42 research outputs found

    Anterior-inferior plating of middle-third fractures of the clavicle

    Get PDF
    © The Author(s) 2009. This article is published with open access at Springerlink.com Introduction Various techniques have been reported for the treatment of middle-third clavicle (collar bone) fractures. This prospective study was conducted to evaluate the results of anterior-inferior plating using a 3.5-mm reconstruction plate for the treatment of middle-third clavicle fractures

    Three-dimensional localization of nanoscale battery reactions using soft X-ray tomography.

    Get PDF
    Battery function is determined by the efficiency and reversibility of the electrochemical phase transformations at solid electrodes. The microscopic tools available to study the chemical states of matter with the required spatial resolution and chemical specificity are intrinsically limited when studying complex architectures by their reliance on two-dimensional projections of thick material. Here, we report the development of soft X-ray ptychographic tomography, which resolves chemical states in three dimensions at 11 nm spatial resolution. We study an ensemble of nano-plates of lithium iron phosphate extracted from a battery electrode at 50% state of charge. Using a set of nanoscale tomograms, we quantify the electrochemical state and resolve phase boundaries throughout the volume of individual nanoparticles. These observations reveal multiple reaction points, intra-particle heterogeneity, and size effects that highlight the importance of multi-dimensional analytical tools in providing novel insight to the design of the next generation of high-performance devices

    Efeito de reguladores de crescimento sobre os teores de ácido ascórbico e carboidratos solúveis de morango (Fragaria hybridus)

    Get PDF
    Several growth regulators were sprayed on strawberry plants: SADH (5000 ppm), CCC (2000 ppm), IAA (10 ppm, 3 times), GA 10 ppm, 3 times) and GA (550 ppm), Ascorbic acid, dry weight and soluble carbohydrates contents of fruits were determined. Statistically differences were not observed between treatments and control. Dry weight varied from 7.62 to 9.53%. Ascorbic acid content varied from 35.88 to 71.81 mg/100 g on fresh weight basis. Mean values of soluble carbohydrates, in grams/100 g on fresh weight basis, were total (5.58), sucrose (1.01), glucose (1.63) and frutose (1.54).Foram feitas aplicações dos seguintes reguladores de crescimento em morango (Fragarm hybridus): SADH a 5000 ppm, CCC a 2000 ppm, ATA a 10 ppm (3 aplicações), ácido giberélico a 10 ppm (3 aplicações) e 550 ppm. Análises de peso seco, ácido ascórbico e carboidratos solúveis dos frutos foram efetuadas a fim de se estudar o efeito desses reguladores de crescimento. Não foram detectadas diferenças significativas entre os diversas tratamentos e o controle. O peso seco variou de 7,62 a 9,53%. O conteúdo de ácido ascórbico variou de 35,88 a 71,81 mg/100 g de peso fresco. Os teores médios de carboidratos solúveis, expresso em g/100 g peso fresco, foram: totais (5,58), sacarose (1,01), glucose (1,63) e frutose (1,54)

    Residual stress mapping by micro X-ray diffraction: Application to the study of thin film buckling

    No full text
    Thin films deposited by Physical Vapour Deposition techniques on substrates generally exhibit large residual stresses which may be responsible of spontaneous detachment of the film from its substrate and in the case of compressive stresses, thin film buckling. Although these effects are undesirable for future applications, one may take benefit of it for thin film mechanical properties investigation. Since the 80's, a lot of theoretical works have been done to develop mechanical models with the aim to get a better understanding of driven mechanisms giving rise to this phenomenon and thus to propose solutions to avoid such problems. Nevertheless, only a few experimental works have been done on this subject to support these theoretical results and nothing concerning local stress/strain measurement mainly because of the small dimension of the buckling (few tenth mm). This paper deals with the application of micro beam x-ray diffraction available on synchrotron radiation sources for stress/strain mapping analysis of gold thin film buckling
    corecore