21 research outputs found

    Turbulent flow as a cause for underestimating coronary flow reserve measured by Doppler guide wire

    Get PDF
    BACKGROUND: Doppler-tipped coronary guide-wires (FW) are well-established tools in interventional cardiology to quantitatively analyze coronary blood flow. Doppler wires are used to measure the coronary flow velocity reserve (CFVR). The CFVR remains reduced in some patients despite anatomically successful coronary angioplasty. It was the aim of our study to test the influence of changes in flow profile on the validity of intra-coronary Doppler flow velocity measurements in vitro. It is still unclear whether turbulent flow in coronary arteries is of importance for physiologic studies in vivo. METHODS: We perfused glass pipes of defined inner diameters (1.5 – 5.5 mm) with heparinized blood in a pulsatile flow model. Laminar and turbulent flow profiles were achieved by varying the flow velocity. The average peak velocity (APV) was recorded using 0.014 inch FW. Flow velocity measurements were also performed in 75 patients during coronary angiography. Coronary hyperemia was induced by intra-coronary injection of adenosine. The APV maximum was taken for further analysis. The mean luminal diameter of the coronary artery at the region of flow velocity measurement was calculated by quantitative angiography in two orthogonal planes. RESULTS: In vitro, the measured APV multiplied with the luminal area revealed a significant correlation to the given perfusion volumes in all diameters under laminar flow conditions (r(2 )> 0.85). Above a critical Reynolds number of 500 – indicating turbulent flow – the volume calculation derived by FW velocity measurement underestimated the actual rate of perfusion by up to 22.5 % (13 ± 4.6 %). In vivo, the hyperemic APV was measured irrespectively of the inherent deviation towards lower velocities. In 15 of 75 patients (20%) the maximum APV exceeded the velocity of the critical Reynolds number determined by the in vitro experiments. CONCLUSION: Doppler guide wires are a valid tool for exact measurement of coronary flow velocity below a critical Reynolds number of 500. Reaching a coronary flow velocity above the velocity of the critical Reynolds number may result in an underestimation of the CFVR caused by turbulent flow. This underestimation of the flow velocity may reach up to 22.5 % compared to the actual volumetric flow. Cardiologists should consider this phenomena in at least 20 % of patients when measuring CFVR for clinical decision making

    Suboptimal herd performance amplifies the spread of infectious disease in the cattle industry

    Get PDF
    Farms that purchase replacement breeding cattle are at increased risk of introducing many economically important diseases. The objectives of this analysis were to determine whether the total number of replacement breeding cattle purchased by individual farms could be reduced by improving herd performance and to quantify the effects of such reductions on the industry-level transmission dynamics of infectious cattle diseases. Detailed information on the performance and contact patterns of British cattle herds was extracted from the national cattle movement database as a case example. Approximately 69% of beef herds and 59% of dairy herds with an average of at least 20 recorded calvings per year purchased at least one replacement breeding animal. Results from zero-inflated negative binomial regression models revealed that herds with high average ages at first calving, prolonged calving intervals, abnormally high or low culling rates, and high calf mortality rates were generally more likely to be open herds and to purchase greater numbers of replacement breeding cattle. If all herds achieved the same level of performance as the top 20% of herds, the total number of replacement beef and dairy cattle purchased could be reduced by an estimated 34% and 51%, respectively. Although these purchases accounted for only 13% of between-herd contacts in the industry trade network, they were found to have a disproportionately strong influence on disease transmission dynamics. These findings suggest that targeting extension services at herds with suboptimal performance may be an effective strategy for controlling endemic cattle diseases while simultaneously improving industry productivity

    Beach Features

    No full text

    A comparative Study of the Masticatory Efficiency in Complete Dentures Using Acrylic and Metal Occlusal Posterior Teeth—Photocolorimetric Analysis

    No full text
    Masticatory efficiency is always compromised in complete denture patients. The denture teeth with compromised occlusal anatomy and material further compound the inherent limitations of complete dentures. To compare the masticatory efficiency of patients with complete denture using acrylic and metal occlusal posterior teeth. Ten edentulous patients with well-formed ridges were selected. Complete dentures using acrylic and metal occlusal posterior teeth were fabricated. The masticatory efficiency was calculated using photo colorimeter. Complete dentures with 20° acrylic resin posterior teeth were fabricated for ten edentulous patients and masticatory efficiency was measured using raw beetroot as test food on a photocolorimeter after 10, 15, 20 strokes. The acrylic resin posterior teeth were replaced with metal occlusal posterior teeth on the same denture base. The masticatory efficiency was measured by the same method. The mean average percentage of masticatory efficiency with acrylic resin teeth and metal occlusal teeth were first calculated and statistical analysis was done using students unpaired t test. The average masticatory efficiency with acrylic teeth was 46.46% and metal occlusal teeth was 65.62, ‘t’ = 5.38. The difference between the mean average masticatory performance percentage with acrylic teeth and metal occlusal teeth was significant at 1% i.e. P < 0.01. Within the limitation of this study the average percentage value of masticatory efficiency improves considerably when metal occlusal teeth replace normal acrylic teeth without any alteration in position or relation
    corecore