8 research outputs found

    OPTH-75297-a-single-center-evaluation-of-retaine----ophthalmic-emulsion

    No full text
    Clinical Ophthalmology Dovepress submit your manuscript | www.dovepress.com Dovepress 235 O r i g i n a l r e s e a r C h open access to scientific and medical research Abstract: A single-center, open-label study consisting of two visits over the course of approximately 2 weeks was conducted to evaluate the efficacy of Retaine™ ophthalmic emulsion in improving the signs and symptoms of dry eye. Forty-two subjects were enrolled and received 1-2 drops twice daily of Retaine™ beginning at the first visit (day 1) and ending at the second visit. Subjects were instructed to complete a symptomatology diary twice daily prior to drop instillation through the morning of the second visit. Ocular sign and symptom assessments, visual acuity procedures, and comfort assessments were conducted during both visits. A statistically significant reduction was observed in mean breakup area on the second visit between the predose time and the postdose time (P=0.026). On the second visit, subjects had significantly less corneal fluorescein staining in the superior (P=0.002), central (P=0.017), corneal sum (P=0.011), and all ocular regions combined (P=0.038) than on the first visit. On the second visit, statistically significant reductions in dryness (P0.001), grittiness (P=0.0217), ocular discomfort (P=0.0017), and all symptoms (P0.001) were also seen as measured by the Ora Calibra™ Ocular Discomfort and 4-Symptom Questionnaire (0-5 scale). Subjects reported a statistically significant improvement in their abilities to work with a computer at night (P=0.044). Mean drop comfort scores ranged from 1.29-1.81 on the Ora Calibra™ 0-10 Drop Comfort Scale, on which 0 is very comfortable and 10 is very uncomfortable. Retaine™ demonstrates promising results as a novel artificial tear option for individuals suffering from dry eye. The unique mechanism of action of Retaine™ provides enhanced comfort and improves the quality of life of dry eye subjects while reducing the ocular signs of dry eye

    An evaluation of Retaine™ ophthalmic emulsion in the management of tear film stability and ocular surface staining in patients diagnosed with dry eye

    No full text
    George Ousler III,1 Douglas K Devries,2 Paul M Karpecki,3 Joseph B Ciolino41Ora, Inc, Andover, MA, USA; 2Eye Care Associates of Nevada, Sparks, NV, USA; 3Koffler Vision Group, Lexington, KY, USA; 4Massachusetts Eye and Ear, Boston, MA, USAAbstract: A single-center, open-label study consisting of two visits over the course of approximately 2 weeks was conducted to evaluate the efficacy of Retaine™ ophthalmic emulsion in improving the signs and symptoms of dry eye. Forty-two subjects were enrolled and received 1–2 drops twice daily of Retaine™ beginning at the first visit (day 1) and ending at the second visit. Subjects were instructed to complete a symptomatology diary twice daily prior to drop instillation through the morning of the second visit. Ocular sign and symptom assessments, visual acuity procedures, and comfort assessments were conducted during both visits. A statistically significant reduction was observed in mean breakup area on the second visit between the predose time and the postdose time (P=0.026). On the second visit, subjects had significantly less corneal fluorescein staining in the superior (P=0.002), central (P=0.017), corneal sum (P=0.011), and all ocular regions combined (P=0.038) than on the first visit. On the second visit, statistically significant reductions in dryness (P<0.001), grittiness (P=0.0217), ocular discomfort (P=0.0017), and all symptoms (P<0.001) were also seen as measured by the Ora Calibra™ Ocular Discomfort and 4-Symptom Questionnaire (0–5 scale). Subjects reported a statistically significant improvement in their abilities to work with a computer at night (P=0.044). Mean drop comfort scores ranged from 1.29–1.81 on the Ora Calibra™ 0–10 Drop Comfort Scale, on which 0 is very comfortable and 10 is very uncomfortable. Retaine™ demonstrates promising results as a novel artificial tear option for individuals suffering from dry eye. The unique mechanism of action of Retaine™ provides enhanced comfort and improves the quality of life of dry eye subjects while reducing the ocular signs of dry eye.Keywords: artificial tears, dry eye syndrome, quality of life, cationic, lipid emulsion, mean breakup are

