155 research outputs found

    Coronary artery bypass grafting: Part 2—optimizing outcomes and future prospects

    Get PDF
    Since first introduced in the mid-1960s, coronary artery bypass grafting (CABG) has become the standard of care for patients with coronary artery disease. Surprisingly, the fundamental surgical technique itself did not change much over time. Nevertheless, outcomes after CABG have dramatically improved over the first 50 years. Randomized trials comparing percutaneous coronary intervention (PCI) to CABG have shown converging outcomes for select patient populations, providing more evidence for wider use of PCI. It is increasingly important to focus on the optimization of the short- and long-term outcomes of CABG and to reduce the level of invasiveness of this procedure. This review provides an overview on how new techniques and widespread consideration of evolving strategies have the potential to optimize outcomes after CABG. Such developments include off-pump CABG, clampless/anaortic CABG, minimally invasive CABG with or without extending to hybrid procedures, arterial revascularization, endoscopic vein harvesting, intraprocedural epiaortic scanning, graft flow assessment, and improved secondary prevention measures. In addition, this review represents a framework for future studies by summarizing the areas that need more rigorous clinical (randomized) evaluatio

    A silent gigantic solitary fibrous tumor of the pleura: case report

    Get PDF
    Solitary fibrous tumor of the pleura is a rare mesenchymal tumor, representing less than 5% of all neoplasms associated with the pleura. A 57-year-old man had general malaise without chest symptoms for 1 month. A chest roentgenogram and computed tomography showed a giant mass in the left thorax. Although the tumor compressed the descending aorta and other mediastinal structures strongly, thereby shifting them to the right side, the patient had no symptoms except malaise. The tumor was successfully resected via two separate thoracotomies. The tumor was measured (20 cm × 19 cm × 15 cm) and weighed (2150 g). The tumor was histologically and immunohistochemically diagnosed as benign. Although SFT is benign, a long follow-up period is essential as even patients with complete resection are at risk of recurrence many years after surgery

    Causes and predictors of early mortality in patients treated with left ventricular assist device implantation in the European Registry of Mechanical Circulatory Support (EUROMACS)

    Get PDF
    Purpose: The aim of the study was to analyze early mortality after continuous-flow left ventricular assist device (LVAD) implantation which remains high. Methods: We analyzed consecutive (n = 2689) patients from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) undergoing continuous-flow LVAD implantation. The primary outcome was early (< 90 days) mortality. Secondary outcomes were differential causes of early post-operative death following LVAD implantation. Results: Univariable and multivariable analysis as well as regression analysis were used to examine determinants and differential causes of early (< 90 days) mortality after LVAD implantation. During the first 90 days, 2160 (80%) patients were alive with ongoing LVAD support, 40(2%) patients underwent heart transplantation, and 487(18%) deceased. The main causes of early death were MOF (36%), sepsis (28%), cardiopulmonary failure (CPF; 10%), CVA (9%), and right-sided heart failure (RHF, 8%). Furthermore, MOF and sepsis are 70% of causes of death in the first week. Independent clinical predictors of early death were age, female sex, INTERMACS profile 1 to 3, and ECMO. Laboratory predictors included elevated serum creatinine, total bilirubin, lactate, and low hemoglobin. Furthermore, hemodynamic predictors included elevated RA-to-PCWP ratio, pulmonary vascular resistance, and low systemic vascular resistance. Longer total implantation time was also independent predictor of early mortality. A simple model of 12 variables predicts early mortality following LVAD implantation with a good discriminative power with area under the curve of 0.75. Conclusions: In the EUROMACS registry, approximately one out of five patients die within 90 days after LVAD implantation. Early mortality is primarily dominated by multiorgan failure followed by sepsis. A simple model identifies important parameters which are associated with early mortality following LVAD implantation

    Impact of extra-corporeal life support (ECLS) cannulation strategy on outcome after durable mechanical circulation support system implantation on behalf of durable MCS after ECLS Study Group

