2 research outputs found

    Myocardial Dysfunction: A Primary Cause of Death Due To Severe Malaria in A Plasmodium falciparum-Infected Humanized Mouse Model

    No full text
    Background: Our study aimed at substantiating the recent claim of myo-cardial complications in severe malaria by experimentally inducing severe Plasmodium falciparum infection in a humanized mouse model employed as human surrogate. Methods: Twenty five humanized mice were inoculated with standard in vitro cultured P. falciparum and blood extracts collected from the inner cardiac muscles of infected mice that died were examined for the presence of the infectious cause of death. The therapeutic effect of quinine on 7 mice se-verely infected with P. falciparum was also evaluated. Results: All the 25 humanized mice inoculated with the in vitro cultured P. falciparum revealed peripheral parasitemia with a total of 10 deaths recorded. Postmortem examination of the inner cardiac muscles of the dead mice also revealed massive sequestration of mature P. falciparum as well as significant infiltration of inflammatory cells such as lymphocytes and monocytes. Post-mortem evaluation of the inner cardiac muscles of the P. falciparum-infected mice after quinine therapy showed significant decline in parasite density with no death of mice recorded. Conclusions: Data obtained from our study significantly corroborated the findings of myocardial dysfunction as the primary cause of death in recent case reports of humans infected with P. falciparum

    Biorisk Assessment of Medical Diagnostic Laboratories in Nigeria

    Get PDF
    Background: The aim of this study was to assess public and private medical diagnostic laboratories in Nigeria for the presence of biosafety equipment, devices, and measures. Methods: A total of 80 diagnostic laboratories in biosafety level 3 were assessed for the presence of biosafety equipment, devices, and compliance rate with biosafety practices. A detailed questionnaire and checklist was used to obtain the relevant information from enlisted laboratories. Results: The results showed the presence of an isolated unit for microbiological work, leak-proof working benches, self-closing doors, emergency exits, fire extinguisher(s), autoclaves, and hand washing sinks in 21.3%, 71.3%, 15.0%, 1.3%, 11.3%, 82.5%, and 67.5%, respectively, of all laboratories surveyed. It was observed that public diagnostic laboratories were significantly more likely to have an isolated unit for microbiological work (p = 0.001), hand washing sink (p = 0.003), and an autoclave (p ≤ 0.001) than private ones. Routine use of hand gloves, biosafety cabinet, and a first aid box was observed in 35.0%, 20.0%, and 2.5%, respectively, of all laboratories examined. Written standard operating procedures, biosafety manuals, and biohazard signs on door entrances were observed in 6.3%, 1.3%, and 3.8%, respectively, of all audited laboratories. No biosafety officer(s) or records of previous spills, or injuries and accidents, were observed in all diagnostic laboratories studied. Conclusion: In all laboratories (public and private) surveyed, marked deficiencies were observed in the area of administrative control responsible for implementing biosafety. Increased emphasis on provision of biosafety devices and compliance with standard codes of practices issued by relevant authorities is strongly advocated
    corecore