6 research outputs found
Management of rhinosinusitis in children
The authors provide definitions for the different forms of pediatric rhinosinusitis, with an enumeration of the main symptoms and signs. They also provide the indications for CT scan examination and microbiological investigations. In addition, they emphasize the importance of concomitant systemic disease, such as allergy and immunological disorders. The adequate medical management, which is mandatory before any surgery, is considered and discussed, and the indications for surgery are provided. Copyright (C) 1999 Elsevier Science Ireland Ltd.SCOPUS: cp.jinfo:eu-repo/semantics/publishe
Does Reinforcement Learning Improve Outcomes for Critically Ill Patients?:A Systematic Review and Level-of-Readiness Assessment
OBJECTIVE: Reinforcement learning (RL) is a machine learning technique uniquely effective at sequential decision-making, which makes it potentially relevant to ICU treatment challenges. We set out to systematically review, assess level-of-readiness and meta-analyze the effect of RL on outcomes for critically ill patients.DATA SOURCES: A systematic search was performed in PubMed, Embase.com, Clarivate Analytics/Web of Science Core Collection, Elsevier/SCOPUS and the Institute of Electrical and Electronics Engineers Xplore Digital Library from inception to March 25, 2022, with subsequent citation tracking.DATA EXTRACTION: Journal articles that used an RL technique in an ICU population and reported on patient health-related outcomes were included for full analysis. Conference papers were included for level-of-readiness assessment only. Descriptive statistics, characteristics of the models, outcome compared with clinician's policy and level-of-readiness were collected. RL-health risk of bias and applicability assessment was performed.DATA SYNTHESIS: A total of 1,033 articles were screened, of which 18 journal articles and 18 conference papers, were included. Thirty of those were prototyping or modeling articles and six were validation articles. All articles reported RL algorithms to outperform clinical decision-making by ICU professionals, but only in retrospective data. The modeling techniques for the state-space, action-space, reward function, RL model training, and evaluation varied widely. The risk of bias was high in all articles, mainly due to the evaluation procedure.CONCLUSION: In this first systematic review on the application of RL in intensive care medicine we found no studies that demonstrated improved patient outcomes from RL-based technologies. All studies reported that RL-agent policies outperformed clinician policies, but such assessments were all based on retrospective off-policy evaluation.</p
Biofilm formation on stainless steel and gold wires for bonded retainers in vitro and in vivo and their susceptibility to oral antimicrobials
<p>Bonded retainers are used in orthodontics to maintain treatment result. Retention wires are prone to biofilm formation and cause gingival recession, bleeding on probing and increased pocket depths near bonded retainers. In this study, we compare in vitro and in vivo biofilm formation on different wires used for bonded retainers and the susceptibility of in vitro biofilms to oral antimicrobials.</p><p>Orthodontic wires were exposed to saliva, and in vitro biofilm formation was evaluated using plate counting and live/dead staining, together with effects of exposure to toothpaste slurry alone or followed by antimicrobial mouthrinse application. Wires were also placed intra-orally for 72 h in human volunteers and undisturbed biofilm formation was compared by plate counting and live/dead staining, as well as by denaturing gradient gel electrophoresis for compositional differences in biofilms.</p><p>Single-strand wires attracted only slightly less biofilm in vitro than multi-strand wires. Biofilms on stainless steel single-strand wires however, were much more susceptible to antimicrobials from toothpaste slurries and mouthrinses than on single-strand gold wires and biofilms on multi-strand wires. Also, in vivo significantly less biofilm was found on single-strand than on multi-strand wires. Microbial composition of biofilms was more dependent on the volunteer involved than on wire type.</p><p>Biofilms on single-strand stainless steel wires attract less biofilm in vitro and are more susceptible to antimicrobials than on multi-strand wires. Also in vivo, single-strand wires attract less biofilm than multi-strand ones.</p><p>Use of single-strand wires is preferred over multi-strand wires, not because they attract less biofilm, but because biofilms on single-strand wires are not protected against antimicrobials as in crevices and niches as on multi-strand wires.</p>
Protein Design: Toward Functional Metalloenzymes
The scope of this Review is to discuss the construction of metal sites in designed protein scaffolds. We categorize the effort of designing proteins into redesign, which is to rationally engineer desired functionality into an existing protein scaffold,(1-9) and de novo design, which is to build a peptidic or protein system that is not directly related to any sequence found in nature yet folds into a predicted structure and/or carries out desired reactions.(10-12) We will analyze and interpret the significance of designed protein systems from a coordination chemistry and biochemistry perspective, with an emphasis on those containing constructed metal sites as mimics for metalloenzymes