23 research outputs found
Improving implant training for physicians and their teams in under-represented regions
The burden of cardiovascular disease is increasing globally, with low- and middle-income countries (LMICs) absorbing most of the burden while lacking the necessary healthcare infrastructure to combat the increase. In particular, the disparity in pacemaker implants between high-income countries and LMICs is glaring, partially spurned by reduced numbers of physicians and supporting staff who are trained in pacemaker implant technique. Herein, we will discuss current pacemaker implant training models, outline training frameworks that can be applied to underserved regions, and review adjunctive training techniques that can help supplement traditional training models in LMICs
Percutaneous right atrial pacemaker lead repositioning using a regular deflectable ablation catheter
Impact of respiration gating on image integration guided atrial fibrillation ablation
BACKGROUND: Radiofrequency (RF) catheter ablation guided by electroanatomic mapping systems is an effective therapy for atrial fibrillation. However, it may be affected by respiration movements. The aim of this study was to determine the impact of respiratory gating on procedural parameters in patients undergoing catheter ablation of atrial fibrillation (AF). METHODS AND RESULTS: One-hundred forty consecutive patients undergoing pulmonary vein isolation were admitted to study. Respiratory gating module (AccuResp algorithm, Carto3, Biosense Webster) was enabled in 70 patients and disabled in 70 patients during procedures. Successful pulmonary vein isolation and sinus rhythm were obtained in all patients. A significant reduction in total procedure times [median 77, interquartile range (IQR 66-95) min vs median 82 (IQR 72-104) min, p < 0.05] and fluoroscopy times [median 14 (IQR 9-17) min vs median 16 (IQR 12-22) min, p < 0.05] were observed in the respiratory gated group. Although ablation times (duration between the first and last ablation) were significantly shorter in respiratory gated group [median 37 (IQR 32-53) min vs median 48 (IQR 39-65) min, p < 0.05], total RF application durations were not different between two groups [median 1,554 (IQR 1,213-2,196) s vs median 1,802 (IQR 1,344-2,448) s, p = 0.11]. Difference in electroanatomical map reconstruction times was not significant [median 14 (IQR 12-16) min in gated group vs median 13 (IQR 10-18) min in nongated group, p = 0.19]. CONCLUSION: Respiratory gating significantly improves fluoroscopy and ablation times during electroanatomic mapping guided AF ablation. Respiratory gated maps may provide uninterrupted continuous ablation applications. Furthermore, using automatic respiratory gating module does not prolong mapping times
Effect of cardiac resynchronization therapy with implantable cardioverter defibrillator versus cardiac resynchronization therapy with pacemaker on mortality in heart failure patients: results of a high-volume, single-centre experience.
AIMS: There are limited and contradictory data on the effects of CRT with implantable cardioverter defibrillator (CRT-D) on mortality as compared with CRT with pacemaker (CRT-P). METHODS AND RESULTS: We evaluated the long-term outcome of patients implanted with a CRT-D or CRT-P device in our high-volume single-centre experience. Data on all-cause mortality were derived from clinic visits and the Hungarian National Healthcare Fund Death Registry. Kaplan-Meier survival analyses and multivariate Cox regression models were used to evaluate all-cause mortality in patients with CRT-D vs. CRT-P, stratified by the aetiology of cardiomyopathy. From 2000 to 2011, 1122 CRT devices, 693 CRT-P (LVEF 28.2 +/- 7.4%) and 429 CRT-D (LVEF 27.6 +/- 6.4%), were implanted at our centre. During the median follow-up of 28 months, 379 patients died from any cause, 250 patients (36%) with an implanted CRT-P and 129 patients (30%) with an implanted CRT-D. There was no evidence of mortality benefit in patients implanted with a CRT-D compared with a CRT-P in the total cohort [hazard ratio (HR) 0.98, 95% confidence interval (CI) 0.73-1.32, P = 0.884]. In patients with ischaemic cardiomyopathy, CRT-D treatment was associated with a significant 30% risk reduction in all-cause mortality compared with an implanted CRT-P (HR 0.70, 95% CI 0.51-0.97, P = 0.03). In non-ischaemic patients, there was no mortality benefit of CRT-D over CRT-P (HR 0.98, 95% CI 0.73-1.32, P = 0.894, interaction P-value = 0.15). CONCLUSIONS: In heart failure patients with ischaemic cardiomyopathy, CRT-D was associated with a mortality benefit compared with CRT-P, but no benefit of CRT-D over CRT-P in mortality was observed in non-ischaemic cardiomyopathy
Impact of Congenital Heart Disease On Higher Education
World Congress of Cardiology Scientific Sessions -- JUN 16-19, 2010 -- Beijing, PEOPLES R CHINAWOS: 000279801702444
Multipoint pacing controlled the electrical storm induced by cardiac resynchronization therapy
WOS: 000457581300009PubMed ID: 2986886
Percutaneous right atrial pacemaker lead repositioning using a regular deflectable ablation catheter
Percutaneous right atrial pacemaker lead repositioning using a regular deflectable ablation catheter
International audienc