170 research outputs found

    A Novel UV Photon Detector with Resistive Electrodes

    Full text link
    In this study we present first results from a new detector of UV photons: a thick gaseous electron multiplier (GEM) with resistive electrodes, combined with CsI or CsTe/CsI photocathodes. The hole type structure considerably suppresses the photon and ion feedback, whereas the resistive electrodes protect the detector and the readout electronics from damage by any eventual discharges. This device reaches higher gains than a previously developed photosensitive RPC and could be used not only for the imaging of UV sources, flames or Cherenkov light, for example, but also for the detection of X-rays and charged particles.Comment: Presented at the International Workshop on Resistive Plate Chambers, Korea, October 200

    New hat feed for reflector antennas realised without dielectrics for reducing manufacturing cost and improving reflection coefficient

    Get PDF
    This study presents a new hat feed that is made entirely of metal without using dielectric material. Compared to previous hat feeds where a piece of dielectric is used to support the hat on the waveguide, the new feed has lower manufacturing cost and higher reliability. In addition, the new hat feed has low radiation along the feeding waveguide, which makes the vertex plate unnecessary. Therefore the bandwidth over which the reflection coefficient magnitude is below -15 dB has increased. The feed has been optimised using a genetic algorithm. A prototype has been manufactured, and measured results are presented to verify the numerical simulations

    Self-Heating Effects in a BiCMOS on SOI Technology for RFIC Applications

    Full text link

    Study of capillary-based gaseous detectors

    Full text link
    We have studied gain vs. voltage characteristics and position resolutions of multistep capillary plates (two or three capillary plates operating in a cascade), as well as capillary plates operating in a mode when the main amplification occurs between plates or between the capillary plate and the readout plate (parallel plate amplification mode). Results of these studies demonstrated that in the parallel-plate amplification mode one can reach both high gains (>100000) and good position resolutions (~100 micro meter) even with a single step arrangement. It offers a compact amplification structure, which can be used in many applications. For example, in preliminary tests we succeeded to combine it with a photocathode and use it as a position sensitive gaseous photomultiplier. CsI coated capillary plates could also be used as a high position resolution and high rate X-ray converter.Comment: Presented at the NSS IEEE 2003 conference in Portland, submitted to TN

    A High Position Resolution X-ray Detector: an Edge on Illuminated Capillary Plate Combined with a Gas Amplification Structure

    Full text link
    We have developed and successfully tested a prototype of a new type of high position resolution hybrid X-ray detector. It contains a thin wall lead glass capillary plate converter of X-rays combined with a microgap parallel-plate avalanche chamber filled with gas at 1 atm. The operation of these converters was studied in a wide range of X-ray energies (from 6 to 60 keV) at incident angles varying from 0-90 degree. The detection efficiency, depending on the geometry, photon energy, incident angle and the mode of operation, was between 5-30 percent in a single step mode and up to 50 percent in a multi-layered combination. Depending on the capillary geometry, the position resolution achieved was between 0.050-0.250 mm in digital form and was practically independent of the photon energy or gas mixture. The usual lead glass capillary plates operated without noticeable charging up effects at counting rates of 50 Hz/mm2, and hydrogen treated capillaries up to 10E5 Hz/mm2. The developed detector may open new possibilities for medical imaging, for example in mammography, portal imaging, radiography (including security devices), crystallography and many other applications.Comment: Presented at the IEEE Nuclear Science Symposium, Roma, Octber 200

    The Development and Study of High-Position Resolution (50 micron) RPCs for Imaging X-rays and UV photons

    Full text link
    Nowadays, commonly used Resistive Plate Chambers (RPCs) have counting rate capabilities of ~10E4Hz/cm2 and position resolutions of ~1cm. We have developed small prototypes of RPCs (5x5 and 10x10cm2) having rate capabilities of up to 10E7Hz/cm2 and position resolutions of 50 micron("on line" without application of any treatment method like "center of gravity"). The breakthrough in achieving extraordinary rate and position resolutions was only possible after solving several serious problems: RPC cleaning and assembling technology, aging, spurious pulses and afterpulses, discharges in the amplification gap and along the spacers. High-rate, high-position resolution RPCs can find a wide range of applications in many different fields, for example in medical imaging. RPCs with the cathodes coated by CsI photosensitive layer can detect ultraviolet photons with a position resolution that is better than ~30 micron. Such detectors can also be used in many applications, for example in the focal plane of high resolution vacuum spectrographs or as image scanners.Comment: 6 pages, 5 figures, other comment

    Cognitive neuroscience of delusions in aging

    Get PDF
    Assessments and clinical understanding of late-onset delusions in the elderly are inconsistent and often incomplete. In this review, we consider the prevalence, neurobehavioral features, and neuroanatomic correlations of delusions in elderly persons – those with documented cognitive decline and those with no evidence of cognitive decline. Both groups exhibit a common phenotype: delusions are either of persecution or of misidentification. Late-onset delusions show a nearly complete absence of the grandiose, mystical, or erotomanic content typical of early onset psychoses. Absent also from both elderly populations are formal thought disorders, thought insertions, and delusions of external control. Neuroimaging and behavioral studies suggest a frontotemporal localization of delusions in the elderly, with right hemispheric lateralization in delusional misidentification and left lateralization in delusions of persecution. We propose that delusions in the elderly reflect a common neuroanatomic and functional phenotype, and we discuss applications of our proposal to diagnosis and treatment

    Jimmy Swaggart's Secular Confession

    Get PDF
    This is the author's accepted manuscript. The published version is available from http://dx.doi.org/10.1080/02773940902766748 .Following the exposure of televangelist Jimmy Swaggart’s illicit rendezvous with a New Orleans prostitute, the Assemblies of God simultaneously orchestrated a massive attempt to silence those who would discuss the tryst and arranged the most widely publicized confession in American history theretofore. The coincidence of a “silence campaign” with the vast distribution of a public confession invites us to reconsider the nature of the public confession. For what place has a public confession, the discourse of disclosure par excellence, in a silence campaign? This question is best answered, I argue, if we understand public confession not as a stable a-historical form, but as a practice that is informed by multiple, competing traditions. I argue that by situating Swaggart’s performance in a philosophically modern and secular tradition of public confession we can understand both its complicity in a silence campaign and, more generally, the political logic of the modern public confession
    • …
    corecore