    Development of Bioactivity and Pull-out Torque Control Technology on Ti Implant Surface and its Application for Cold Thread Rolled Bone Screw

    Get PDF
    AbstractThe influence of cold thread rolling conditions and a production method of titania (TiO2) films on surface bioactivity and pull-out torque of a titanium bone screw was investigated. The bone screw with micro surface roughness distribution was formed by cold thread rolling with a pair of parallel dies. The die shape and surface roughness distribution were changed to the 3 grades. The TiO2 films were coated on the surface of the bone screw using anodizing in aqueous solutions (hydro-coating). We introduced the rolled bone screws into tibia of rats for two weeks and examined the effects of the combinations of the surface morphology and the TiO2 film on osteoconductivity in an in-vivo experiment. As the results, it is found that we could control the bioactivity and pull-out torque by controlling the surface roughness at the bottom of the screw root

    National trends in the outcomes of subarachnoid haemorrhage and the prognostic influence of stroke centre capability in Japan: retrospective cohort study

    No full text
    Objectives To examine the national, 6-year trends in in-hospital clinical outcomes of patients with subarachnoid haemorrhage (SAH) who underwent clipping or coiling and the prognostic influence of temporal trends in the Comprehensive Stroke Center (CSC) capabilities on patient outcomes in Japan.Design Retrospective study.Setting Six hundred and thirty-one primary care institutions in Japan.Participants Forty-five thousand and eleven patients with SAH who were urgently hospitalised, identified using the J-ASPECT Diagnosis Procedure Combination database.Primary and secondary outcome measures Annual number of patients with SAH who remained untreated, or who received clipping or coiling, in-hospital mortality and poor functional outcomes (modified Rankin Scale: 3–6) at discharge. Each CSC was assessed using a validated scoring system (CSC score: 1–25 points).Results In the overall cohort, in-hospital mortality decreased (year for trend, OR (95% CI): 0.97 (0.96 to 0.99)), while the proportion of poor functional outcomes remained unchanged (1.00 (0.98 to 1.02)). The proportion of patients who underwent clipping gradually decreased from 46.6% to 38.5%, while that of those who received coiling and those left untreated gradually increased from 16.9% to 22.6% and 35.4% to 38%, respectively. In-hospital mortality of coiled (0.94 (0.89 to 0.98)) and untreated (0.93 (0.90 to 0.96)) patients decreased, whereas that of clipped patients remained stable. CSC score improvement was associated with increased use of coiling (per 1-point increase, 1.14 (1.08 to 1.20)) but not with short-term patient outcomes regardless of treatment modality.Conclusions The 6-year trends indicated lower in-hospital mortality for patients with SAH (attributable to better outcomes), increased use of coiling and multidisciplinary care for untreated patients. Further increasing CSC capabilities may improve overall outcomes, mainly by increasing the use of coiling. Additional studies are necessary to determine the effect of confounders such as aneurysm complexity on outcomes of clipped patients in the modern endovascular era
    corecore