1,069 research outputs found

    Prognostic implications of left ventricular global longitudinal strain in heart failure patients with narrow QRS complex treated with cardiac resynchronization therapy: a subanalysis of the randomized EchoCRT trial

    Get PDF
    Aim: Left ventricular (LV) global longitudinal strain (GLS) reflects LV systolic function and correlates inversely with the extent of LV myocardial scar and fibrosis. The present subanalysis of the Echocardiography Guided CRT trial investigated the prognostic value of LV GLS in patients with narrow QRS complex. Methods and results: Left ventricular (LV) global longitudinal strain (GLS) was measured on the apical 2-, 4- and 3-chamber views using speckle tracking analysis. Measurement of baseline LV GLS was feasible in 755 patients (374 with cardiac resynchronization therapy (CRT)-ON and 381 with CRT-OFF). The median value of LV GLS in the overall population was 7.9%, interquartile range 6.2–10.1%. After a mean follow-up period of 19.4 months, 95 patients in the CRT-OFF group and 111 in the CRT-ON group reached the combined primary endpoint of all-cause mortality and heart failure hospitalization. Each 1% absolute unit decrease in LV GLS was independently associated with 11% increase in the risk to reach the primary endpoint (Hazard ratio 1.11; 95% confidence interval 95% 1.04–1.17, P < 0.001), after adjusting for ischaemic cardiomyopathy and randomization treatment among other clinically relevant variables. When categorizing patients according to quartiles of LV GLS, the primary endpoint occurred more frequently in patients in the lowest quartile (<6.2%) treated with CRT-ON vs. CRT-OFF (45.6% vs. 28.7%, P = 0.009) whereas, no differences were observed in patients with LV GLS ≥6.2% treated with CRT-OFF vs. CRT-ON (23.7% vs. 24.5%, respectively; P  = 0.62). Conclusion: Low LV GLS is associated with poor outcome in heart failure patients with QRS width <130 ms, independent of randomization to CRT or not. Importantly, in the group of patients with the lowest LV GLS quartile, CRT may have a detrimental effect on clinical outcomes

    Reply

    Get PDF

    “Pure” severe aortic stenosis without concomitant valvular heart diseases:echocardiographic and pathophysiological features

    Get PDF
    Purpose!#!In echocardiography the severity of aortic stenosis (AS) is defined by effective orifice area (EOA), mean pressure gradient (mPG!##!Methods and results!#!Patients (n = 306) with asymptomatic (n = 133) and symptomatic (n = 173) 'pure' severe AS (mean age 78 ± 9.5 years) defined by indexed EOA < 0.6 cm!##!Conclusion!#!In patients with 'pure' AS according to current guidelines the presence of combined LVH, DD and PAH as accepted pathophysiological sequelae of severe AS cannot be confirmed. Probably, the detection of these secondary cardiac alterations might improve the diagnostic algorithm to avoid overestimation of AS severity

    Echo-driven V-V optimization determines clinical improvement in non responders to cardiac resynchronization treatment

    Get PDF
    Echocardiography plays an integral role in the detection of mechanical dyssynchrony in patients with congestive heart failure and in predicting beneficial response to cardiac resynchronization treatment. In patients who derive sup-optimal benefit from biventricular pacing, optimization of atrioventricular delay post cardiac resynchronization treatment has been shown to improve cardiac output. Some recent reports suggest that sequential ventricular pacing may further improve cardiac output. The mechanism whereby sequential ventricular pacing improves cardiac output is likely improved inter and possibly intraventricular synchrony, however these speculations have not been confirmed. In this report we describe the beneficial effect of sequential V-V pacing on inter and intraventricular synchrony, cardiac output and mitral regurgitation severity as the mechanisms whereby sequential biventricular pacing improves cardiac output and functional class in 8 patients who had derived no benefit or had deteriorated after CRT. Online tissue Doppler imaging including tissue velocity imaging, tissue synchronization imaging and strain and strain rate imaging were used in addition to conventional pulsed wave and color Doppler during sequential biventricular pacemaker programming

    Dynamic three-dimensional echocardiography combined with semi-automated border detection offers advantages for assessment of resynchronization therapy

    Get PDF
    Simultaneous electrical stimulation of both ventricles in patients with interventricular conduction disturbance and advanced heart failure improves hemodynamics and results in increased exercise tolerance, quality of life. We have developed a novel technique for the assessment and optimization of resynchronization therapy. Our approach is based on transthoracic dynamic three-dimensional (3D) echocardiography and allows determination of the most delayed contraction site of the left ventricle (LV) together with global LV function data. Our initial results suggest that fast reconstruction of the LV is feasible for the selection of the optimal pacing site and allows identifying LV segments with dyssynchrony

    On the non-planar beta-deformed N=4 super-Yang-Mills theory

    Full text link
    The beta-deformation is one of the two superconformal deformations of the N=4 super-Yang-Mills theory. At the planar level it shares all of its properties except for supersymmetry, which is broken to the minimal amount. The tree-level amplitudes of this theory exhibit new features which depart from the commonly assumed properties of gauge theories with fields in the adjoint representation. We analyze in detail complete one-loop amplitudes and a nonplanar two-loop amplitude of this theory and show that, despite having only N=1 supersymmetry, two-loop amplitudes have a further-improved ultraviolet behavior. This phenomenon is a counterpart of a similar improvement previously observed in the double-trace amplitude of the N=4 super-Yang-Mills theory at three and four loop order and points to the existence of additional structure in both the deformed and undeformed theories.Comment: 39 pages, 8 figure

