2,215 research outputs found

    Coronary flow: a new asset for the echo lab?

    Get PDF

    Coronary flow reserve of the angiographically normal left anterior descending coronary artery in patients with remote coronary artery disease

    Get PDF
    Coronary artery disease (CAD) has been suggested to alter coronary flow reserve (CFR; the ratio between hyperemic and baseline coronary flow velocities) not only in territories supplied by stenotic arteries but also in angiographically normal, remote regions. However, few data exist regarding the left anterior descending (LAD) coronary artery as the normal index artery. The influence of remote CAD on CFR of the angiographically normal LAD was evaluated with transthoracic Doppler ultrasound to measure CFR in the LAD during 90 seconds of venous adenosine infusion (140 microg/kg/min) in 122 subjects who were assigned to 1 group; group 1 comprised 49 controls without angiographically detectable CAD, and group 2 consisted of 73 patients with an angiographically normal LAD and remote CAD. Group 2 was divided into 4 subgroups: 16 patients with previous remote percutaneous coronary intervention (group 2A); 13 patients with significant remote stenosis (group 2B); 23 patients with previous remote myocardial infarction and percutaneous coronary intervention (group 2C); and 21 patients with previous remote myocardial infarction but no percutaneous coronary intervention (group 2D). CFR in the LAD was not significantly different in groups 1 and 2 (3.08 +/- 0.61 and 3.03 +/- 0.69, respectively, p = NS). Decreased ejection fraction and increased wall motion score index in patients with remote CAD (p < 0.00001) and multivessel CAD did not affect CFR in the LAD (group 2A 3.18 +/- 0.77; group 2B 3.05 +/- 0.65; group 2C 3.07 +/- 0.79; group 2D 2.86 +/- 0.50, respectively; F = 0.63, p = NS). In conclusion, CFR of an angiographically normal LAD is preserved in patients with remote CAD, even in the presence of previous remote myocardial infarction and wall motion abnormalities

    Functional assessment of the collateral-dependent circulation in chronic total coronary occlusion using transthoracic Doppler ultrasound and venous adenosine infusion

    Get PDF
    The measurement of collateral flow reserve (CFR; the hyperemic/baseline collateral flow velocity ratio) in patients with chronic total coronary occlusion requires invasive and expensive techniques. Noninvasive transthoracic coronary Doppler echocardiography may be an alternative option. Fifty-one patients with chronic total coronary occlusion were evaluated by transthoracic coronary Doppler echocardiography and venous adenosine infusion to measure CFR in occluded coronary arteries (the left anterior descending artery in 44 patients and the artery supplying the posterior descending artery in 7 patients). CFR data were plotted against 3 angiographic parameters: (1) grade of the epicardial filling of the occluded artery (1=absent, 2=partial, 3=complete), (2) stenosis of the donor artery, and (3) the extent of coronary artery disease (vessels with >or=70% stenosis). Collateral flow was maintained at stress in 34 patients (CFR>or=1, range 1.0 to 2.2) but was withdrawn in 17 patients (CFR<1, range 0.25 to 0.90). CFR increased with the degree of angiographic collateral flow (grade 1: 0.73+/-0.29; grade 2: 1.16+/-0.31; grade 3: 1.34+/-0.49; F=5.31, p=0.008). A multivariate model of CFR prediction showed a direct relation with angiographic collateral grade and the number of diseased vessels and an inverse relation with stenosis of the donor artery. In conclusion, CFR measurement is feasible by transthoracic coronary Doppler echocardiography. One third of the patients with chronic total coronary occlusion had collateral flow withdrawal at stress, which occurs when collateral circulation is poor and when the donor artery is stenotic. CFR correlates with angiographic collateral grade and with the extent of coronary artery disease

    Electrocardiographic markers of structural heart disease and predictors of death in 2332 unselected patients undergoing outpatient Holter recording

    Get PDF
    To test the hypothesis that the QS interval of ventricular ectopic beats (VEBs) (ventricular ectopic QS interval, VEQSI) would provide a marker for the presence of structural heart disease and a predictor of mortality

    Silybin counteracts lipid excess and oxidative stress in cultured steatotic hepatic cells

