15 research outputs found

    A case report of an interrupted inferior vena cava and azygos continuation:Implications for preoperative screening in minimally invasive cardiac surgery

    Get PDF
    Background: Femoral cannulation is commonly used in minimally invasive cardiac surgery to establish extracorporeal circulation. We present a case with a finding that should be evaluated when screening candidates for minimally invasive cardiac surgery. Case summary: A 57-year-old male patient was scheduled for minimally invasive repair of the mitral and tricuspid valve and a MAZE procedure. During surgery there was difficulty advancing the venous cannula inserted in the right femoral vein. On transoesophageal echocardiography a guidewire advanced from the femoral vein was observed entering the right atrium from the superior vena cava. Despite inserting a second venous cannula in the jugular vein, venous drainage was insufficient for minimal invasive surgery. The approach was converted to a median sternotomy with bicaval cannulation. Re-examination of the preoperative computed tomography (CT) scan showed an interrupted inferior vena cava (IVC) with azygos continuation. Discussion: In patients with major venous malformations such as the interrupted IVC with azygos continuation a full sternotomy is the preferred approach. The venous system should be evaluated when screening candidates for minimally invasive mitral valve surgery with preoperative CT. Additional cues to suspect interruption of the IVC are polysplenia and a broad superior mediastinal projection on the chest radiograph, mimicking a right paratracheal mass.</p

    The role of experience in echocardiographic identification of location and extent of mitral valve prolapse with 2D and 3D echocardiography

    Get PDF
    Contradiction exists on the incremental value of two-dimensional (2D) and 3D transoesophageal echocardiography (TOE) over 2D transthoracic echocardiography (TTE) for the detection of mitral valve (MV) prolapse in readers with different echocardiographic experience. Twenty patients and five healthy persons were retrospectively identified who had undergone 2D-TTE, 2D-TOE and 3D-TOE. Fifteen (75 %) patients had surgical evidence of prolapse of the posterior MV leaflet and five patients (25 %) had a dilated MV annulus without prolapse. Three reader groups with different echocardiographic expertise (novice, trainees, cardiologists) scored thus in total 675 posterior scallops. Overall there was an improvement in agreement and Kappa values from novice to trainees to cardiologists. Diagnostic accuracies of 2D-TOE were higher than those of 2D-TTE mainly in novice readers. The incremental value of 3D-TOE over 2D-TOE was mainly seen in specificities. Time to diagnosis was dramatically reduced from 2D to 3D-TEE in all reader groups (all P < 0.001). 3D-TOE also improved the agreement (+12 to +16 %) and Kappa values (+0.14 to +0.21) in all reader groups for the exact description of P2 prolapse. Differences between readers with variable experience in determining the precise localization and extent of the prolapsing posterior MV scallops exist in particular in 2D-TTE analysis. 3D-TOE analysis was extremely fast compared to the 2D analysis methods and showed the best diagnostic accuracy (mainly driven by specificity) with identification of P1 and P3 prolapse still improving from novice to trainees to cardiologists and provided optimal description of P2 prolapse extent

    A modified echocardiographic classification of mitral valve regurgitation mechanism: The role of three-dimensional echocardiography

    Get PDF
    In this report, we provide an overview of a new, updated echocardiographic classification of mitral regurgitation mechanisms to provide a more comprehensive and detailed assessment of mitral valve disorders. This is relevant to modern mitral valve repair techniques, with special attention to the added value of 3D-echocardiography

    Interprofessional Consensus Regarding Design Requirements for Liquid-Based Perinatal Life Support (PLS) Technology

    Get PDF
    Liquid-based perinatal life support (PLS) technology will probably be applied in a first-in-human study within the next decade. Research and development of PLS technology should not only address technical issues, but also consider socio-ethical and legal aspects, its application area, and the corresponding design implications. This paper represents the consensus opinion of a group of healthcare professionals, designers, ethicists, researchers and patient representatives, who have expertise in tertiary obstetric and neonatal care, bio-ethics, experimental perinatal animal models for physiologic research, biomedical modeling, monitoring, and design. The aim of this paper is to provide a framework for research and development of PLS technology. These requirements are considering the possible respective user perspectives, with the aim to co-create a PLS system that facilitates physiological growth and development for extremely preterm born infants

    Diffusion-Weighted MRI for Selection of Complete Responders After Chemoradiation for Locally Advanced Rectal Cancer: A Multicenter Study

    Get PDF
    PURPOSE: In 10-24% of patients with rectal cancer who are treated with neoadjuvant chemoradiation, no residual tumor is found after surgery (ypT0). When accurately selected, these complete responders might be considered for less invasive treatments instead of standard surgery. So far, no imaging method has proven reliable. This study was designed to assess the accuracy of diffusion-weighted MRI (DWI) in addition to standard rectal MRI for selection of complete responders after chemoradiation. METHODS: A total of 120 patients with locally advanced rectal cancer from three university hospitals underwent chemoradiation followed by a restaging MRI (1.5T), consisting of standard T2W-MRI and DWI (b0-1000). Three independent readers first scored the standard MRI only for the likelihood of a complete response using a 5-point confidence score, after which the DWI images were added and the scoring was repeated. Histology (ypT0 vs. ypT1-4) was the standard reference. Diagnostic performance for selection of complete responders and interobserver agreement were compared for the two readings. RESULTS: Twenty-five of 120 patients had a complete response (ypT0). Areas under the ROC-curve for the three readers improved from 0.76, 0.68, and 0.58, using only standard MRI, to 0.8, 0.8, and 0.78 after addition of DWI (P = 0.39, 0.02, and 0.002). Sensitivity for selection of complete responders ranged from 0-40% on standard MRI versus 52-64% after addition of DWI. Specificity was equally high (89-98%) for both reading sessions. Interobserver agreement improved from kappa 0.2-0.32 on standard MRI to 0.51-0.55 after addition of DWI. CONCLUSIONS: Addition of DWI to standard rectal MRI improves the selection of complete responders after chemoradiation

