10 research outputs found
Recommended from our members
Intravenous ferric derisomaltose in patients with heart failure and iron deficiency in the UK (IRONMAN): an investigator-initiated, prospective, randomised, open-label, blinded-endpoint trial.
BACKGROUND: For patients with heart failure, reduced left ventricular ejection fraction and iron deficiency, intravenous ferric carboxymaltose administration improves quality of life and exercise capacity in the short-term and reduces hospital admissions for heart failure up to 1 year. We aimed to evaluate the longer-term effects of intravenous ferric derisomaltose on cardiovascular events in patients with heart failure. METHODS: IRONMAN was a prospective, randomised, open-label, blinded-endpoint trial done at 70 hospitals in the UK. Patients aged 18 years or older with heart failure (left ventricular ejection fraction ≤45%) and transferrin saturation less than 20% or serum ferritin less than 100 μg/L were eligible. Participants were randomly assigned (1:1) using a web-based system to intravenous ferric derisomaltose or usual care, stratified by recruitment context and trial site. The trial was open label, with masked adjudication of the outcomes. Intravenous ferric derisomaltose dose was determined by patient bodyweight and haemoglobin concentration. The primary outcome was recurrent hospital admissions for heart failure and cardiovascular death, assessed in all validly randomly assigned patients. Safety was assessed in all patients assigned to ferric derisomaltose who received at least one infusion and all patients assigned to usual care. A COVID-19 sensitivity analysis censoring follow-up on Sept 30, 2020, was prespecified. IRONMAN is registered with ClinicalTrials.gov, NCT02642562. FINDINGS: Between Aug 25, 2016, and Oct 15, 2021, 1869 patients were screened for eligibility, of whom 1137 were randomly assigned to receive intravenous ferric derisomaltose (n=569) or usual care (n=568). Median follow-up was 2·7 years (IQR 1·8-3·6). 336 primary endpoints (22·4 per 100 patient-years) occurred in the ferric derisomaltose group and 411 (27·5 per 100 patient-years) occurred in the usual care group (rate ratio [RR] 0·82 [95% CI 0·66 to 1·02]; p=0·070). In the COVID-19 analysis, 210 primary endpoints (22·3 per 100 patient-years) occurred in the ferric derisomaltose group compared with 280 (29·3 per 100 patient-years) in the usual care group (RR 0·76 [95% CI 0·58 to 1·00]; p=0·047). No between-group differences in deaths or hospitalisations due to infections were observed. Fewer patients in the ferric derisomaltose group had cardiac serious adverse events (200 [36%]) than in the usual care group (243 [43%]; difference -7·00% [95% CI -12·69 to -1·32]; p=0·016). INTERPRETATION: For a broad range of patients with heart failure, reduced left ventricular ejection fraction and iron deficiency, intravenous ferric derisomaltose administration was associated with a lower risk of hospital admissions for heart failure and cardiovascular death, further supporting the benefit of iron repletion in this population. FUNDING: British Heart Foundation and Pharmacosmos
A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure
Objectives
Cardiac resynchronization therapy with a biventricular pacemaker (CRT-P) is an effective treatment for dyssynchronous heart failure (DHF). Adding an implantable cardioverter defibrillator (CRT-D) may further reduce the risk of sudden cardiac death (SCD). However, if the majority of patients do not require shock therapy, the cost-effectiveness ratio of CRT-D compared to CRT-P may be high. The objective of this study was to systematically review decision models evaluating the cost-effectiveness of CRT-D for patients with DHF, compare the structure and inputs of these models and identify the main factors influencing the ICERs for CRT-D.
Methods
A comprehensive search strategy of Medline (Ovid), Embase (Ovid) and EconLit identified eight cost-effectiveness models evaluating CRT-D against optimal pharmacological therapy (OPT) and/or CRT-P.
