16 research outputs found

    Serum High-Sensitivity Cardiac Troponin T Is a Significant Biomarker of Left-Ventricular Diastolic Dysfunction in Subjects with Non-Diabetic Chronic Kidney Disease

    Get PDF
    Background: Chronic kidney disease (CKD) is associated with left-ventricular (LV) diastolic dysfunction (LVDD) which progresses to diastolic heart failure. However, biomarkers predicting LVDD in patients with CKD are largely unknown. Methods: In 93 patients with non-diabetic CKD, the relationships among echocardiography, high-sensitivity cardiac troponin T (hs-cTnT), B-type natriuretic peptide (BNP), and renal function were evaluated. LV mass index, peak early diastolic mitral filling velocity (E), peak early diastolic mitral annular velocity (E′), and E/E′ were recorded. Results: The E′ values were significantly decreased and E/E′, BNP, and hs-cTnT increased with increasing CKD stage. The CKD patients with LVDD with E′ Conclusions: These data suggest that hs-cTnT may be a useful biomarker of LVDD in non- diabetic CKD patients

    Dose distribution of intensity-modulated proton therapy with and without a multi-leaf collimator for the treatment of maxillary sinus cancer: a comparative effectiveness study.

    Get PDF
    BACKGROUND: Severe complications, such as eye damage and dysfunciton of salivary glands, have been reported after radiotherapy among patients with head and neck cancer. Complications such as visual impairment have also been reported after proton therapy with pencil beam scanning (PBS). In the case of PBS, collimation can sharpen the penumbra towards surrounding normal tissue in the low energy region of the proton beam. In the current study, we examined how much the dose to the normal tissue was reduced by when intensity-modulated proton therapy (IMPT) was performed using a multi-leaf collimator (MLC) for patients with maxillary sinus cancer. METHODS: Computed tomography findings of 26 consecutive patients who received photon therapy at Okayama University Hospital were used in this study. We compared D2% of the region of interest (ROI; ROI-D2%) and the mean dose of ROI (ROI-mean) with and without the use of an MLC. The organs at risk (OARs) were the posterior retina, lacrimal gland, eyeball, and parotid gland. IMPT was performed for all patients. The spot size was approximately 5-6 mm at the isocenter. The collimator margin was calculated by enlarging the maximum outline of the target from the beam's eye view and setting the margin to 6 mm. All plans were optimized with the same parameters. RESULTS: The mean of ROI-D2% for the ipsilateral optic nerve was significantly reduced by 0.48 Gy, and the mean of ROI-mean for the ipsilateral optic nerve was significantly reduced by 1.04 Gy. The mean of ROI-mean to the optic chiasm was significantly reduced by 0.70 Gy. The dose to most OARs and the planning at risk volumes were also reduced. CONCLUSIONS: Compared with the plan involving IMPT without an MLC, in the dose plan involving IMPT using an MLC for maxillary sinus cancer, the dose to the optic nerve and optic chiasm were significantly reduced, as measured by the ROI-D2% and the ROI-mean. These findings demonstrate that the use of an MLC during IMPT for maxillary sinus cancer may be useful for preserving vision and preventing complications

    New field‑in‑field with two reference points method for whole breast radiotherapy: Dosimetric analysis and radiation‑induced skin toxicities assessment

    Get PDF
    The usefulness of the field‑in‑field with two reference points (FIF w/ 2RP) method, in which the dose reference points are set simultaneously at two positions in the irradiation field and the high‑dose range is completely eliminated, was examined in the present study with the aim of decreasing acute skin toxicity in adjuvant breast radiotherapy (RT). A total of 573 patients with breast cancer who underwent postoperative whole breast RT were classified into 178 cases with wedge (W) method, 142 cases with field‑in‑field without 2 reference points (FIF w/o 2RP) method and 253 cases with FIF w/ 2RP method. Using the FIF w/ 2RP method, the high‑dose range was the lowest among the three irradiation methods. The planning target volume (PTV) V105% and the breast PTV for evaluation (BPe) V105% decreased to 0.09 and 0.10%, respectively. The FIF w/ 2RP method vs. the FIF w/o 2RP method had a strong association (η) with PTV V105% (η=0.79; P<0.001) and BPe V105% (η=0.76; P<0.001). The FIF w/ 2RP method had a significant impact on lowering the skin toxicity grade in weeks 3 and 4, and increasing the occurrence of skin toxicity grade 0. The FIF w/ 2RP method vs. the W method had a moderate association with skin toxicity grade at week 3 (η=0.49; P<0.001). Using the FIF w/ 2RP method, the high‑dose range V105% of the target decreased to 0%, and skin adverse events were decreased in conjunction. For patients with early‑stage breast cancer, particularly patients with relatively small‑sized breasts, the FIF w/ 2RP method may be an optimal irradiation method

    Investigation into the Effect of Breast Volume on Irradiation Dose Distribution in Asian Women with Breast Cancer

    Get PDF
    Reports on irradiation dose distribution in breast cancer radiotherapy with sufficient sample size are limited in Asian patients. Elucidating dose distribution in Asian patients is particularly important as their breast volume differs compared to patients in Europe and North America. Here, we examined dose distribution in the irradiation field relative to breast volume for three irradiation methods historically used in our facility. We investigated the influence of breast volume on each irradiation method for Asian women. A total of 573 women with early-stage breast cancer were treated with breast-conserving surgery and adjuvant radiotherapy. Three methods were compared: wedge (W), field-in-field (FIF), and wedge-field-in-field (W-FIF). In patients with small breast volume, FIF decreased low- and high-dose areas within the planning target volume, and increased optimal dose area more than W. In patients with medium and large breast volumes, FIF decreased high-dose area more than W. The absolute values of correlation coefficients of breast volume to low-, optimal-, and high-dose areas and mean dose were significantly lower in FIF than in W. The correlation coefficients of V107% were 0.00 and 0.28 for FIF and W, respectively. FIF is an excellent irradiation method that is less affected by breast volume than W in Asian breast cancer patients
    corecore