25 research outputs found

    Observation of a J^PC = 1-+ exotic resonance in diffractive dissociation of 190 GeV/c pi- into pi- pi- pi+

    Get PDF
    The COMPASS experiment at the CERN SPS has studied the diffractive dissociation of negative pions into the pi- pi- pi+ final state using a 190 GeV/c pion beam hitting a lead target. A partial wave analysis has been performed on a sample of 420000 events taken at values of the squared 4-momentum transfer t' between 0.1 and 1 GeV^2/c^2. The well-known resonances a1(1260), a2(1320), and pi2(1670) are clearly observed. In addition, the data show a significant natural parity exchange production of a resonance with spin-exotic quantum numbers J^PC = 1-+ at 1.66 GeV/c^2 decaying to rho pi. The resonant nature of this wave is evident from the mass-dependent phase differences to the J^PC = 2-+ and 1++ waves. From a mass-dependent fit a resonance mass of 1660 +- 10+0-64 MeV/c^2 and a width of 269+-21+42-64 MeV/c^2 is deduced.Comment: 7 page, 3 figures; version 2 gives some more details, data unchanged; version 3 updated authors, text shortened, data unchange

    Modeling elastic wave propagation in kidney stones with application to shock wave lithotripsy.

    No full text
    A time-domain finite-difference solution to the equations of linear elasticity was used to model the propagation of lithotripsy waves in kidney stones. The model was used to determine the loading on the stone (principal stresses and strains and maximum shear stresses and strains) due to the impact of lithotripsy shock waves. The simulations show that the peak loading induced in kidney stones is generated by constructive interference from shear waves launched from the outer edge of the stone with other waves in the stone. Notably the shear wave induced loads were significantly larger than the loads generated by the classic Hopkinson or spall effect. For simulations where the diameter of the focal spot of the lithotripter was smaller than that of the stone the loading decreased by more than 50%. The constructive interference was also sensitive to shock rise time and it was found that the peak tensile stress reduced by 30% as rise time increased from 25 to 150 ns. These results demonstrate that shear waves likely play a critical role in stone comminution and that lithotripters with large focal widths and short rise times should be effective at generating high stresses inside kidney stones

    A dual passive cavitation detector for localized detection of lithotripsy-induced cavitation in vitro.

    No full text
    A passive cavitation detector (PCD) identifies cavitation events by sensing acoustic emissions generated by the collapse of bubbles. In this work, a dual passive cavitation detector (dual PCD), consisting of a pair of orthogonal confocal receivers, is described for use in shock wave lithotripsy. Cavitation events are detected by both receivers and can be localized to within 5 mm by the nature of the small intersecting volume of the focal areas of the two receivers in association with a coincidence detection algorithm. A calibration technique, based on the impulse response of the transducer, was employed to estimate radiated pressures at collapse near the bubble. Results are presented for the in vitro cavitation fields of both a clinical and a research electrohydraulic lithotripter. The measured lifetime of the primary growth-and-collapse of the cavitation bubbles increased from 180 to 420 microseconds as the power setting was increased from 12 to 24 kV. The measured lifetime compared well with calculations based on the Gilmore-Akulichev formulation for bubble dynamics. The radiated acoustic pressure 10 mm from the collapsing cavitation bubble was measured to vary from 4 to 16 MPa with increasing power setting; although the trends agreed with calculations, the predicted values were four times larger than measured values. The axial length of the cavitation field correlated well with the 6-dB region of the acoustic field. However, the width of the cavitation field (10 mm) was significantly narrower than the acoustic field (25 mm) as bubbles appeared to be drawn to the acoustic axis during the collapse. The dual PCD also detected signals from "rebounds," secondary and tertiary growth-and-collapse cycles. The measured rebound time did not agree with calculations from the single-bubble model. The rebounds could be fitted to a Rayleigh collapse model by considering the entire bubble cloud as an effective single bubble. The results from the dual PCD agreed well with images from high-speed photography. The results indicate that single-bubble theory is sufficient to model lithotripsy cavitation dynamics up to time of the main collapse, but that upon collapse bubble cloud dynamics becomes important