    Investigation of extended blinks and interblink intervals in subjects with and without dry eye

    No full text
    John D Rodriguez,1 George W Ousler III,1 Patrick R Johnston,1 Keith Lane,1 Mark B Abelson1,21Ora, Inc, Andover, MA, 2Schepens Eye Research Institute and Harvard Medical School, Boston, MA, USABackground: The purpose of this study was to investigate the occurrence and duration of extended blinks ≥ 70 msec and their associated interblink intervals in normal subjects and in subjects with mild to moderate dry eye.Methods: This single-center, prospective, double-blind study included 11 subjects with dry eye and eight subjects with normal eyes. Extended blinks were defined as lid closure in at least two successive video frames (≥ 70 msec). Digital video imaging of each subject's eyes was recorded while the subject viewed a 10-minute documentary. The subjects did not know that blink was the outcome being measured. Following capture, the videos were manually analyzed in a masked fashion for the occurrence of extended blinks. The length of the interblink interval (ie, time between blinks) before and after these extended blinks (the interblink interval ratio) was calculated, as well as differences in lid contact times.Results: The dry eye group had a median extended blink duration which was 2.53 times longer than that of the normal group. For subjects with dry eye, interblink intervals post-extended blink were significantly longer than interblink intervals pre-extended blink (P < 0.001). Interblink intervals did not lengthen significantly in normal subjects. In both groups, the duration of the extended blink was significantly (P = 0.001) and positively correlated with interblink interval ratio (post-extended to pre-extended blink interblink interval), such that for each doubling of extended blink duration, the interblink interval ratio increased by 10%. Blinks longer than one second in duration occurred almost exclusively in subjects with dry eye.Conclusion: This study reports three central findings: blink duration tended to be longer in subjects with dry eye; a lengthening of the interblink interval after an extended blink occurred in subjects with dry eye but not in those without dry eye; and a longer blink duration was associated with a significantly increased interblink interval ratio in all subjects.Keywords: dry eye, interblink intervals, visual function, visual tasks, diagnostic mode

    Automated grading system for evaluation of ocular redness associated with dry eye

    No full text
    John D Rodriguez,1 Patrick R Johnston,1 George W Ousler III,1 Lisa M Smith,1 Mark B Abelson1,21Ora, Inc, Andover, MA, USA; 2Department of Ophthalmology, Harvard Medical School, Boston, MA, USABackground: We have observed that dry eye redness is characterized by a prominence of fine horizontal conjunctival vessels in the exposed ocular surface of the interpalpebral fissure, and have incorporated this feature into the grading of redness in clinical studies of dry eye.Aim: To develop an automated method of grading dry eye-associated ocular redness in order to expand on the clinical grading system currently used.Methods: Ninety nine images from 26 dry eye subjects were evaluated by five graders using a 0–4 (in 0.5 increments) dry eye redness (Ora CalibraTM Dry Eye Redness Scale [OCDER]) scale. For the automated method, the Opencv computer vision library was used to develop software for calculating redness and horizontal conjunctival vessels (noted as "horizontality"). From original photograph, the region of interest (ROI) was selected manually using the open source ImageJ software. Total average redness intensity (Com-Red) was calculated as a single channel 8-bit image as R − 0.83G − 0.17B, where R, G and B were the respective intensities of the red, green and blue channels. The location of vessels was detected by normalizing the blue channel and selecting pixels with an intensity of less than 97% of the mean. The horizontal component (Com-Hor) was calculated by the first order Sobel derivative in the vertical direction and the score was calculated as the average blue channel image intensity of this vertical derivative. Pearson correlation coefficients, accuracy and concordance correlation coefficients (CCC) were calculated after regression and standardized regression of the dataset.Results: The agreement (both Pearson's and CCC) among investigators using the OCDER scale was 0.67, while the agreement of investigator to computer was 0.76. A multiple regression using both redness and horizontality improved the agreement CCC from 0.66 and 0.69 to 0.76, demonstrating the contribution of vessel geometry to the overall grade. Computer analysis of a given image has 100% repeatability and zero variability from session to session.Conclusion: This objective means of grading ocular redness in a unified fashion has potential significance as a new clinical endpoint. In comparisons between computer and investigator, computer grading proved to be more reliable than another investigator using the OCDER scale. The best fitting model based on the present sample, and usable for future studies, was C4 = –12.24 + 2.12C2HOR + 0.88C2RED :C4 is the predicted investigator grade, and C2HOR and C2REDare logarithmic transformations of the computer calculated parameters COM-Hor and COM-Red. Considering the superior repeatability, computer automated grading might be preferable to investigator grading in multicentered dry eye studies in which the subtle differences in redness incurred by treatment have been historically difficult to define.Keywords: conjunctival diseases, classification, diagnosis, humans, hyperemia, image processing, computer-assisted, observer variation, keratoconjunctivitis sicc

