Optimization, Application, and Interpretation of Lactate Dehydrogenase Measurements in Microwell Determination of Cell Number and Toxicity
The lactate dehydrogenase (LDH) assay was addressed for its sensitivity, disturbances by foaming, and cell number and size. Cells were from a U-251 MG grade IV human glioblastoma brain tumor cell line used in 100-µl well volumes. Cells were counted by microscopy and Coulter counting; assays were LDH or trypan blue. The results indicate increased 490 nm signals (level, variance) by using phenol red or by increasing fetal bovine serum from 5% to 10%. The data also indicate that defoaming results in reduced variances ranging from a factor of 2 at 1–3 units of absorption, up to a factor of 4–5 at <1 units of absorption. Coulter counting indicated a decrease in cell volume with increasing end-point cell density, attributed to general shrinking at increasing density. In comparisons, total LDH was considered relative to both cell total volume and cell numbers. The result suggests that total LDH should be regarded as reflecting cell total volume rather than cell numbers. In a comparative Cu exposure test, signals of both LDH and a sodium salt of 4-[3-(4-iodophenyl)-2-(4-nitrophenyl)-2H-5-tetrazolio]-1,3-benzene disulfonate (WST-1) decreased with increasing Cu supply, while bromodeoxyuridine signals remained largely unaffected. The data show the differences in responses in cell viability and proliferation, but, above all, indicate that LDH should be expressed on a per cell volume basis rather than per cell, to avoid the problem that mere density effects contribute to signals on compound or metal toxicity.RST/Radiation, Science and TechnologyApplied Science
On-line monitoring of infected Sf-9 insect cell cultures by scanning permittivity measurements and comparison with off-line biovolume measurements
Two infected Sf-9 cell cultures were monitored on-line by multi-frequency permittivity measurements using the Fogale BIOMASS SYSTEM® and by applying different off-line methods (CASY®1, Vi-CELL™, packed cell volume) to measure the biovolume and the mean diameter of the cell population. During the growth phase and the early infection phase the measured permittivity at the working frequency correlated well with the different off-line methods for the biovolume. We found a value of 0.67 pF cm−1 permittivity per unit of total biovolume (CASY) (μL mL−1). After the maximum value in the permittivity was reached, i.e. when the viability of the cultures decreased significantly, we observed different time courses for the biovolume depending on the applied method. The differences were compared and could be explained by the underlying measurement principles. Furthermore, the characteristic frequency (fC) was calculated from the on-line scanning permittivity measurements. The fC may provide an indication of changes in cell diameter and membrane properties especially after infection and could also be an indicator for the onset of the virus production phase. The changes in fC were qualitatively explained by the underlying equation that is correlating fC and the properties of the cell population (cell diameter, intracellular conductivity and capacitance per membrane area)