172 research outputs found

    Spatially-Coupled MacKay-Neal Codes with No Bit Nodes of Degree Two Achieve the Capacity of BEC

    Full text link
    Obata et al. proved that spatially-coupled (SC) MacKay-Neal (MN) codes achieve the capacity of BEC. However, the SC-MN codes codes have many variable nodes of degree two and have higher error floors. In this paper, we prove that SC-MN codes with no variable nodes of degree two achieve the capacity of BEC

    Development of Flat Tube Heat Exchanger for Heat Pump Air Conditoner

    Get PDF
    We developed a new type of a heat pump outdoor unit using an aluminum flat tube heat exchanger in order to improve the energy saving capability of an air conditioner. There are several difficulties in keeping a desired drainage performance, frost formation performance, as well as even distribution of refrigerant, when applying the flat tube heat exchanger to heat pump outdoor units. In order to achieve the same drainage performance and the frost formation performance as those of conventional heat exchangers, we have adopted new plate fins with ellipse cutouts. Flat tubes were inserted in the ellipse cutouts, and the slit position on a plate fin was properly adjusted. In order to achieve the even distribution of refrigerant, an aluminum distributor and 3-way pipes were installed to the evaporator. In this report, first we describe features of the flat tube heat exchanger. Next, we present and explain experimental results of the air-side heat transfer coefficient and the air-side pressure drop on the condition of dry, wet, and frost state respectively. Moreover, we present experimental results of the total heat transfer performance, including the refrigerant performance, under the conditions of the condensation and the evaporation. Finally, we explain the heat transfer performance and the effect of the flat tube heat exchanger to a conventional one in the case that the developed heat exchanger was mounted in heat pump outdoor unit

    Medial meniscus posterior root tear causes swelling of the medial meniscus and expansion of the extruded meniscus: a comparative analysis between 2D and 3D MRI

    Get PDF
    Purpose This study aimed to clarify the advantages of three-dimensional (3D) magnetic resonance imaging (MRI) over two-dimensional (2D) MRI in measuring the size of the medial meniscus (MM) and to analyse the volumes of MM and the extruded meniscus in patients with MM posterior root tear (MMPRT), at 10° and 90° knee flexion. Methods This study included 17 patients with MMPRTs and 15 volunteers with uninjured knees. The MMs were manually segmented for 3D reconstruction; thereafter, the extruded part separated from the tibial edge was determined. The length, width, height, and extrusion of MM were measured by the 2D and 3D methods, and compared. The MM volume, extruded meniscus volume, and their ratio were also calculated using 3D analysis software in the two groups. Results The estimated length and posterior height of MM were larger with 3D MRI than with 2D MRI measurements. The MM volume was significantly greater in MMPRT knees than in normal knees, with increasing MM height. In MMPRT knees, the mean volume of the extruded meniscus and its ratio significantly increased by 304 mm3 (p = 0.02) and 9.1% (p  Conclusions This study demonstrated that 3D MRI could estimate the precise MM size and that MMPRT caused swelling of the meniscus due to the increased thickness in the posteromedial part. The clinical significance of this study lies in its 3D evaluation of MM volume, which should help the surgeon understand the biomechanical failure of MM function and improve MMPRT repair technique

    Spectropolarimetric Study on Circumstellar Structure of Microquasar LS I +61deg 303

    Get PDF
    We present optical linear spectropolarimetry of the microquasar LS I +61^{\circ} 303. The continuum emission is mildly polarized (up to 1.3 %) and shows almost no temporal change. We find a distinct change of polarization across the Hα\alpha emission line, indicating the existence of polarization component intrinsic to the microquasar. We estimate the interstellar polarization (ISP) component from polarization of the Hα\alpha line and derive the intrinsic polarization component. The wavelength dependence of the intrinsic component is well explained by Thomson scattering in equatorial disk of the Be-type mass donor. The position angle (PA) of the intrinsic polarization 25\sim 25^{\circ} represents the rotational axis of the Be disk. This PA is nearly perpendicular to the PA of the radio jet found during quiescent phases. Assuming an orthogonal disk-jet geometry around the compact star, the rotational axis of the accretion disk is almost perpendicular to that of the Be disk. Moreover, according to the orbital parameters of the microquasar, the compact star is likely to get across the Be disk around their periastron passage. We discuss the peculiar circumstellar structure of this microquasar inferred from our observation and possible connection with its high-energy activities.Comment: 17pages, 7figures; accepted for Publications of the Astronomical Society of Japa

    Evaluation of calibration factor of OSLD toward eye lens exposure dose measurement of medical staff during IVR

    Get PDF
    The eye lens is a sensitive organ of which an x‐ray exposure dose should be managed during interventional radiology (IVR). In the actual situations, the eye lens is exposed to scattered x‐rays; they have different from the standard x‐ray energies which are used for general dose calibration of the dosimeter. To perform precise dose measurement, the energy dependence of the dosimeter should be properly accounted for when calibrating the dosimeter. The vendor supplies a calibration factor using 80‐kV diagnostic x‐rays under a free‐air condition. However, whether it is possible to use this calibration factor to evaluate the air kerma during the evaluation of the eye lens dose is unclear. In this paper, we aim to precisely determine calibration factors, and also examine the possible application of using a vendor‐supplied calibration factor. First, the x‐ray spectrum at the eye lens position during fluoroscopy was measured with a CdTe x‐ray spectrometer. We mimicked transfemoral cardiac catheterization using a human‐type phantom. Second, we evaluated the doses and calibration factors at three dosimetric points: front and back of protective goggles, and the front of the head (eye lens position). We used the measured x‐ray spectrum to determine the incident photon distribution in the eye lens regions, and x‐ray spectra corresponding to the dosimetric points around the eye lens were estimated using Monte Carlo simulation. Although the calibration factors varied with dosimetric positions, we found that the factors obtained were similar to the vendor‐supplied calibration factor. Furthermore, based on the experiment, we propose a practical way to calibrate an OSL dosimeter in an actual clinical situation. A person evaluating doses can use a vendor‐supplied calibration factor without any corrections for energy dependences, only when they add a systematic uncertainty of 5%. This evidence will strongly support actual exposure dose measurement during a clinical study

    μ1B, a novel adaptor medium chain expressed in polarized epithelial cells11The nucleotide sequences reported in this paper have been submitted to GenBank with accession numbers AF020797 (human μ1B) and AF067146 (mouse μ1B).

    Get PDF
    AbstractThe apical and basolateral plasma membrane domains of polarized epithelial cells contain distinct sets of integral membrane proteins. Biosynthetic targeting of proteins to the basolateral plasma membrane is mediated by cytosolic tail determinants, many of which resemble signals involved in the rapid endocytosis or lysosomal targeting. Since these signals are recognized by adaptor proteins, we hypothesized that there could be epithelial-specific adaptors involved in polarized sorting. Here, we report the identification of a novel member of the adaptor medium chain family, named μ1B, which is closely related to the previously described μ1A (79% amino acid sequence identity). Northern blotting and in situ hybridization analyses reveal the specific expression of μ1B mRNA in a subset of polarized epithelial and exocrine cells. Yeast two-hybrid analyses show that μ1B is capable of interacting with generic tyrosine-based sorting signals. These observations suggest that μ1B may be involved in protein sorting events specific to polarized cells
    corecore