1,155 research outputs found
Affective variability in depression:Revisiting the inertia-instability paradox
How can depression be associated with both instability and inertia of affect? Koval et al. (2013, Emotion, 13, 1132) showed that this paradox can be solved by accounting for the statistical overlap between measures of affect dynamics. Nevertheless, these measures are still often studied in isolation. The present study is a replication of the Koval et al. study. We used experience sampling data (three times a day, 1 month) of 462 participants from the general population and a subsample thereof (N = 100) selected to reflect a uniform range of depressive symptoms. Dynamics measures were calculated for momentary negative affect scores. When adjusting for the overlap among affect dynamics measures, depression was associated with 'dispersion' (SD) but not 'instability' (RMSSD) or 'inertia' (AR) of negative affect. The association between dispersion and depression became non-significant when mean levels of negative affect were adjusted for. These findings substantiate the evidence that the presumed association between depression and instability is largely accounted for by the SD, while the association between dispersion and depression may largely reflect mean levels of affect. Depression may thus not be related to higher instability per se, which would be in line with theories on the adaptive function of moment-to-moment fluctuations in affect
Evaluating 35 Methods to Generate Structural Connectomes Using Pairwise Classification
There is no consensus on how to construct structural brain networks from
diffusion MRI. How variations in pre-processing steps affect network
reliability and its ability to distinguish subjects remains opaque. In this
work, we address this issue by comparing 35 structural connectome-building
pipelines. We vary diffusion reconstruction models, tractography algorithms and
parcellations. Next, we classify structural connectome pairs as either
belonging to the same individual or not. Connectome weights and eight
topological derivative measures form our feature set. For experiments, we use
three test-retest datasets from the Consortium for Reliability and
Reproducibility (CoRR) comprised of a total of 105 individuals. We also compare
pairwise classification results to a commonly used parametric test-retest
measure, Intraclass Correlation Coefficient (ICC).Comment: Accepted for MICCAI 2017, 8 pages, 3 figure
CVM studies on the atomic ordering in complex perovskite alloys
The atomic ordering in complex perovskite alloys is investigated by the
cluster variation method (CVM). For the 1/3\{111\}-type ordered structure, the
order-disorder phase transition is the first order, and the order parameter of
the 1:2 complex perovskite reaches its maximum near x=0.25. For the
1/2\{111\}-type ordered structure, the ordering transition is the second order.
Phase diagrams for both ordered structures are obtained. The order-disorder
line obeys the linear law.Comment: 10 pages, 6 figure
Initial elevation bias in subjective reports
Peer reviewedPostprin
Development of Ferroelectric Order in Relaxor (1-x)Pb(Mg1/3Nb2/3)O3 - xPbTiO3
The microstructure and phase transition in relaxor ferroelectric
Pb(Mg1/3Nb2/3)O3 (PMN) and its solid solution with PbTiO3 (PT), PMN-xPT, remain
to be one of the most puzzling issues of solid state science. In the present
work we have investigated the evolution of the phase symmetry in PMN-xPT
ceramics as a function of temperature (20 K < T < 500 K) and composition (0 <=
x <= 0.15) by means of high-resolution synchrotron x-ray diffraction.
Structural analysis based on the experimental data reveals that the
substitution of Ti^4+ for the complex B-site (Mg1/3Nb2/3)^4+ ions results in
the development of a clean rhombohedral phase at a PT-concentration as low as
5%. The results provide some new insight into the development of the
ferroelectric order in PMN-PT, which has been discussed in light of the
kinetics of polar nanoregions and the physical models of the relaxor
ferroelectrics to illustrate the structural evolution from a relaxor to a
ferroelectric state.Comment: Revised version with updated references; 9 pages, 4 figures embedde
3D Variation in delineation of head and neck organs at risk
<p>Abstract</p> <p>Background</p> <p>Consistent delineation of patient anatomy becomes increasingly important with the growing use of highly conformal and adaptive radiotherapy techniques. This study investigates the magnitude and 3D localization of interobserver variability of organs at risk (OARs) in the head and neck area with application of delineation guidelines, to establish measures to reduce current redundant variability in delineation practice.</p> <p>Methods</p> <p>Interobserver variability among five experienced radiation oncologists was studied in a set of 12 head and neck patient CT scans for the spinal cord, parotid and submandibular glands, thyroid cartilage, and glottic larynx. For all OARs, three endpoints were calculated: the Intraclass Correlation Coefficient (ICC), the Concordance Index (CI) and a 3D measure of variation (3D SD).</p> <p>Results</p> <p>All endpoints showed largest interobserver variability for the glottic larynx (ICC = 0.27, mean CI = 0.37 and 3D SD = 3.9 mm). Better agreement in delineations was observed for the other OARs (range, ICC = 0.32-0.83, mean CI = 0.64-0.71 and 3D SD = 0.9-2.6 mm). Cranial, caudal, and medial regions of the OARs showed largest variations. All endpoints provided support for improvement of delineation practice.</p> <p>Conclusions</p> <p>Variation in delineation is traced to several regional causes. Measures to reduce this variation can be: (1) guideline development, (2) joint delineation review sessions and (3) application of multimodality imaging. Improvement of delineation practice is needed to standardize patient treatments.</p
A Valid and Reliable Instrument for Cognitive Complexity Rating Assignment of Chemistry Exam Items