    The IMPACT study: a prospective evaluation of the effects of cyclosporine ophthalmic emulsion 0.05% on ocular surface staining and visual performance in patients with dry eye

    No full text
    Karl G Stonecipher,1,2 Gail L Torkildsen,3 George W Ousler III,4 Scot Morris,5 Linda Villanueva,6 David A Hollander6 1Department of Ophthalmology, University of North Carolina, Chapel Hill, 2TLC Laser Eye Centers, Greensboro, NC, 3Andover Eye Associates, 4Ora, Inc., Andover, MA, 5Eye Consultants of Colorado, Conifer, CO, 6Allergan plc, Irvine, CA, USA Objective: The aim of this study was to evaluate the effects of cyclosporine ophthalmic emulsion 0.05% on ocular surface staining and visual performance in patients with dry eye.Methods: This was a single-center, 6-month, open-label, Phase IV study. Patients with bilateral dry eye disease and a symptom score of ≥2 on the Ocular Discomfort and 4-Symptom Questionnaire, an Ocular Surface Disease Index score of >12, at least one eye with Schirmer’s score <10 mm/5 minutes, and central corneal staining graded as ≥2 on the Ora Calibra™ Corneal and Conjunctival Staining Scale were enrolled. Cyclosporine ophthalmic emulsion 0.05% (Restasis®) was instilled twice daily in each eye. The primary efficacy endpoints were ocular surface staining and visual function at 6 months. Secondary outcome measures included Schirmer’s test, tear film breakup time, symptoms, and adverse events.Results: A total of 40 patients with the mean age of 59.4 years (range, 40–78 years) were enrolled; 35 (87.5%) were female and 37 (92.5%) completed the study. At 6 months, inferior corneal, central corneal, total corneal, and total ocular surface fluorescein staining were significantly improved from baseline in both eyes (P<0.001). Patient responses on the Ocular Surface Disease Index showed significant improvement in blurred vision and visual function related to reading, driving at night, working with a computer or bank machine, and watching television (P≤0.041). At 6 months, 35.1% of patients achieved ≥5 mm improvement and 18.9% achieved ≥10 mm improvement in the average eye Schirmer score. Mean tear film breakup time improved by >50% in both eyes (P<0.001). Patients reported significant improvement in ocular discomfort and dry eye symptoms (P<0.001). No patients discontinued treatment because of stinging or any other ocular adverse event.Conclusion: Dry eye patients with difficulties with day-to-day visual function demonstrated improvement in both signs and symptoms of dry eye and reported improved visual function after 6 months of treatment with cyclosporine ophthalmic emulsion 0.05%. Keywords: corneal staining, dry eye disease, Ocular Surface Disease Index, ocular surface staining, visual function, clinical tria

    32 Oog

    No full text
    corecore