    Adiposity has differing associations with incident coronary heart disease and mortality in the Scottish population: cross-sectional surveys with follow-up

    Get PDF
    Objective: Investigation of the association of excess adiposity with three different outcomes: all-cause mortality, coronary heart disease (CHD) mortality and incident CHD. Design: Cross-sectional surveys linked to hospital admissions and death records. Subjects: 19 329 adults (aged 18–86 years) from a representative sample of the Scottish population. Measurements: Gender-stratified Cox proportional hazards models were used to estimate hazard ratios (HRs) for all-cause mortality, CHD mortality and incident CHD. Separate models incorporating the anthropometric measurements body mass index (BMI), waist circumference (WC) or waist–hip ratio (WHR) were created adjusted for age, year of survey, smoking status and alcohol consumption. Results: For both genders, BMI-defined obesity (greater than or equal to30 kg m−2) was not associated with either an increased risk of all-cause mortality or CHD mortality. However, there was an increased risk of incident CHD among the obese men (hazard ratio (HR)=1.78; 95% confidence interval=1.37–2.31) and obese women (HR=1.93; 95% confidence interval=1.44–2.59). There was a similar pattern for WC with regard to the three outcomes; for incident CHD, the HR=1.70 (1.35–2.14) for men and 1.71 (1.28–2.29) for women in the highest WC category (men greater than or equal to102 cm, women greater than or equal to88 cm), synonymous with abdominal obesity. For men, the highest category of WHR (greater than or equal to1.0) was associated with an increased risk of all-cause mortality (1.29; 1.04–1.60) and incident CHD (1.55; 1.19–2.01). Among women with a high WHR (greater than or equal to0.85) there was an increased risk of all outcomes: all-cause mortality (1.56; 1.26–1.94), CHD mortality (2.49; 1.36–4.56) and incident CHD (1.76; 1.31–2.38). Conclusions: In this study excess adiposity was associated with an increased risk of incident CHD but not necessarily death. One possibility is that modern medical intervention has contributed to improved survival of first CHD events. The future health burden of increased obesity levels may manifest as an increase in the prevalence of individuals living with CHD and its consequences

    The effect of QRS duration on cardiac resynchronization therapy in patients with a narrow QRS complex: a subgroup analysis of the EchoCRT trial

    Get PDF
    Aims In EchoCRT, a randomized trial evaluating the effect of cardiac resynchronization therapy (CRT) in patients with a QRS duration of <130 ms and echocardiographic evidence of left ventricular dyssynchrony, the primary outcome occurred more frequently in the CRT when compared with the control group. According to current heart failure guidelines, CRT is recommended in patients with a QRS duration of ≥120 ms. However, there is some ambiguity from clinical trial data regarding the benefit of patients with a QRS duration of 120-130 ms. Methods and results The main EchoCRT trial was prematurely terminated due to futility. For the current subgroup analysis we compared data for CRT-ON vs. -OFF in patients with QRS < 120 (n = 661) and QRS 120-130 ms (n = 139). On uni- and multivariable analyses, no significant interaction was observed between the two groups and randomized treatment for the primary or any of the secondary endpoints. On multivariable analysis, a higher risk for the primary endpoint was observed in patients with a QRS duration of 120-130 ms randomized to CRT-ON vs. CRT-OFF (hazard ratio 2.18, 95% CI 1.02-4.65; P = 0.044). However, no statistically significant interaction, compared with patients with QRS < 120 ms randomized to CRT-ON vs. CRT-OFF, was noted (P-interaction = 0.160). Conclusions In this pre-specified subgroup analysis of EchoCRT, no benefit of CRT was evident in patients with a QRS duration of 120-130 ms. These data further question the usefulness of CRT in this patient populatio

    Cardiac resynchronization therapy in patients with heart failure and narrow QRS complexes

    Get PDF
    Background: Cross correlation analysis (CCA) using tissue Doppler imaging has been shown to be associated with outcome after cardiac resynchronization therapy (CRT) in patients with heart failure (HF) with wide QRS. However, its significance in patients with narrow QRS treated with CRT is unknown. Objectives: The aim of the current study was to investigate the association of mechanical activation delay by CCA with study outcome in patients with HF enrolled in the EchoCRT trial. Methods: Baseline CCA could be performed from tissue Doppler imaging in the apical views in 807 of 809 (99.7%) enrolled patients, and 6-month follow-up could be performed in 610 of 635 (96%) patients with available echocardiograms. Patients with a pre-specified maximal activation delay ≥35 ms were considered to have significant delay. The study outcome was HF hospitalization or death. Results: Of 807 patients, 375 (46%) did not have delayed mechanical activation at baseline by CCA. Patients without delayed mechanical activation who were randomized to CRT-On compared with CRT-Off had an increased risk of poor outcome (hazard ratio: 1.70; 95% confidence interval: 1.13 to 2.55; p = 0.01) with a significant interaction term (p = 0.04) between delayed mechanical activation and device randomization for the endpoint. Among patients with paired baseline and follow-up data with no events before 6-month follow-up (n = 541), new-onset delayed mechanical activation in the CRT-On group showed a significant increase in unfavorable events (hazard ratio: 3.73; 95% confidence interval: 1.15 to 12.14; p = 0.03). Conclusions: In the EchoCRT population, absence of delayed mechanical activation by CCA was significantly associated with poor outcomes, possibly due to the onset of new delayed mechanical activation with CRT pacing. (Echocardiography Guided Cardiac Resynchronization Therapy [EchoCRT] Trial; NCT00683696)
    corecore