    Detecting fragmentation of kidney stones in lithotripsy by means of shock wave scattering

    No full text
    Although extracorporeal shock wave lithotripsy (a procedure of kidney stone comminution using focused shock waves) has been used clinically for many years, a proper monitoring of the stone fragmentation is still undeveloped. A method considered here is based on recording shock wave scattering signals with a focused receiver placed far from the stone, outside the patient body. When a fracture occurs in the stone or the stone becomes smaller, the elastic waves in the stone will propagate differently (e.g. shear waves will not cross a fracture) which, in turn, will change the scattered acoustic wave in the surrounding medium. Theoretical studies of the scattering phenomenon are based on a linear elastic model to predict shock wave scattering by a stone, with and without crack present in it. The elastic waves in the stone and the nearby liquid were modeled using a finite difference time domain approach. The subsequent acoustic propagation of the scattered waves into the far-field was calculated using the Helmholtz-Kirchhoff integral. Experimental studies were conducted using a research electrohydraulic lithotripter that produced the same acoustic output as an unmodified Dornier HM3 clinical lithotripter. Artificial stones, made from Ultracal-30 gypsum and acrylic, were used as targets. The stones had cylindrical shape and were positioned co-axially with the lithotripter axis. The scattered wave was measured by focused broadband PVDF hydrophone. It was shown that the size of the stone noticeably changed the signature of the reflected wave. © 2006 American Institute of Physics

    Assessing the mechanism of kidney stone comminution by a lithotripter shock pulse

    No full text
    Comminution of axisymmetric stones by a lithotripter shock wave was studied experimentally and theoretically. In experiments, shock waves were generated by a research electrohydraulic lithotripter modeled after the Dornier HM-3, and stones were made from U-30 cement. Cylindrical stones of various length to diameter ratios, stones of conical shape, and stones with artificial cracks were studied. In other cases, baffles to block specific waves that contribute to spallation or squeezing were used, and glycerol was used to suppress cavitation. The theory was based on the elasticity equations for an isotropic medium. The equations were written in finite differences and integrated numerically. Maximum compression, tensile and shear stresses were predicted depending on the stone shape and side-surface condition in order to investigate the importance of the stone geometry. It is shown that the theoretical model used explains the observed position of a crack in a stone. The theory also predicts the efficiency of stone fragmentation depending on its shape and size, as well as on the presence of cracks on the stone surface and baffles near the stone. © 2005 American Institute of Physics

    New devices and old pitfalls in shock wave therapy

    No full text
    Shock waves are now used to treat a variety of musculoskeletal indications and the worldwide demand for shock wave therapy (SWT) is growing rapidly. It is a concern that very little is known about the mechanisms of action of shock waves in SWT. The technology for SWT devices is little changed from that of shock wave lithotripters developed for the treatment of urinary stones. SWT devices are engineered on the same acoustics principles as lithotripters, but the targets of therapy for SWT and shock wave lithotripsy (SWL) are altogether different. For SWT to achieve its potential as a beneficial treatment modality it will be necessary to determine precisely how SWT shock waves interact with biological targets. In addition, for SWT to evolve, the future design of these devices should be approached with caution, and lithotripsy may serve as a useful model. Indeed, there is a great deal to be learned from the basic research that has guided the development of SWL. © 2006 American Institute of Physics

    Effect of overpressure and pulse repetition frequency on cavitation in shock wave lithotripsy.

