115 research outputs found
Accurately accounting for effects on times-of-flight caused by finite field-transition times during the ejection of ions from a storage trap: A study for TOF and MRTOF mass spectrometry
In applied forms of time-of-flight mass spectrometry utilizing ion storage
devices prior to an analysis device, a non instantaneous electric ejection
pulse applied in the region of ion storage is used to accelerate ions into the
time-of-flight analyzer. The calculated mass value of the ions from the
time-of-flight is dependent on the duration of the field transition up to full
strength. For novel applications dedicated to precision measurements, such as
multi-reflection time-of-flight mass spectrometry of short-lived isotopes, the
goal is to continuously decrease the measurement uncertainty while providing a
mass accuracy on the same order. Even though dynamic-field models for
time-of-flight mass spectrometry have been considered in the past for
technological advances, it is important to study the accuracy of the measured
mass in this context. Using a simplified linear model for the field transition,
we provide a basic investigation of the scenario, and discuss the deviation
from the classical "mass-over-charge" dependency of the ions' time-of-flight,
which becomes violated. The emerging mass discrepancy depends on the distance
between the mass of the ion used for calibration and that of the ion of
interest and, in extreme cases, can increase to about one percent for systems
with short times-of-flight. However, for typical conditions in single-reference
multi-reflection time-of-flight mass spectrometry, mass deviations caused by
this effect typically remain below the 1 ppm level. If a mass calibration using
two or more ion species is possible during the measurement, the effect becomes
negligible for appropriate choices of reference masses.Comment: 14 pages, 9 figure
Nuclear spectroscopy of r-process nuclei around N = 126 using KISS
The beta-decay properties and atomic mass of nuclei with neutron magic number of N = 126 are considered critical for understanding the production of heavy elements such as gold and platinum at astrophysical sites. We will produce and measure the half-lives and masses of the nuclei with Z = 74–77 around N = 126 by using the multinucleon transfer (MNT) reaction of 136Xe/238U beams and198Pt target system. For this purpose, we have constructed the KEK Isotope Separation System (KISS) at RIKEN RIBF facility. KISS consists of an argon gas cell based laser ion source (atomic number selection) and an isotope separation on-line (ISOL) (mass number selection), to produce pure low-energy beams of neutron-rich isotopes around N = 126. We performed the on-line tests to study the basic properties of the KISS and, successfully extracted laser-ionized nuclei around N = 126
Atomic masses of intermediate-mass neutron-deficient nuclei with relative uncertainty down to 35-ppb via multireflection time-of-flight mass spectrograph
High-precision mass measurements of Cu, Zn, Ga,
Ge, As, Br, Rb, and Sr were performed
utilizing a multireflection time-of-flight mass spectrograph combined with the
gas-filled recoil ion separator GARIS-II. In the case of Ga, a mass
uncertainty of 2.1 keV, corresponding to a relative precision of , was obtained and the mass value is in excellent agreement
with the 2016 Atomic Mass Evaluation. For Ge and Br, where masses
were previously deduced through indirect measurements, discrepancies with
literature values were found. The feasibility of using this device for mass
measurements of nuclides more neutron-deficient side, which have significant
impact on the -process pathway, is discussed.Comment: 15 pages, 6 figures, 1 tabl
- …