    Get PDF
    AIM: To investigate in vitro the therapeutic effect and mechanisms of silybin in a cellular model of hepatic steatosis. METHODS: Rat hepatoma FaO cells were loaded with lipids by exposure to 0.75 mmol/L oleate/palmitate for 3 h to mimic liver steatosis. Then, the steatotic cells were incubated for 24 h with different concentrations (25 to 100 mol/L) of silybin as phytosome complex with Vitamin E. The effects of silybin on lipid accumulation and metabolism, and on indices of oxidative stress were evaluated by absorption and fluorescence microscopy, quantitative real-time PCR, Western blot, spectrophotometric and fluorimetric assays. RESULTS: Lipid-loading resulted in intracellular triglyceride (TG) accumulation inside lipid droplets, whose number and size increased. TG accumulation was mediated by increased levels of peroxisome proliferator-activated receptors (PPARs) and sterol regulatory element-binding protein-1c (SREBP-1c). The lipid imbalance was associated with higher production of reactive oxygen species (ROS) resulting in increased lipid peroxidation, stimulation of catalase activity and activation of nuclear factor kappa-B (NF-B). Incubation of steatotic cells with silybin 50 mol/L significantly reduced TG accumulation likely by promoting lipid catabolism and by inhibiting lipogenic pathways, as suggested by the changes in carnitine palmitoyltransferase 1 (CPT-1), PPAR and SREBP-1c levels. The reduction in fat accumulation exerted by silybin in the steatotic cells was associated with the improvement of the oxidative imbalance caused by lipid excess as demonstrated by the reduction in ROS content, lipid peroxidation, catalase activity and NF-B activation

    Recovery of distal coronary flow reserve in LAD and LCx after Y-Graft intervention assessed by transthoracic echocardiography

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Y- graft (Y-G) is a graft formed by the Left Internal Mammary Artery (LIMA) connected to the Left Anterior Descending Artery (LAD) and by a free Right Internal Mammary Artery (RIMA) connected to LIMA and to a Marginal artery of Left Circumflex Artery (LCx). Aim of the work was to study the flow of this graft during a six months follow-up to assess whether the graft was able to meet the request of all the left coronary circulation, and to assess whether it could be done by evaluation of coronary flow reserve (CFR).</p> <p>Methods</p> <p>In 13 consecutive patients submitted to Y-G (13 men), CFR was measured in distal LAD and in distal LCx from 1 week after , every two months, up to six months after operation (a total of 8 tests for each patient) by means of transthoracic echocardiography (TTE) and Adenosine infusion (140 mcg/kg/min for 3-6 min). A Sequoia 256, Acuson-Siemens, was used. Contrast was used when necessary (Levovist 300 mg/ml solution at a rate of 0,5-1 ml/min). Max coronary flow diastolic velocity post-/pre-test ≥2 was considered normal CFR.</p> <p>Results</p> <p>Coronary arteriography revealed patency of both branches of Y-G after six months. Accuracy of TTE was 100% for LAD and 85% for LCx. Feasibility was 100% for LAD and 85% for LCx. CFR improved from baseline in LAD (2.21 ± 0.5 to 2.6 ± 0.5, p = 0.03) and in LCx (1.7 ± 1 to 2.12 ± 1, p = 0.05). CFR was under normal at baseline in 30% of patients <it>vs </it>8% after six months in LAD (p = 0.027), and in 69% of patients <it>vs </it>30% after six months in LCx (p = 0.066).</p> <p>Conclusion</p> <p>CFR in Y-G is sometimes reduced in both left territories postoperatively but it improves at six months follow-up. A follow-up can be done non-invasively by TTE and CFR evaluation.</p

    Design and Test of a Forward Neutron Calorimeter for the ZEUS Experiment

    Get PDF
    A lead scintillator sandwich sampling calorimeter has been installed in the HERA tunnel 105.6 m from the central ZEUS detector in the proton beam direction. It is designed to measure the energy and scattering angle of neutrons produced in charge exchange ep collisions. Before installation the calorimeter was tested and calibrated in the H6 beam at CERN where 120 GeV electrons, muons, pions and protons were made incident on the calorimeter. In addition, the spectrum of fast neutrons from charge exchange proton-lucite collisions was measured. The design and construction of the calorimeter is described, and the results of the CERN test reported. Special attention is paid to the measurement of shower position, shower width, and the separation of electromagnetic showers from hadronic showers. The overall energy scale as determined from the energy spectrum of charge exchange neutrons is compared to that obtained from direct beam hadrons.Comment: 45 pages, 22 Encapsulated Postscript figures, submitted to Nuclear Instruments and Method

    Differences in duration of anticoagulation after pulmonary embolism and deep vein thrombosis: Findings from the SWIss Venous ThromboEmbolism Registry (SWIVTER).