    Get PDF
    Background: The literature on outcomes of patients requiring durable mechanical circulatory support (MCS) after extra-corporeal life support (ECLS) is limited. The aim of this study was to investigate the impact of preoperative ECLS cannulation on postoperative outcome after durable MCS implantation. Methods: The durable MCS after ECLS registry is a multicenter retrospective study that gathered data on consecutive patients who underwent durable MCS implantation after ECLS between January 2010 and August 2018 in eleven high volume European centers. Patients who underwent the implantation of total artificial heart, pulsatile pumps, or first-generation pumps after ECLS were excluded from the analysis. The remaining patients were divided into two groups; central ECLS group (cECLS) and peripheral ECLS group (pECLS). A 1:1 propensity score analysis was performed to identify two matched groups. The outcome of these two groups was compared. Results: A total of 531 durable MCS after ECLS were implanted during this period. The ECLS cannulation site was peripheral in 87% (n=462) and central in 13% (n=69) of the patients. After excluding pulsatile pumps and total artificial heart patients, a total of 494 patients remained (pECLS =434 patients, cECLS =60 patients). A 1:1 propensity score analysis resulted in 2 matched groups (each 55 patients) with median age of 54 years (48-60 years) in cECLS group and 54 years (43-60 years) in pECLS group. HeartWare HVAD (Medtronic, Minneapolis, MN) was implanted in the majority of the patients (cECLS =71% vs. pECLS =76%, P=0.67). All postoperative morbidities were comparable between the groups. The thirty-day, one year and long-term survival was comparable between the groups (P=0.73). Conclusions: The cannulation strategy of ECLS appears to have no impact on the post-operative outcome after durable MCS implantation

    Acute kidney injury following transcatheter aortic valve implantation: predictive factors, prognostic value, and comparison with surgical aortic valve replacement

    Get PDF
    Aims: Very few data exist on the occurrence of acute kidney injury (AKI) associated with transcatheter aortic valve implantation (TAVI). The objectives of the present study were (i) to determine the incidence, predictive factors, and prognostic value of AKI following TAVI, and (ii) to compare the occurrence of AKI in TAVI vs. surgical aortic valve replacement (SAVR) in patients with pre-procedural chronic kidney disease (CKD). Methods and results: A total of 213 patients (mean age 82 ± 8 years) undergoing TAVI for the treatment of severe aortic stenosis were included in the study. Acute kidney injury was defined as a reduction of >25% in estimated glomerular filtration rate (eGFR) within 48 h following the procedure or the need for haemodialysis during index hospitalization. Those patients with pre-procedural CKD (eGFR <60 mL/min/1.73 m2, n = 119) were compared with 104 contemporary patients with CKD who underwent isolated SAVR. The incidence of AKI following TAVI was 11.7%, with 1.4% of the patients requiring haemodialysis. Predictive factors of AKI were hypertension (OR: 4.66; 95% CI: 1.04–20.87), chronic obstructive pulmonary disease (OR: 2.64, 95% CI: 1.10–6.36), and peri-operative blood transfusion (OR: 3.47, 95% CI: 1.30–9.29). Twenty-one patients (9.8%) died during index hospitalization, and the logistic EuroSCORE (OR: 1.03 for each increase of 1%; 95% CI: 1.01–1.06) and occurrence of AKI (OR: 4.14, 95% CI: 1.42–12.13) were identified as independent predictors of postoperative mortality. Patients with CKD who underwent TAVI were older, had a higher logistic EuroSCORE and lower pre-procedural eGFR values compared with those who underwent SAVR (P < 0.0001 for all). The incidence of AKI was lower (P = 0.001; P = 0.014 after propensity score adjustment) in CKD patients who underwent TAVI (9.2%, need for haemodialysis: 2.5%) compared with those who underwent SAVR (25.9%, need for haemodialysis: 8.7%). Conclusion: Acute kidney injury occurred in 11.7% of the patients following TAVI and was associated with a greater than four-fold increase in the risk of postoperative mortality. Hypertension, chronic obstructive pulmonary disease, and blood transfusion were predictive factors of AKI. In those patients with pre-procedural CKD, TAVI was associated with a significant reduction of AKI compared with SAVR

    Impact of a surgical approach for implantation of durable left ventricular assist devices in patients on extracorporeal life support