The design and use of a valid and reliable instrument for the assignment of cognitive complexity ratings to chemistry exam items is described in this paper. Use of such an instrument provides a simple method to quantify the cognitive demands of chemistry exam items. Instrument validity was established in two different ways: statistically significant correlations between expert-based cognitive complexity ratings and student performance (as measured through statistical difficulty of items), and statistically significant correlations between expert-based cognitive complexity ratings and student mental effort ratings. Key benefits associated with instrument use include an enhanced understanding of the cognitive complexity of chemistry assessment tasks and as a means for characterizing exam content for the measurement of cognitive development
On passion and moral behavior in achievement settings: The mediating role of pride
The Dualistic Model of Passion (Vallerand et al., 2003) distinguishes two types of passion: harmonious passion (HP) and obsessive passion (OP) that predict adaptive and less adaptive outcomes, respectively. In the present research, we were interested in understanding the role of passion in the adoption of moral behavior in achievement settings. It was predicted that the two facets of pride (authentic and hubristic; Tracy & Robins, 2007) would mediate the passion-moral behavior relationship. Specifically, because people who are passionate about a given activity are highly involved in it, it was postulated that they should typically do well and thus experience high levels of pride when engaged in the activity. However, it was also hypothesized that while both types of passion should be conducive to authentic pride, only OP should lead to hubristic pride. Finally, in line with past research on pride (Carver, Sinclair, & Johnson, 2010; Tracy et al., 2009), only hubristic pride was expected to negatively predict moral behavior, while authentic pride was expected to positively predict moral behavior. Results of two studies conducted with paintball players (N=163, Study 1) and athletes (N=296, Study 2) supported the proposed model. Future research directions are discussed in light of the Dualistic Model of Passion
The temporal reliability of serum estrogens, progesterone, gonadotropins, SHBG and urinary estrogen and progesterone metabolites in premenopausal women
BACKGROUND: There is little existing research to guide researchers in estimating the minimum number of measurement occasions required to obtain reliable estimates of serum estrogens, progesterone, gonadotropins, sex hormone-binding globulin (SHBG), and urinary estrogen and progesterone metabolites in premenopausal women. METHODS: Using data from a longitudinal study of 34 women with a mean age of 42.3 years (SD = 2.6), we calculated the minimum number of measurement occasions required to obtain reliable estimates of 12 analytes (8 in blood, 4 in urine). Five samples were obtained over 1 year: at baseline, and after 1, 3, 6, and 12 months. We also calculated the percent of true variance accounted for by a single measurement and intraclass correlation coefficients (ICC) between measurement occasions. RESULTS: Only 2 of the 12 analytes we examined, SHBG and estrone sulfate (E(1)S), could be adequately estimated by a single measurement using a minimum reliability standard of having the potential to account for 64% of true variance. Other analytes required from 2 to 12 occasions to account for 81% of the true variance, and 2 to 5 occasions to account for 64% of true variance. ICCs ranged from 0.33 for estradiol (E(2)) to 0.88 for SHBG. Percent of true variance accounted for by single measurements ranged from 29% for luteinizing hormone (LH) to 92% for SHBG. CONCLUSIONS: Experimental designs that take the natural variability of these analytes into account by obtaining measurements on a sufficient number of occasions will be rewarded with increased power and accuracy
Electric toothbrush application is a reliable and valid test for differentiating temporomandibular disorders pain patients from controls
<p>Abstract</p> <p>Background</p> <p>Current methods for identifying patients with pain hypersensitivity are sufficiently complex to limit their widespread application in clinical settings. We assessed the reliability and validity of a simple multi-modal vibrotactile stimulus, applied using an electric toothbrush, to evaluate its potential as a screening tool for central sensitization.</p> <p>Methods</p> <p>Fourteen female temporomandibular disorders (TMD) subjects with myofascial pain (RDC/TMD Ia or Ib) and arthralgia (RDC/TMD IIIa) were compared to 13 pain-free controls of matched age and gender. Vibrotactile stimulus was performed with an electric toothbrush, applied with 1 pound pressure for 30 seconds in four locations: over the lateral pole of the temporomandibular joint, masseter, temporalis, and mid-ventral surface of forearm. Pain intensity (0–10) was recorded following the stimulus at 0, 15, 30, and 60 seconds. Test-retest reliability was assessed with measurements from 8 participants, taken 2–12 hours apart. Case versus control differentiation involved comparison of area under the curve (AUC). A receiver operating characteristic (ROC) curve was used to determine cutoff AUC scores for maximum sensitivity and specificity for this multi-modal vibrotactile stimulus.</p> <p>Results</p> <p>Test-retest reliability resulted in an ICC of 0.87 for all 4 pooled sites. ROC-determined AUC cutoff scores resulted in a sensitivity of 57% and specificity of 92% for all 4 pooled sites.</p> <p>Conclusion</p> <p>The electric toothbrush stimulus had excellent test-retest reliability. Validity of the scores was demonstrated with modest sensitivity and good specificity for differentiating TMD pain patients from controls, which are acceptable properties for a screening test.</p
- …