3 research outputs found
Healthcare Utilization and Quality of Life Improvement after Ablation for Paroxysmal AF in Younger and Older Patients
Background
Atrial fibrillation (AF) prevalence increases significantly with age. Little is known about the effect of AF ablation on quality of life and healthcare utilization in the elderly. The objective of this study was to quantify the healthcare utilization and quality of life benefits of catheter ablation for AF, for patients ≥65 years compared to patients <65 years.
Methods
Two multicenter U.S. registry studies enrolled patients with paroxysmal AF. Baseline characteristics and acute outcomes were collected for 736 patients receiving catheter ablation with the Navistar® ThermoCool® SF Catheter (Biosense Webster, Inc., Diamond Bar, CA, USA). Healthcare utilization and quality of life outcomes were collected through 1 year postablation for 508 patients.
Results
The rates of acute pulmonary vein isolation were high and similar between patients ≥65 years and <65 years (97.5% vs 95.8%, P = 0.2130). Length of stay for the index procedure was similar between age groups with 82.2% of the older group and 83.2% of the younger group having one-day hospitalization. Disease-specific quality of life instrument scores improved significantly and similarly for older and younger patients at 1 year postablation, compared to baseline. AF-related hospitalizations and emergency department visits were similar or lower in older patients compared to younger patients, as reported at 1 year postablation.
Conclusion
For older patients undergoing catheter ablation for paroxysmal AF, healthcare utilization parameters were lower or not significantly different than for younger patients, and quality of life outcomes were similarly improved. These findings support the use of catheter ablation as a treatment option in older patients with paroxysmal AF
Leadless left ventricular stimulation with WiSE-CRT system - Initial experience and results from phase I of SOLVE-CRT study (nonrandomized, roll-in phase)
BACKGROUND: Left ventricular (LV) endocardial pacing is a promising method to deliver cardiac resynchronization therapy (CRT). WiSE-CRT is a wireless LV endocardial pacing system, and delivers ultrasonic energy to an LV electrode.
OBJECTIVE: The purpose of this study was to present short-term outcomes with the WiSE-CRT system in centers with no prior implanting experience.
METHODS: Data were prospectively collected from 19 centers where WiSE-CRT systems were implanted during the roll-in phase of the SOLVE-CRT trial. Patients were followed at 1, 3, and 6 months, including transthoracic echo (TTE) at 6 months.
RESULTS: The WiSE-CRT was successfully implanted in all 31 attempted cases, and 30 patients completed the 6-month follow-up. One patient underwent heart transplantation 1 month after implantation, and was excluded. Fourteen (46.7%) patients demonstrated ≥1 NYHA class improvement. TTE data were available in 29 patients. LV ejection fraction, LV end-systolic volume, and LV end-diastolic volume improved from 28.3% ± 6.7% to 33.5% ± 6.9% (P \u3c .001), 134.9 ± 51.3 mL to 111.1 ± 40.3 mL (P = .0004), and 185.4 ± 58.8 mL to 164.9 ± 50.6 mL (P = .0017), respectively. There were 3 (9.7%) device-related type 1 complications: 1 insufficient LV pacing, 1 embolization of an unanchored LV electrode, and 1 skin infection.
CONCLUSIONS: We demonstrated a high success rate of LV endocardial electrode placement in centers with no prior implanting experience. Favorable clinical responses in heart failure symptoms and significant LV reverse remodeling were noted