    Get PDF
    Background The aim of this study was to evaluate the impact of the surgical approach on the postoperative outcome in patients who underwent left ventricular assist device (LVAD) implantation after having received veno-arterial extracorporeal life support (va-ECLS) using data from a European registry (ECLS-VAD). Five hundred and thirty-one patients were included. Methods A propensity score-adjusted outcome analysis was performed, resulting in 324 patients in the full sternotomy (FS) group and 39 in the less invasive surgery (LIS) group. Results The surgery lasted in median 236 min in the FS group versus 263 min in the LIS group (p = 0.289). The median chest tube output during the first 24 h was similar in both groups. Patients who underwent implantation with an FS required more blood products during the first 24 postoperative hours (median 16 vs. 12, p = 0.033). The incidence of revision due to bleeding was also higher (35.5 vs. 15.4%, p = 0.016). A temporary postoperative right ventricular assist device was necessary in 45.1 (FS) versus 23.1% (LIS) of patients, respectively (p = 0.067). No stroke occurred in the LIS group during the first 30 days after surgery (7.4% in the FS group). The incidence of stroke and of renal, hepatic, and respiratory failure during the follow-up was similar in both groups. The 30-day and one-year survival were similar in both groups. Conclusion LIS for implantation of a durable LVAD in patients on va-ECLS implanted for cardiogenic shock is associated with less revision due to bleeding, less administration of blood products and absence of perioperative stroke, with no impact on survival

    Concomitant ablation of atrial fibrillation in octogenarians: an observational study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiac surgery is increasingly required in octogenarians. These patients frequently present atrial fibrillation (AF), a significant factor for stroke and premature death. During the last decade, AF ablation has become an effective procedure in cardiac surgery. Because the results of concomitant AF ablation in octogenarians undergoing cardiac surgery are still not clear, we evaluated the outcome in these patients.</p> <p>Methods</p> <p>Among 200 patients undergoing concomitant AF ablation (87% persistent AF), 28 patients were ≥ 80 years (82 ± 2.4 years). The outcome was analysed by prospective follow up after 3, 6, 12 months and annually thereafter. Freedom from AF was calculated according to the Kaplan-Meier method.</p> <p>Results</p> <p>Octogenarians were similar to controls regarding AF duration (48 ± 63.2 versus 63 ± 86.3 months, n.s.) and left atrial diameter (49 ± 6.1 versus 49 ± 8.8 mm, n.s.), but differed in EuroSCORE (17.3 ± 10.93 versus 7.4 ± 7.31%, p < 0.001), prevalence of paroxysmal AF (25.0 versus 11.0%, p = 0.042) and aortic valve disease (67.8 versus 28.5%, p < 0.001). ICU stay (8 ± 16.9 versus 4 ± 7.2 days, p = 0.027), hospital stay (20 ± 23.9 versus 14 ± 30.8 days, p < 0.05), and 30-d-mortality (14.3 versus 4.6%, p = 0.046) were increased. After 12 ± 6.1 months of follow-up (95% complete), 14 octogenarians (82%) and 101 controls (68%, n.s.) were in sinus rhythm; 59% without antiarrhythmic drugs in either group (n.s.). Sinus rhythm restoration was associated with improved NYHA functional class and renormalization of left atrial size. Cumulative freedom from AF demonstrated no difference between groups. Late mortality was higher in octogenarians (16.7 versus 6.1%, p = 0.065).</p> <p>Conclusion</p> <p>Sinus rhythm restoration rate and functional improvement are satisfactory in octogenarians undergoing concomitant AF ablation. Hence, despite an increased perioperative risk, this procedure should be considered even in advanced age.</p

    An assessment of irrigated rice cultivation with different crop establishment practices in Vietnam

    Get PDF
    Overuse of seed and chemical inputs is a major constraint for sustainable rice production in Vietnam. In this study, two seasons of field trials were conducted to compare different crop establishment practices for rice production in the Mekong River Delta using environmental and economic sustainability performance indicators. The indicators including energy efficiency, agronomic use efficiency, net income, and greenhouse gas emissions (GHGEs) were quantified based on four treatments including manual broadcast-seeding, blower seeding, drum seeding, and mechanized transplanting. Across the four treatments, yields ranged from 7.3–7.5 Mg ha−1 and 6.2–6.8 Mg ha−1 in the Winter-Spring (WS) and Summer-Autumn (SA) seasons, respectively. In comparison with direct seeding methods, mechanized transplanting decreased the seed rate by 40%. It also led to a 30–40% reduction in pesticide use during the main crop season (WS). Mechanized transplanting required higher inputs, including machine depreciation and fuel consumption, but its net energy balance, net income and GHGE were at a similar level as the other non-mechanized planting practices. Mechanized transplanting is a technology package that should be promoted to improve the economic and environmental sustainability of lowland rice cultivation in the Mekong River Delta of Vietnam
    corecore