    Get PDF
    BACKGROUND Although the two manifestations of venous thromboembolism (VTE), deep vein thrombosis (DVT) and pulmonary embolism (PE), vary considerably, the consensus guidelines recommend similar algorithms for therapeutic anticoagulation in both conditions. Real-world data assessing contemporary management strategies in PE and DVT alone may help tailoring future recommendations towards more individualized patient care. METHODS In the present analysis, we compared demographics, comorbidities, treatment patterns, and clinical outcomes of PE versus DVT only among 2062 consecutive patients with confirmed VTE enrolled by 11 acute care hospitals between November 2012 and February 2015 in the SWIss Venous ThromboEmbolism Registry (SWIVTER). RESULTS Overall, 1246 (60 %) patients were diagnosed with PE. In comparison to DVT alone, PE patients were older (66 vs. 59 years; p < 0.001), more frequently had acute and chronic comorbidities, less frequently had prior VTE and hormone replacement, and were less often pregnant. VTE was considered similarly often provoked in patients with PE and DVT alone (33.8 % vs. 33.5 %; p = 0.88). Anticoagulation for an indefinite duration was more often prescribed to patients with PE than those with DVT alone (45.7 vs. 19.6 %; p < 0.001), and PE diagnosis was the strongest independent predictor of indefinite anticoagulation (OR 3.21; 95 % CI 2.55-4.06; p < 0.001). Diagnosis of PE was associated with both increased risk of 90-day mortality (HR 2.31, 95 % CI 1.44-3.71; p = 0.001) and major bleeding (HR 3.88, 95 % CI 1.63-9.22; p = 0.002). CONCLUSIONS Our analysis affirms differences in demographics, risk factors, and clinical outcomes of PE versus DVT alone. In routine clinical practice, duration of anticoagulation is being managed differently between the two manifestations of VTE, in contrast to recommendations of the current consensus guidelines

    Persistent left superior vena cava: a case report and review of literature

    Get PDF
    Persistent left superior vena cava is rare but important congenital vascular anomaly. It results when the left superior cardinal vein caudal to the innominate vein fails to regress. It is most commonly observed in isolation but can be associated with other cardiovascular abnormalities including atrial septal defect, bicuspid aortic valve, coarctation of aorta, coronary sinus ostial atresia, and cor triatriatum. The presence of PLSVC can render access to the right side of heart challenging via the left subclavian approach, which is a common site of access utilized when placing pacemakers and Swan-Ganz catheters. Incidental notation of a dilated coronary sinus on echocardiography should raise the suspicion of PLSVC. The diagnosis should be confirmed by saline contrast echocardiography

    Feasibility and diagnostic power of transthoracic coronary Doppler for coronary flow velocity reserve in patients referred for myocardial perfusion imaging

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Myocardial perfusion imaging (MPI), using single photon emission computed tomography (SPECT) is a validated method for detecting coronary artery disease. Transthoracic Doppler echocardiography (TTDE) of flow at rest and during adenosine provocation has previously been evaluated in selected patient groups. We therefore wanted to compare the diagnostic ability of TTDE in the left anterior descending coronary artery (LAD) to that of MPI in an unselected population of patients with chest pain referred for MPI. Our hypothesis was that TTDE with high accuracy would identify healthy individuals and exclude them from the need for further studies, enabling invasive investigations to be reserved for patients with a high probability of disease.</p> <p>Methods</p> <p>Sixty-nine patients, 44 men and 25 women, age 61 ± 10 years (range 35–82), with a clinical suspicion of stress induced myocardial ischemia, were investigated. TTDE was performed at rest and during adenosine stress for myocardial scintigraphy.</p> <p>Results</p> <p>We found that coronary flow velocity reserve (CFVR) determined from diastolic measurements separated normal from abnormal MPI findings with statistical significance. TTDE identified coronary artery disease, defined from MPI, as reversible ischemia and/or permanent defect, with a sensitivity of 60% and a specificity of 79%. The positive predictive value was 43% and the negative predictive value was 88%. There was an overlap between groups which could be due to abnormal endothelial function in patients with normal myocardial perfusion having either hypertension or diabetes.</p> <p>Conclusion</p> <p>TTDE is an attractive non-invasive method to evaluate chest pain without the use of isotopes, but the diagnostic power is strongly dependent on the population investigated. Even in our heterogeneous clinical cardiac population, we found that CFVR>2 in the LAD excluded significant coronary artery disease detected by MPI.</p
    • …
    corecore