49 research outputs found

    The Use of Polarization Filters to Detect the Edge of the Descemetā€™s Stripping Automated Endothelial Keratoplasty(DSAEK) Graft

    Get PDF
    To report the technique of combining the two different polarization filters to detect the flap edge of the corneoscleral tissue before trephining the Descemet's stripping automated endothelial keratoplasty (DSAEK) tissue. A human DSAEK donor tissue was prepared with mechanical microkeratome and the tissue on the cutting block was brought under the microscope. The liner, circular, or the combination of these two polarization filters was placed between the tissue and the microscope. The tissue images were taken with digital camera under either of 3 settings. The combination of circular and linear polarization filters enabled us to recognize the edge of the flap more easily than others. This simple system with polarization filters was effective in clear visualization of the flap edge during DSAEK tissue preparation. These features may significantly enhance safety of various surgical procedures, in addition to DSAEK tissue preparation

    Subconjunctival Emphysema After Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK)

    Get PDF
    DSAEK has recently evolved as a preferred method in place of PKP. After DSAEK, we experienced subconjunctival emphysema, decreased air bubble in the AC and low IOP. This could lead to complications, higher rate of dislocation or infection. We should control the wound closure with suture when in doubt

    AI is a viable alternative to high throughput screening: a 318-target study

    Get PDF
    : High throughput screening (HTS) is routinely used to identify bioactive small molecules. This requires physical compounds, which limits coverage of accessible chemical space. Computational approaches combined with vast on-demand chemical libraries can access far greater chemical space, provided that the predictive accuracy is sufficient to identify useful molecules. Through the largest and most diverse virtual HTS campaign reported to date, comprising 318 individual projects, we demonstrate that our AtomNetĀ® convolutional neural network successfully finds novel hits across every major therapeutic area and protein class. We address historical limitations of computational screening by demonstrating success for target proteins without known binders, high-quality X-ray crystal structures, or manual cherry-picking of compounds. We show that the molecules selected by the AtomNetĀ® model are novel drug-like scaffolds rather than minor modifications to known bioactive compounds. Our empirical results suggest that computational methods can substantially replace HTS as the first step of small-molecule drug discovery

    Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    No full text
    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful

    Spontaneous Scleral Perforation of an Anterior Chamber Intraocular Lens

    No full text
    A routine eye examination of a 69-year-old man revealed a scleral perforation of one of the haptics of the anterior chamber intraocular lens (AC IOL) which had been implanted many years ago. The patient was asymptomatic with good visual acuity. His history was negative for any trauma, eye rubbing, topical corticosteroid use, or autoimmune disease. The horizontal and vertical white-to-white diameters of the cornea in the right eye were 11.5 and 10.5 mm, respectively. Anterior segment optical coherence tomography showed the anterior chamber length to be 12.28 mm horizontally and 10.63 mm vertically. The patient underwent an IOL exchange, and the length of the explanted AC IOL was measured to be 12 mm. We speculate that the AC IOL, which was vertically aligned, was oversized. This case demonstrates the need for proper sizing and positioning of an AC IOL. In complex cases where AC IOL may be used, measuring the horizontal and vertical lengths of the anterior chamber by anterior segment optical coherence tomography prior to surgery may be useful
    corecore