    Multicenter study of device-associated infection rates in hospitals of Mongolia: Findings of the International Nosocomial Infection Control Consortium (INICC)

    Get PDF
    Methods: A device-associated health care-associated infection prospective surveillance study in 3 adult intensive care units (ICUs) from 3 hospitals using the U.S. Centers for Disease Control and Prevention (CDC) and National Healthcare Safety Network (NHSN) definitions and INICC methods. Results: We documented 467 ICU patients for 2,133 bed days. The central line-associated bloodstream infection (CLABSI) rate was 19.7 per 1,000 central line days, the ventilator-associated pneumonia (VAP) rate was 43.7 per 1,000 mechanical ventilator days, and the catheter-associated urinary tract infection (CAUTI) rate was 15.7 per 1,000 urinary catheter days; all of the rates are higher than the INICC rates (CLABSI: 4.9; VAP: 16.5; and CAUTI: 5.3) and CDC-NHSN rates (CLABSI: 0.8; VAP: 1.1; and CAUTI: 1.3). Device use ratios were also higher than the CDC-NHSN and INICC ratios, except for the mechanical ventilator device use ratio, which was lower than the INICC ratio. Resistance of Staphylococcus aureus to oxacillin was 100%. Extra length of stay was 15.1 days for patients with CLABSI, 7.8 days for patients with VAP, and 8.2 days for patients with CAUTI. Extra crude mortality in the ICUs was 18.6% for CLABSI, 17.1% for VAP, and 5.1% for CAUTI. Conclusion: Device-associated health care-associated infection rates and most device use ratios in our Mongolian hospitals' ICUs are higher than the CDC-NSHN and INICC rates

    Chemical analysis of extracting transition metal oxides from polymetallic ore by sulphate process

    No full text
    In this research work we attempt to improve the purity of polymetallic ores in Mongolia whilst developing practical applications of its refinement processes and this paper presents the results of chemical research of extracting transition metal titanium oxides, ferrous oxide and rare earth oxides from polymetallic ore. Thereby, chemical and mineral analysis of polymetallic ore is carried out basis of responses to the support process at various degrees of water whereas transition metal sulphates solubility differ. As a result of sulphate and resulphurization process we have extracted anatase with 62.5 percent titanium dioxide and brookite mineral with 89.6 percent of titanium dioxide as well as mineral with 83.8 percent of ferrous oxide hematite and rare earth oxides with 57.6 percent of cerium oxide. These oxides are identified under various conditions in the thermal processing. The morphology structure and chemical content compound of the mineral has been verified as a result of the XRF, XRD, SEM-EDX analysis

    Chemical analysis of extracting transition metal oxides from polymetallic ore by sulphate process

    No full text
    In this research work we attempt to improve the purity of polymetallic ores in Mongolia whilst developing practical applications of its refinement processes and this paper presents the results of chemical research of extracting transition metal titanium oxides, ferrous oxide and rare earth oxides from polymetallic ore. Thereby, chemical and mineral analysis of polymetallic ore is carried out basis of responses to the support process at various degrees of water whereas transition metal sulphates solubility differ. As a result of sulphate and resulphurization process we have extracted anatase with 62.5 percent titanium dioxide and brookite mineral with 89.6 percent of titanium dioxide as well as mineral with 83.8 percent of ferrous oxide hematite and rare earth oxides with 57.6 percent of cerium oxide. These oxides are identified under various conditions in the thermal processing. The morphology structure and chemical content compound of the mineral has been verified as a result of the XRF, XRD, SEM-EDX analysis

    Multicenter study of device-associated infection rates in hospitals of Mongolia: Findings of the International Nosocomial Infection Control Consortium (INICC)

    No full text
    Background To report the results of the International Nosocomial Infection Control Consortium (INICC) multicenter study conducted in Mongolia from September 2013-March 2015. Methods A device-associated health care-associated infection prospective surveillance study in 3 adult intensive care units (ICUs) from 3 hospitals using the U.S. Centers for Disease Control and Prevention (CDC) and National Healthcare Safety Network (NHSN) definitions and INICC methods. Results We documented 467 ICU patients for 2,133 bed days. The central line-associated bloodstream infection (CLABSI) rate was 19.7 per 1,000 central line days, the ventilator-associated pneumonia (VAP) rate was 43.7 per 1,000 mechanical ventilator days, and the catheter-associated urinary tract infection (CAUTI) rate was 15.7 per 1,000 urinary catheter days; all of the rates are higher than the INICC rates (CLABSI: 4.9; VAP: 16.5; and CAUTI: 5.3) and CDC-NHSN rates (CLABSI: 0.8; VAP: 1.1; and CAUTI: 1.3). Device use ratios were also higher than the CDC-NHSN and INICC ratios, except for the mechanical ventilator device use ratio, which was lower than the INICC ratio. Resistance of Staphylococcus aureus to oxacillin was 100%. Extra length of stay was 15.1 days for patients with CLABSI, 7.8 days for patients with VAP, and 8.2 days for patients with CAUTI. Extra crude mortality in the ICUs was 18.6% for CLABSI, 17.1% for VAP, and 5.1% for CAUTI. Conclusion Device-associated health care-associated infection rates and most device use ratios in our Mongolian hospitals' ICUs are higher than the CDC-NSHN and INICC rates.Fil: Ider, Bat-Erdene. Intermed Hospital; MongoliaFil: Baatar, Otgon. State Central First Hospital; MongoliaFil: Rosenthal, Victor Daniel. International Nosocomial Infection Control Consortium; ArgentinaFil: Khuderchuluun, Chuluunchimeg. State Central First Hospital; MongoliaFil: Baasanjav, Battsetseg. State Central First Hospital; MongoliaFil: Donkhim, Chuluunbaatar. State Central First Hospital; MongoliaFil: Batsuur, Byambadorj. State Central First Hospital; MongoliaFil: Jambiimolom, Munhzul. Second State Central Hospital; MongoliaFil: Purevdorj, Suvd-Erdene. Second State Central Hospital; MongoliaFil: Tsogtbaatar, Uyanga. Second State Central Hospital; MongoliaFil: Sodnomdarjaa, Baigalmaa. Second State Central Hospital; MongoliaFil: Gendaram, Bayasgalan. Second State Central Hospital; MongoliaFil: Mendsaikhan, Naranpurev. Intermed Hospital; MongoliaFil: Begzjav, Tsolmon. Intermed Hospital; MongoliaFil: Narankhuu, Batsaikhan. Intermed Hospital; MongoliaFil: Ariungerel, Bat-Erdene. Intermed Hospital; MongoliaFil: Tumendemberel, Bolormaa. Intermed Hospital; MongoliaFil: Orellano, Pablo Wenceslao. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Tecnológica Nacional; Argentina. International Nosocomial Infection Control Consortium; Argentin

