49 research outputs found
The Use of Polarization Filters to Detect the Edge of the Descemetās Stripping Automated Endothelial Keratoplasty(DSAEK) Graft
To report the technique of combining the two different polarization filters to detect the flap edge of the corneoscleral tissue before trephining the Descemet's stripping automated endothelial keratoplasty (DSAEK) tissue.
A human DSAEK donor tissue was prepared with mechanical microkeratome and the tissue on the cutting block was brought under the microscope. The liner, circular, or the combination of these two polarization filters was placed between the tissue and the microscope. The tissue images were taken with digital camera under either of 3 settings.
The combination of circular and linear polarization filters enabled us to recognize the edge of the flap more easily than others.
This simple system with polarization filters was effective in clear visualization of the flap edge during DSAEK tissue preparation. These features may significantly enhance safety of various surgical procedures, in addition to DSAEK tissue preparation
Subconjunctival Air Leakage After Descemet's Stripping Automated Endothelial Keratoplasty(DSAEK) in a Post-Trabeculectomy Eye
Subconjunctival Emphysema After Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK)
DSAEK has recently evolved as a preferred method in place of PKP. After DSAEK, we experienced subconjunctival emphysema, decreased air bubble in the AC and low IOP. This could lead to complications, higher rate of dislocation or infection. We should control the wound closure with suture when in doubt
Strategies for replacing non-invasive brain stimulation sessions: recommendations for designing neurostimulation clinical trials
AI is a viable alternative to high throughput screening: a 318-target study
: High throughput screening (HTS) is routinely used to identify bioactive small molecules. This requires physical compounds, which limits coverage of accessible chemical space. Computational approaches combined with vast on-demand chemical libraries can access far greater chemical space, provided that the predictive accuracy is sufficient to identify useful molecules. Through the largest and most diverse virtual HTS campaign reported to date, comprising 318 individual projects, we demonstrate that our AtomNetĀ® convolutional neural network successfully finds novel hits across every major therapeutic area and protein class. We address historical limitations of computational screening by demonstrating success for target proteins without known binders, high-quality X-ray crystal structures, or manual cherry-picking of compounds. We show that the molecules selected by the AtomNetĀ® model are novel drug-like scaffolds rather than minor modifications to known bioactive compounds. Our empirical results suggest that computational methods can substantially replace HTS as the first step of small-molecule drug discovery
Recommended from our members
Topical Ocular Povidone-Iodine as an Adjunctive Preventative Practice in the Era of COVID-19
Ophthalmologists and patients have an inherent increased risk for transmission of SARS-CoV-2. The human ocular surface expresses receptors and enzymes facilitating transmission of SARS-CoV-2. Personal protective equipment alone provides incomplete protection. Adjunctive topical ocular, nasal, and oral antisepsis with povidone iodine bolsters personal protective equipment in prevention of provider-patient transmission of SARS-CoV-2 in ophthalmology
Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens
A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful
Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens
A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful