518 research outputs found

    Non-thermal membrane effects of electromagnetic fields and therapeutic applications in oncology

    Get PDF
    The temperature-independent effects of electromagnetic fields (EMF) have been controversial for decades. Here, we critically analyze the available literature on non-thermal effects of radiofrequency (RF) and microwave EMF. We present a literature review of preclinical and clinical data on non-thermal antiproliferative effects of various EMF applications, including conventional RF hyperthermia (HT, cRF-HT). Further, we suggest and evaluate plausible biophysical and electrophysiological models to decipher non-thermal antiproliferative membrane effects. Available preclinical and clinical data provide sufficient evidence for the existence of non-thermal antiproliferative effects of exposure to cRF-HT, and in particular, amplitude modulated (AM)-RF-HT. In our model, transmembrane ion channels function like RF rectifiers and low-pass filters. cRF-HT induces ion fluxes and AM-RF-HT additionally promotes membrane vibrations at specific resonance frequencies, which explains the non-thermal antiproliferative membrane effects via ion disequilibrium (especially of Ca(2+)) and/or resonances causing membrane depolarization, the opening of certain (especially Ca(2+)) channels, or even hole formation. AM-RF-HT may be tumor-specific owing to cancer-specific ion channels and because, with increasing malignancy, membrane elasticity parameters may differ from that in normal tissues. Published literature suggests that non-thermal antiproliferative effects of cRF-HT are likely to exist and could present a high potential to improve future treatments in oncology

    Current state of the art of regional hyperthermia treatment planning: A review

    Get PDF
    Locoregional hyperthermia, i.e. increasing the tumor temperature to 40-45 °C using an external heating device, is a very effective radio and chemosensitizer, which significantly improves clinical outcome. There is a clear thermal dose-effect relation, but the pursued optimal thermal dose of 43 °C for 1 h can often not be realized due to treatment limiting hot spots in normal tissue. Modern heating devices have a large number of independent antennas, which provides flexible power steering to optimize tumor heating and minimize hot spots, but manual selection of optimal settings is difficult. Treatment planning is a very valuable tool to improve locoregional heating. This paper reviews the developments in treatment planning software for tissue segmentation, electromagnetic field calculations, thermal modeling and optimization techniques. Over the last decade, simulation tools have become more advanced. On-line use has become possible by implementing algorithms on the graphical processing unit, which allows real-time computations. The number of applications using treatment planning is increasing rapidly and moving on from retrospective analyses towards assisting prospective clinical treatment strategies. Some clinically relevant applications will be discussed

    Sediment flux and composition changes in canyons on a carbonate-siliciclastic margin: evidence from turbidite deposits along the Great Barrier Reef margin

    Get PDF
    The shelf edge and slope of the Great Barrier Reef is heavily incised by submarine canyons which terminate in the Queensland Trough. Traditionally, sedimentation on the margin has been investigated within the framework of idealized siliciclastic or carbonate systems, depending on whether rivers or shallow marine carbonate producers dominate supply. The widely accepted paradigm ('reciprocal' sedimentation) states that sea-level strongly influences shelf, slope and basin sedimentation, with siliciclastics dominating lowstand periods and carbonates dominating transgressions/highstands. However, recent work (e.g., Dunbar and Dickens, 2003) on cores from the slope and basin has challenged this view. These workers argue that accumulation of both siliciclastic and carbonate sediments varies in phase, with the highest rates observed during transgressions, lowest rates during lowstands and moderate sedimentation during highstands. Irrespective of which model is correct, exactly how the sediment (carbonate or siliciclastic) moves from the shelf to the basin, and the role of submarine canyons in this process is not understood. We address this problem directly by investigating sedimentation in the canyons bordering the GBR. Combining new multibeam bathymetry and seismic data with x-radiograph, magnetic susceptibility, insitu reflectance spectroscopy, grain size, CNS, petrologic, pollen and 14C AMS analyses of canyon cores off Cooktown and Cairns, we aim to establish the source, timing and frequency of turbidite events deposited in the canyons over the last glacial to interglacial cycle, thereby testing the competing models. Our preliminary data confirm that: (1) the canyons record a distinct sedimentary shift from siliciclastic turbidites to calciturbidites; (2) the siliciclastic turbidites were deposited before 28 ka - providing strong support for the "reciprocal" model of margin sedimentation; and (3) the canyons have been active throughout the last deglaciation and into the late Holocene

    Radiofrequency applicator concepts for simultaneous MR imaging and hyperthermia treatment of glioblastoma multiforme: a 298 MHz(7.0 Tesla) thermal magnetic resonancesimulation study

    Get PDF
    Glioblastoma multiforme is the most frequent and most aggressive malignant brain tumor with de facto no long term curation by the use of current multimodal therapeutic approaches. The efficacy of brachytherapy and enhancing interstitial hyperthermia has been demonstrated. RF heating at ultrahigh fields (B0=7.0T, f=298MHz) has the potential of delivering sufficiently large thermal dosage for hyperthermia of relatively large tumor areas. This work focuses on electromagnetic field (EMF) simulations and provides realistic applicator designs tailored for simultaneous RF heating and MRI. Our simulations took advantage of target volumes derived from patient data, and our preliminary results suggest that RF power can be focused to both a small tumor area and a large clinical target volume

    Magnetic resonance thermometry: methodology, pitfalls and practical solutions

    Get PDF
    Clinically established thermal therapies such as thermoablative approaches or adjuvant hyperthermia treatment rely on accurate thermal dose information for the evaluation and adaptation of the thermal therapy. Intratumoural temperature measurements have been correlated successfully with clinical end points. Magnetic resonance imaging is the most suitable technique for non-invasive thermometry avoiding complications related to invasive temperature measurements. Since the advent of MR thermometry two decades ago, numerous MR thermometry techniques have been developed, continuously increasing accuracy and robustness for in vivo applications. While this progress was primarily focused on relative temperature mapping, current and future efforts will likely close the gap towards quantitative temperature readings. These efforts are essential to benchmark thermal therapy efficiency, to understand temperature-related biophysical and physiological processes and to use these insights to set new landmarks for diagnostic and therapeutic applications. With that in mind, this review summarises and discusses advances in MR thermometry, providing practical considerations, pitfalls and technical obstacles constraining temperature measurement accuracy, spatial and temporal resolution in vivo. Established approaches and current trends in thermal therapy hardware are surveyed with respect to potential benefits for MR thermometry

    Thermal magnetic resonance: physics considerations and electromagnetic field simulations up to 23.5 Tesla (1GHz)

    Get PDF
    Background: Glioblastoma multiforme is the most common and most aggressive malign brain tumor. The 5-year survival rate after tumor resection and adjuvant chemoradiation is only 10 %, with almost all recurrences occurring in the initially treated site. Attempts to improve local control using a higher radiation dose were not successful so that alternative additive treatments are urgently needed. Given the strong rationale for hyperthermia as part of a multimodal treatment for patients with glioblastoma, non-invasive radio frequency (RF) hyperthermia might significantly improve treatment results. Methods: A non-invasive applicator was constructed utilizing the magnetic resonance (MR) spin excitation frequency for controlled RF hyperthermia and MR imaging in an integrated system, which we refer to as thermal MR. Applicator designs at RF frequencies 300 MHz, 500 MHz and 1GHz were investigated and examined for absolute applicable thermal dose and temperature hotspot size. Electromagnetic field (EMF) and temperature simulations were performed in human voxel models. RF heating experiments were conducted at 300 MHz and 500 MHz to characterize the applicator performance and validate the simulations. Results: The feasibility of thermal MR was demonstrated at 7.0 T. The temperature could be increased by ~11 °C in 3 min in the center of a head sized phantom. Modification of the RF phases allowed steering of a temperature hotspot to a deliberately selected location. RF heating was monitored using the integrated system for MR thermometry and high spatial resolution MRI. EMF and thermal simulations demonstrated that local RF hyperthermia using the integrated system is feasible to reach a maximum temperature in the center of the human brain of 46.8 °C after 3 min of RF heating while surface temperatures stayed below 41 °C. Using higher RF frequencies reduces the size of the temperature hotspot significantly. Conclusion: The opportunities and capabilities of thermal magnetic resonance for RF hyperthermia interventions of intracranial lesions are intriguing. Employing such systems as an alternative additive treatment for glioblastoma multiforme might be able to improve local control by "fighting fire with fire". Interventions are not limited to the human brain and might include temperature driven targeted drug and MR contrast agent delivery and help to understand temperature dependent bio- and physiological processes in-vivo

    Design and evaluation of a hybrid radiofrequency applicator for magnetic resonance imaging and RF induced hyperthermia: electromagnetic field simulations up to 14.0 Tesla and proof-of-concept at 7.0 Tesla

    Get PDF
    This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B0>/=7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employed. Electromagnetic field simulations (EMF) were performed to study RF heating versus RF wavelength (frequency range: 64 MHz (1.5T) to 600 MHz (14.0T)). The experimental version of the applicator was implemented at B0 = 7.0T. The applicators feasibility for targeted RF heating was evaluated in EMF simulations and in phantom studies. Temperature co-simulations were conducted in phantoms and in a human voxel model. Our results demonstrate that higher frequencies afford a reduction in the size of specific absorption rate (SAR) hotspots. At 7T (298 MHz) the hybrid applicator yielded a 50% iso-contour SAR (iso-SAR-50%) hotspot with a diameter of 43 mm. At 600 MHz an iso-SAR-50% hotspot of 26 mm in diameter was observed. RF power deposition per RF input power was found to increase with B0 which makes targeted RF heating more efficient at higher frequencies. The applicator was capable of generating deep-seated temperature hotspots in phantoms. The feasibility of 2D steering of a SAR/temperature hotspot to a target location was demonstrated by the induction of a focal temperature increase (DeltaT = 8.1 K) in an off-center region of the phantom. Temperature simulations in the human brain performed at 298 MHz showed a maximum temperature increase to 48.6C for a deep-seated hotspot in the brain with a size of (19x23x32)mm(3) iso-temperature-90%. The hybrid applicator provided imaging capabilities that facilitate high spatial resolution brain MRI. To conclude, this study outlines the technical underpinnings and demonstrates the basic feasibility of an 8-channel hybrid TX/RX applicator that supports MR imaging, MR thermometry and targeted RF heating in one device