    initial clinical experience with minimally invasive surgical aortic valve replacement

    No full text
    BaCKground: The ministernotomy approach is increasingly used in aortic valve surgery. however, the advantages are still a matter of discussion. The aim of this study was to compare the postoperative outcome in patients undergoing elective aortic valve operation, either through mini-sternotomy or conventional sternotomy. MeThods: We included 317 patients who were treated for their aortic valve, 63 patients underwent a minimally invasive aortic valve replacement (mini-avr) and 254 patients underwent a full-sternotomy avr. Patients with endocarditis, those who underwent previous cardiac surgery and those who required a concomitant procedure were excluded from the analysis. The method of matching weights according to propensity score was used to adjust for differences between the two treatment groups, and outcomes were compared. RESULTS: The mediastinal drainage was significantly lower at 6, 24 hours and total after mini-AVR procedure than after full-sternotomy AVR (median: 373 vs. 499 ml, P&lt;0.001). however, the number of patients receiving packed red blood cells transfusion was similar. overall, the hospital mortality was lower in the full-sternotomy group, 0% vs. 3.2%, P=0.039. no difference was found in the median hospital length of stay, perioperative myocardial infarction, postoperative incidence of new pacemaker implantation, stroke, prolonged mechanical ventilation and mediastinitis. no patients in the mini-avr group experienced paravalvular leakage. Midterm survival resulted in no difference between the treatment groups at 4-year (90.5% vs. 95.2%), P=0.75. ConClusions: although the minimally invasive surgery for avr may increasingly be applied, our initial experience calls for a careful approach of adapting this procedure.</p

    Asymptomatic Patients with Severe Aortic Stenosis and the Impact of Intervention

    No full text
    Objectives the exact timing of aortic valve replacement (AVR) in asymptomatic patients with severe aortic stenosis (AS) remains a matter of debate. Therefore, we described the natural history of asymptomatic patients with severe AS, and the effect of AVR on long-term survival. Methods: Asymptomatic patients who were found to have severe AS between June 2006 and May 2009 were included. Severe aortic stenosis was defined as peak aortic jet velocity Vmax ≥ 4.0 m/s or aortic valve area (AVA) ≤ 1 cm2. Development of symptoms, the incidence of AVR, and all-cause mortality were assessed. Results: A total of 59 asymptomatic patients with severe AS were followed, with a mean follow-up of 8.9 ± 0.4 years. A total of 51 (86.4%) patients developed AS related symptoms, and subsequently 46 patients underwent AVR. The mean 1-year, 2-year, 5-year, and 10-year overall survival rates were higher in patients receiving AVR compared to those who did not undergo AVR during follow-up (100%, 93.5%, 89.1%, and 69.4%, versus 92.3%, 84.6%, 65.8%, and 28.2%, respectively; p &lt; 0.001). Asymptomatic patients with severe AS receiving AVR during follow-up showed an incremental benefit in survival of up to 31.9 months compared to conservatively managed patients (p = 0.002). Conclusions: The majority of asymptomatic patients turn symptomatic during follow-up. AVR during follow-up is associated with better survival in asymptomatic severe AS patients

    Transthoracic two-dimensional xPlane and three-dimensional echocardiographic analysis of the site of mitral valve prolapse

    Get PDF
    This study sought to assess the value of two-dimensional (2D) transthoracic echocardiography (TTE), 2D xPlane imaging and three-dimensional (3D) TTE for the definition of the site and the extent of mitral valve (MV) prolapse. Fifty patients underwent transthoracic 2D, 2D xPlane and 3D echocardiography. With 2D xPlane a segmental analysis of the MV was performed, by making a lateral sweep across the MV coaptation line as seen in the parasternal short-axis view. Inter-observer agreement for specific scallop prolapse was for 2D xPlane excellent (97 %, kappa = 0.94) and for 3D TTE moderate (85 %, kappa = 0.67). The respective sensitivities of standard 2D TTE, 2D xPlane, and 3D TTE for the identification of the precise posterior scallop prolapse were for P1 92, 85, and 92 %, for P2 96, 96, and 82 %, and for P3 86, 81, and 71 %. In total, 5 (8 %) prolapsing MV scallops were missed by 2D TTE, 7 (12 %) by 2D xPlane, and 12 (20 %) by 3D TTE. The sensitivity of 3D TTE was significantly lower than standard 2D imaging (80 % versus 93 %, P < 0.05). The extent of P2 prolapse was under or overestim
    corecore