36 research outputs found

    Modal Analysis and Coupling in Metal-Insulator-Metal Waveguides

    Full text link
    This paper shows how to analyze plasmonic metal-insulator-metal waveguides using the full modal structure of these guides. The analysis applies to all frequencies, particularly including the near infrared and visible spectrum, and to a wide range of sizes, including nanometallic structures. We use the approach here specifically to analyze waveguide junctions. We show that the full modal structure of the metal-insulator-metal (MIM) waveguides--which consists of real and complex discrete eigenvalue spectra, as well as the continuous spectrum--forms a complete basis set. We provide the derivation of these modes using the techniques developed for Sturm-Liouville and generalized eigenvalue equations. We demonstrate the need to include all parts of the spectrum to have a complete set of basis vectors to describe scattering within MIM waveguides with the mode-matching technique. We numerically compare the mode-matching formulation with finite-difference frequency-domain analysis and find very good agreement between the two for modal scattering at symmetric MIM waveguide junctions. We touch upon the similarities between the underlying mathematical structure of the MIM waveguide and the PT symmetric quantum mechanical pseudo-Hermitian Hamiltonians. The rich set of modes that the MIM waveguide supports forms a canonical example against which other more complicated geometries can be compared. Our work here encompasses the microwave results, but extends also to waveguides with real metals even at infrared and optical frequencies.Comment: 17 pages, 13 figures, 2 tables, references expanded, typos fixed, figures slightly modifie

    An Absolute Measurement of the Cosmic Microwave Background Radiation Temperature at 10.7 GHz

    Get PDF
    A balloon-borne experiment has measured the absolute temperature of the cosmic microwave background radiation (CMBR) at 10.7 GHz to be Tcmbr = 2.730 +- .014 K. The error is the quadratic sum of several systematic errors, with statistical error of less than 0.1 mK. The instrument comprises a cooled corrugated horn antenna coupled to a total-power radiometer. A cryogenic mechanical waveguide switch alternately connects the radiometer to the horn and to an internal reference load. The small measured temperature difference (<= 20 mK) between the sky signal and the reference load in conjunction with the use of a cold front end keeps systematic instrumental corrections small. Atmospheric and window emission are minimized by flying the instrument at 24 km altitude. A large outer ground screen and smaller inner screen shield the instrument from stray radiation from the ground and the balloon. In-flight tests constrain the magnitude of ground radiation contamination, and low level interference is monitored through observations in several narrow frequency bands.Comment: 14 pages, 1 figure, submitted to ApJ

    CMB Telescopes and Optical Systems

    Full text link
    The cosmic microwave background radiation (CMB) is now firmly established as a fundamental and essential probe of the geometry, constituents, and birth of the Universe. The CMB is a potent observable because it can be measured with precision and accuracy. Just as importantly, theoretical models of the Universe can predict the characteristics of the CMB to high accuracy, and those predictions can be directly compared to observations. There are multiple aspects associated with making a precise measurement. In this review, we focus on optical components for the instrumentation used to measure the CMB polarization and temperature anisotropy. We begin with an overview of general considerations for CMB observations and discuss common concepts used in the community. We next consider a variety of alternatives available for a designer of a CMB telescope. Our discussion is guided by the ground and balloon-based instruments that have been implemented over the years. In the same vein, we compare the arc-minute resolution Atacama Cosmology Telescope (ACT) and the South Pole Telescope (SPT). CMB interferometers are presented briefly. We conclude with a comparison of the four CMB satellites, Relikt, COBE, WMAP, and Planck, to demonstrate a remarkable evolution in design, sensitivity, resolution, and complexity over the past thirty years.Comment: To appear in: Planets, Stars and Stellar Systems (PSSS), Volume 1: Telescopes and Instrumentatio

    Non-periodic Slow-wave and Backward Wave Structures

    No full text

    International Space Station Electromagnetic Environment

    No full text
    corecore