116 research outputs found

    CCD BVRI and 2MASS Photometry of the Poorly Studied Open Cluster NGC 6631

    Get PDF
    Here we have obtained the {\it BVRI CCD} photometry down to a limiting magnitude of V∼V \sim 20 for the southern poorly studied open cluster NGC 6631. It is observed from the {\it 1.88 m} Telescope of Kottamia Observatory in Egypt. About 3300 stars have been observed in an area of ∼10′×10′\sim 10^{\prime} \times 10^{\prime} around the cluster center. The main photometric parameters have been estimated and compared with the results that determined for the cluster using {\it JHKs 2MASS} photometric database. The cluster's diameter is estimated to be 10 arcmin; the reddening E(B-V)= 0.68 ±\pm 0.10 mag, E(J-H)= 0.21 ±\pm 0.10 mag, the true modulus (m-M)o_{o}= 12.16 ±\pm 0.10 mag, which corresponds to a distance of 2700 ±\pm125 pc and age of 500 ±\pm 50 Myr.Comment: 13 pages, 6 figure

    Bilateral acute angle closure glaucoma after hyperopic LASIK correction

    Get PDF
    AbstractAcute angle closure glaucoma is unexpected complication following laser in situ keratomileusis (LASIK). We are reporting a 49-years-old lady that was presented to the emergency department with acute glaucoma in both eyes soon after LASIK correction. Diagnosis was made on detailed clinical history and examination, slit lamp examination, intraocular pressure measurement and gonioscopy. Laser iridotomy in both eyes succeeded in controlling the attack and normalizing the intraocular pressure (IOP) more than 6months of follow-up. Prophylactic laser iridotomy is essential for narrow angle patients before LASIK surgery if refractive laser surgery is indicated

    A COMPARISON BETWEEN THE EFFECT OF DIFFERENT PRESSURES OF AIR PARTICLE ABRASION BEFORE AND AFTER SINTERING WITH AND WITHOUT ZIRCONIA LINER ON BOND STRENGTH OF RESIN TO ZIRCONIA SURFACE

    Get PDF
    This study aimed to compare the effect of different pressures of air particle abrasion 2 and 4 bars before and after sintering with and without zirconia liner on SBS of resin to zirconia Surface. Materials and Methods: 54 zirconia cuboids 8×8×3 mm were milled and divided into 6 equal groups (N=9) according to surface treatment; sintered with ceramic liner application and 2 bars pressure (SL2) and with 4 bars pressure (SL4), sintered with no ceramic liner and 2 bars pressure (SN2) and 4 bars pressure (SN4), unsintered with no ceramic liner and 2 bars pressure (UN2) and 4 bars pressure (UN4). Specimens underwent thermocycling (1000 cycles) between 5 ̊ and 55 ̊ Celsius with dwell time of 10 seconds, and submitted to SBS test. Data was statistically analysed. Results: All 4 bars APA groups showed higher SBS than 2 bars groups with significant difference between SL4 group (4.7±2.07) and SL2 group (2.58±1.94). Groups with APA before sintering (12.42±2.56) showed significantly higher SBS than APA after sintering (6.35±3.7). SL2 group showed least SBS with significant difference (2.58±1.94) compared to UN2 (11.83±3.35) and SN2 (7.87±2.12). SL4 group (4.7±2.07) showed the least SBS compared to the UN4 (13±1.38), and SN4 (10.24±2.94) groups. Conclusion: It was found that APA of zirconia surface before sintering yielded superior performance than APA after sintering, also 4 bars APA pressure application showed higher SBS than 2 bars pressure, application and firing of ceramic liner onto zirconia surface didn’t enhance SBS

    STRESS ANALYSIS COMPARING EFFECT OF TWO DIFFERENT CAD-CAM IMPLANT SUPERSTRUCTURE MATERIALS (IN-VITRO STUDY)

    Get PDF
    Purpose: This study was conducted to evaluate the micro-strain around dental implant using two different CAD/CAM crown fabricated materials through strain gauge analysis. Materials and Methods: Five dental implants were fixed in a 5 previously drilled solid rigid polyurethane test blocks in the edentulous area with neighboring abutments mesial and distal printed out using special 3D Dental printer, Cyanoacrylate adhesive was then used to fix the printed-out part on to the polyurethane test blocks, creating the bounded saddle replicas. Ten CAD/CAM screw retained crowns were fabricated; five Enamic crowns from vita enamic blocks, and five zirconia crowns from presintered katana zirconium blocks. Each crown was cemented to abutment and screwed over the implant fixture. Two strain gauges were installed on their corresponding prepared sites to measure the micro-strains in the medium surrounding the implant. For each tested implant, loads were applied by a universal testing machine, micro-strains were recorded with the strain gauges and stress distribution around the implant was statistically evaluated. Results: Micro-strain recording revealed a statistically significant difference in mean micro-strain recording applied in central fossa between Zirconia and Enamic, for both the buccal and lingual measurements, Enamic was significantly lower than Zirconia. Conclusion: The modulus of elasticity of restorative materials has a meaningful effect on forces applied to dental implant and transmitted to the supporting bone
    • …
    corecore