurately
recovering the thermal components reported in the literature for GRBs 060218,
090618 and 100316D. We present the discovery of a cooling blackbody in GRB
101219B/SN2010ma, and in four further GRB-SNe we find an improvement in the fit
with a blackbody which we deem possible blackbody candidates due to
case-specific caveats. All the possible new blackbody components we report lie
at the high end of the luminosity and radius distribution. GRB 101219B appears
to bridge the gap between the low-luminosity and the classical GRB-SNe with
thermal emission, and following the blackbody evolution we derive an expansion
velocity for this source of order 0.4c. We discuss potential origins for the
thermal X-ray emission in our sample, including a cocoon model which we find
can accommodate the more extreme physical parameters implied by many of our
model fits.Comment: 16 pages, 6 figures, accepted for MNRA
- …