Results
The selected economic studies differed in terms of model structure, treatment path, time horizons, and sources of efficacy data. CRT-D was found cost-effective when compared to OPT but its cost-effectiveness became questionable when compared to CRT-P.
Conclusions
Cost-effectiveness of CRT-D may increase depending on improvement of all-cause mortality rates and HF mortality rates in patients who receive CRT-D, costs of the device, and battery life. In particular, future studies need to investigate longer-term mortality rates and identify CRT-P patients that will gain the most, in terms of life expectancy, from being treated with a CRT-D.This work was supported by the Center for Translational Molecular Medicine and The Netherlands Heart Foundation under the ‘Biomarkers to predict cardiac failure, arrhythmias and success of treatment’ (COHFAR) projec
Cardiac resynchronization therapy delivered via a multipolar left ventricular lead is associated with reduced mortality and elimination of phrenic nerve stimulation: long-term follow-up from a multicenter registry
Introduction
Cardiac resynchronization therapy (CRT) using quadripolar left ventricular (LV) leads provides more pacing vectors compared to bipolar leads. This may avoid phrenic nerve stimulation (PNS) and allow optimal lead placement to maximize biventricular pacing. However, a long-term improvement in patient outcome has yet to be demonstrated.
Methods
A total of 721 consecutive patients with conventional CRTD criteria implanted with quadripolar (n = 357) or bipolar (n = 364) LV leads were enrolled into a registry at 3 UK centers. Lead performance and mortality was analyzed over a 5-year period.
Results
Patients receiving a quadripolar lead were of similar age and sex to those receiving a bipolar lead, although a lower proportion had ischemic heart disease (62.6% vs. 54.1%, P = 0.02). Both groups had similar rates of procedural success, although lead threshold, impedance, and procedural radiation dose were significantly lower in those receiving a quadripolar lead. PNS was more common in those with quadripolar leads (16.0% vs. 11.6%, P = 0.08), but was eliminated by switching pacing vector in all cases compared with 60% in the bipolar group (P
Conclusions
In a large, multicenter experience, the use of quadripolar LV leads for CRT was associated with elimination of PNS and lower overall mortality. This has important implications for LV pacing lead choice.</p
Cardiac resynchronization therapy delivered via a multipolar left ventricular lead is associated with reduced mortality and elimination of phrenic nerve stimulation: Long-term follow-up from a multicenter registry
Introduction Cardiac resynchronization therapy (CRT) using quadripolar left ventricular (LV) leads provides more pacing vectors compared to bipolar leads. This may avoid phrenic nerve stimulation (PNS) and allow optimal lead placement to maximize biventricular pacing. However, a long-term improvement in patient outcome has yet to be demonstrated. Methods A total of 721 consecutive patients with conventional CRTD criteria implanted with quadripolar (n = 357) or bipolar (n = 364) LV leads were enrolled into a registry at 3 UK centers. Lead performance and mortality was analyzed over a 5-year period. Results Patients receiving a quadripolar lead were of similar age and sex to those receiving a bipolar lead, although a lower proportion had ischemic heart disease (62.6% vs. 54.1%, P = 0.02). Both groups had similar rates of procedural success, although lead threshold, impedance, and procedural radiation dose were significantly lower in those receiving a quadripolar lead. PNS was more common in those with quadripolar leads (16.0% vs. 11.6%, P = 0.08), but was eliminated by switching pacing vector in all cases compared with 60% in the bipolar group (P < 0.001). Furthermore, LV lead displacement (1.7% vs. 4.6%, P = 0.03) and repositioning (2.0% vs. 5.2%, P = 0.03) occurred significantly less often in those with a quadripolar lead. All-cause mortality was also significantly lower in the quadripolar compared to bipolar lead group in univariate and multivariate analysis (13.2% vs. 22.5%, P < 0.001). Conclusions In a large, multicenter experience, the use of quadripolar LV leads for CRT was associated with elimination of PNS and lower overall mortality. This has important implications for LV pacing lead choice