    International Nosocomial Infection Control Consortium report, data summary of 50 countries for 2010-2015: Device-associated module

    No full text
    •We report INICC device-associated module data of 50 countries from 2010-2015.•We collected prospective data from 861,284 patients in 703 ICUs for 3,506,562 days.•DA-HAI rates and bacterial resistance were higher in the INICC ICUs than in CDC-NHSN's.•Device utilization ratio in the INICC ICUs was similar to CDC-NHSN's. Background: We report the results of International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2010-December 2015 in 703 intensive care units (ICUs) in Latin America, Europe, Eastern Mediterranean, Southeast Asia, and Western Pacific. Methods: During the 6-year study period, using Centers for Disease Control and Prevention National Healthcare Safety Network (CDC-NHSN) definitions for device-associated health care-associated infection (DA-HAI), we collected prospective data from 861,284 patients hospitalized in INICC hospital ICUs for an aggregate of 3,506,562 days. Results: Although device use in INICC ICUs was similar to that reported from CDC-NHSN ICUs, DA-HAI rates were higher in the INICC ICUs: in the INICC medical-surgical ICUs, the pooled rate of central line-associated bloodstream infection, 4.1 per 1,000 central line-days, was nearly 5-fold higher than the 0.8 per 1,000 central line-days reported from comparable US ICUs, the overall rate of ventilator-associated pneumonia was also higher, 13.1 versus 0.9 per 1,000 ventilator-days, as was the rate of catheter-associated urinary tract infection, 5.07 versus 1.7 per 1,000 catheter-days. From blood cultures samples, frequencies of resistance of Pseudomonas isolates to amikacin (29.87% vs 10%) and to imipenem (44.3% vs 26.1%), and of Klebsiella pneumoniae isolates to ceftazidime (73.2% vs 28.8%) and to imipenem (43.27% vs 12.8%) were also higher in the INICC ICUs compared with CDC-NHSN ICUs. Conclusions: Although DA-HAIs in INICC ICU patients continue to be higher than the rates reported in CDC-NSHN ICUs representing the developed world, we have observed a significant trend toward the reduction of DA-HAI rates in INICC ICUs as shown in each international report. It is INICC's main goal to continue facilitating education, training, and basic and cost-effective tools and resources, such as standardized forms and an online platform, to tackle this problem effectively and systematically

    International Nosocomial Infection Control Consortiu (INICC) report, data summary of 43 countries for 2007-2012. Device-associated module

    No full text
    We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2007-December 2012 in 503 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study using the Centers for Disease Control and Prevention's (CDC) U.S. National Healthcare Safety Network (NHSN) definitions for device-associated health care–associated infection (DA-HAI), we collected prospective data from 605,310 patients hospitalized in the INICC's ICUs for an aggregate of 3,338,396 days. Although device utilization in the INICC's ICUs was similar to that reported from ICUs in the U.S. in the CDC's NHSN, rates of device-associated nosocomial infection were higher in the ICUs of the INICC hospitals: the pooled rate of central line–associated bloodstream infection in the INICC's ICUs, 4.9 per 1,000 central line days, is nearly 5-fold higher than the 0.9 per 1,000 central line days reported from comparable U.S. ICUs. The overall rate of ventilator-associated pneumonia was also higher (16.8 vs 1.1 per 1,000 ventilator days) as was the rate of catheter-associated urinary tract infection (5.5 vs 1.3 per 1,000 catheter days). Frequencies of resistance of Pseudomonas isolates to amikacin (42.8% vs 10%) and imipenem (42.4% vs 26.1%) and Klebsiella pneumoniae isolates to ceftazidime (71.2% vs 28.8%) and imipenem (19.6% vs 12.8%) were also higher in the INICC's ICUs compared with the ICUs of the CDC's NHSN