    No full text
    Cavitation appears to contribute to tissue injury in lithotripsy. Reports have shown that increasing pulse repetition frequency [(PRF) 0.5-100 Hz] increases tissue damage and increasing static pressure (1-3 bar) reduces cell damage without decreasing stone comminution. Our hypothesis is that overpressure or slow PRF causes unstabilized bubbles produced by one shock pulse to dissolve before they nucleate cavitation by subsequent shock pulses. The effects of PRF and overpressure on bubble dynamics and lifetimes were studied experimentally with passive cavitation detection, high-speed photography, and B-mode ultrasound and theoretically. Overpressure significantly reduced calculated (100-2 s) and measured (55-0.5 s) bubble lifetimes. At 1.5 bar static pressure, a dense bubble cluster was measured with clinically high PRF (2-3 Hz) and a sparse cluster with clinically low PRF (0.5-1 Hz), indicating bubble lifetimes of 0.5-1 s, consistent with calculations. In contrast to cavitation in water, high-speed photography showed that overpressure did not suppress cavitation of bubbles stabilized on a cracked surface. These results suggest that a judicious use of overpressure and PRF in lithotripsy could reduce cavitation damage of tissue while maintaining cavitation comminution of stones

    Advantage of a broad focal zone in SWL: Synergism between squeezing and shear

    No full text
    Objective: The focal zone width appears to be a critical factor in lithotripsy. Narrow focus machines have a higher occurrence of adverse effects, and arguably no greater comminution efficiency. Manufacturers have introduced new machines and upgrades to broaden the focus. Still, little data exists on how focal width plays a role in stone fracture. Thus, our aim was to determine if focal width interacts with established mechanisms known to contribute to stone fracture. Method: A series of experiments were undertaken with changes made to the stone in an effort to determine which is most important, the shock wave (SW) reflected from the back end of the stone (spallation), the SW ringing the stone (squeezing), the shear wave generated at surface of the stone and concentrated in the bulk of it (shear), or SWs generated from bubble collapse (cavitation). Shock waves were generated by a Dornier HM3-style lithotripter, and stones were made from U30 cement. Baffles were used to block specific waves that contribute to spallation, shear, or squeezing, and glycerol was used to suppress cavitation. Numerical simulation and high-speed imaging allowed for visualization of specific waves as they traveled within the stone. Results: For brevity, one result is explained. A reflective baffle was placed around the front edge of a cylindrical stone. The proximal baffle prevented squeezing by preventing the SW from traveling over the stone, but permitted the SW entering the stone through the proximal face and did not affect the other mechanisms. The distal baffle behaved the same as no baffle. The proximal baffle dramatically reduced the stress, and the stone did not break (stone broke after 45±10 SWs without the baffle and did not break after 400 SWs when the experiment stopped). The result implies that since removing squeezing halted comminution, squeezing is dominant. However, there is much more to the story. For example, if the cylindrical stone was pointed, it broke with the point on the distal end but not with the point on the proximal end. In both cases, squeezing was the same, so if squeezing were dominant, both stones should have broken. But the pointed front edge prevents the shear wave. The squeezing wave and its product - the shear wave - are both needed and work synergistically in a way explained by the model. Conclusions: A broad focus enhances the synergism of squeezing and shear waves without altering cavitation's effects, and thus accelerates stone fracture in SWL. © 2007 American Institute of Physics

    Interactions of cavitation bubbles observed by high-speed imaging in shock wave lithotripsy

    No full text
    A multi-frame high-speed photography was used to investigate the dynamics of cavitation bubbles induced by a passage of a lithotripter shock wave in a water tank. Solitary bubbles in the free field each radiated a shock wave upon collapse, and typically emitted a micro-jet on the rebound following initial collapse. For bubbles in clouds, emitted jets were directed toward neighboring bubbles and could break the spherical symmetry of the neighboring bubbles before they in turn collapsed. Bubbles at the periphery of a cluster underwent collapse before the bubbles at the center. Observations with high-speed imaging confirm previous predictions that bubbles in a cavitation cloud do not cycle independently of one another but instead interact as a dynamic bubble cluster. © 2006 American Institute of Physics
    corecore